From: Arnd Bergmann <[email protected]>
Without this, a g12a-only config produces a link error:
aarch64-linux-ld: drivers/clk/meson/g12a.o:(.data+0xcb68): undefined reference to `meson_vid_pll_div_ro_ops'
Fixes: 085a4ea93d54 ("clk: meson: g12a: add peripheral clock controller")
Signed-off-by: Arnd Bergmann <[email protected]>
---
drivers/clk/meson/Kconfig | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/clk/meson/Kconfig b/drivers/clk/meson/Kconfig
index 034da203e8e0..9a8a548d839d 100644
--- a/drivers/clk/meson/Kconfig
+++ b/drivers/clk/meson/Kconfig
@@ -110,6 +110,7 @@ config COMMON_CLK_G12A
select COMMON_CLK_MESON_AO_CLKC
select COMMON_CLK_MESON_EE_CLKC
select COMMON_CLK_MESON_CPU_DYNDIV
+ select COMMON_CLK_MESON_VID_PLL_DIV
select MFD_SYSCON
help
Support for the clock controller on Amlogic S905D2, S905X2 and S905Y2
--
2.27.0
On Thu 03 Dec 2020 at 23:26, Arnd Bergmann <[email protected]> wrote:
> From: Arnd Bergmann <[email protected]>
>
> Without this, a g12a-only config produces a link error:
>
> aarch64-linux-ld: drivers/clk/meson/g12a.o:(.data+0xcb68): undefined reference to `meson_vid_pll_div_ro_ops'
>
> Fixes: 085a4ea93d54 ("clk: meson: g12a: add peripheral clock controller")
> Signed-off-by: Arnd Bergmann <[email protected]>
Hi Arnd,
Thanks for sending this fix.
Same change has already been applied:
https://patchwork.kernel.org/project/linux-clk/patch/[email protected]/
It was part of my last PR to Stephen
Jerome
> ---
> drivers/clk/meson/Kconfig | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/drivers/clk/meson/Kconfig b/drivers/clk/meson/Kconfig
> index 034da203e8e0..9a8a548d839d 100644
> --- a/drivers/clk/meson/Kconfig
> +++ b/drivers/clk/meson/Kconfig
> @@ -110,6 +110,7 @@ config COMMON_CLK_G12A
> select COMMON_CLK_MESON_AO_CLKC
> select COMMON_CLK_MESON_EE_CLKC
> select COMMON_CLK_MESON_CPU_DYNDIV
> + select COMMON_CLK_MESON_VID_PLL_DIV
> select MFD_SYSCON
> help
> Support for the clock controller on Amlogic S905D2, S905X2 and S905Y2