2022-08-30 19:25:42

by Farber, Eliav

[permalink] [raw]
Subject: [PATCH v3 13/19] hwmon: (mr75203) modify the temperature equation according to series 5 datasheet

Modify the equation and coefficients used to convert the digital output
to temperature according to series 5 of the Moortec Embedded Temperature
Sensor (METS) datasheet:
T = G + H * (n / cal5 - 0.5) + J * F

Where:
*) G = 60, H = 200, cal5 = 4094, J = -0.1.
*) F = frequency clock in MHz.
*) n is the digital output.

In code, the G, H and J coefficients are multiplied by a factor of 1000
to get the temperature in milli-Celsius.
Final result is clamped in case it exceeds min/max thresholds.

Change is done since it is not clear where the current equation and
coefficients came from.

Signed-off-by: Eliav Farber <[email protected]>
---
V3 -> V2:
- Protect from overflow.
- Add temperature clamping.
- Add better documentation.

drivers/hwmon/mr75203.c | 29 +++++++++++++++++++++--------
1 file changed, 21 insertions(+), 8 deletions(-)

diff --git a/drivers/hwmon/mr75203.c b/drivers/hwmon/mr75203.c
index d1f090a9baac..5b8ca1ee4a54 100644
--- a/drivers/hwmon/mr75203.c
+++ b/drivers/hwmon/mr75203.c
@@ -103,13 +103,17 @@

#define PVT_POLL_DELAY_US 20
#define PVT_POLL_TIMEOUT_US 20000
-#define PVT_H_CONST 100000
-#define PVT_CAL5_CONST 2047
-#define PVT_G_CONST 40000
+#define PVT_H_CONST 200000
+#define PVT_G_CONST 60000
+#define PVT_J_CONST -100
+#define PVT_CAL5_CONST 4094
#define PVT_CONV_BITS 10
#define PVT_N_CONST 90
#define PVT_R_CONST 245805

+#define PVT_TEMP_MIN -40000
+#define PVT_TEMP_MAX 125000
+
#define PRE_SCALER_X1 1
#define PRE_SCALER_X2 2

@@ -157,13 +161,24 @@ static umode_t pvt_is_visible(const void *data, enum hwmon_sensor_types type,
return 0;
}

+static long pvt_calc_temp(struct pvt_device *pvt, u32 nbs)
+{
+ /*
+ * Convert the register value to degrees centigrade temperature:
+ * T = G + H * (n / cal5 - 0.5) + J * F
+ */
+ s64 tmp = PVT_G_CONST + PVT_H_CONST * (s64)nbs / PVT_CAL5_CONST -
+ PVT_H_CONST / 2 + PVT_J_CONST * (s64)pvt->ip_freq / HZ_PER_MHZ;
+
+ return clamp_val(tmp, PVT_TEMP_MIN, PVT_TEMP_MAX);
+}
+
static int pvt_read_temp(struct device *dev, u32 attr, int channel, long *val)
{
struct pvt_device *pvt = dev_get_drvdata(dev);
struct regmap *t_map = pvt->t_map;
u32 stat, nbs;
int ret;
- u64 tmp;

switch (attr) {
case hwmon_temp_input:
@@ -184,9 +199,7 @@ static int pvt_read_temp(struct device *dev, u32 attr, int channel, long *val)
* Convert the register value to
* degrees centigrade temperature
*/
- tmp = nbs * PVT_H_CONST;
- do_div(tmp, PVT_CAL5_CONST);
- *val = tmp - PVT_G_CONST - pvt->ip_freq;
+ *val = pvt_calc_temp(pvt, nbs);

return 0;
default:
@@ -311,7 +324,7 @@ static int pvt_init(struct pvt_device *pvt)
(key >> 1) << CLK_SYNTH_HI_SFT |
(key >> 1) << CLK_SYNTH_HOLD_SFT | CLK_SYNTH_EN;

- pvt->ip_freq = sys_freq * 100 / (key + 2);
+ pvt->ip_freq = clk_get_rate(pvt->clk) / (key + 2);

if (t_num) {
ret = regmap_write(t_map, SDIF_SMPL_CTRL, 0x0);
--
2.37.1


2022-08-31 12:32:50

by Andy Shevchenko

[permalink] [raw]
Subject: Re: [PATCH v3 13/19] hwmon: (mr75203) modify the temperature equation according to series 5 datasheet

On Tue, Aug 30, 2022 at 07:22:06PM +0000, Eliav Farber wrote:
> Modify the equation and coefficients used to convert the digital output
> to temperature according to series 5 of the Moortec Embedded Temperature
> Sensor (METS) datasheet:
> T = G + H * (n / cal5 - 0.5) + J * F
>
> Where:
> *) G = 60, H = 200, cal5 = 4094, J = -0.1.
> *) F = frequency clock in MHz.
> *) n is the digital output.
>
> In code, the G, H and J coefficients are multiplied by a factor of 1000
> to get the temperature in milli-Celsius.
> Final result is clamped in case it exceeds min/max thresholds.
>
> Change is done since it is not clear where the current equation and

not clear -> unclear

> coefficients came from.

...

> +#define PVT_TEMP_MIN -40000
> +#define PVT_TEMP_MAX 125000

Unit suffix? _mC perhaps would be enough.

--
With Best Regards,
Andy Shevchenko


2022-09-01 12:31:19

by Farber, Eliav

[permalink] [raw]
Subject: Re: [PATCH v3 13/19] hwmon: (mr75203) modify the temperature equation according to series 5 datasheet

On 8/31/2022 3:06 PM, Andy Shevchenko wrote:
> On Tue, Aug 30, 2022 at 07:22:06PM +0000, Eliav Farber wrote:
>> Modify the equation and coefficients used to convert the digital output
>> to temperature according to series 5 of the Moortec Embedded Temperature
>> Sensor (METS) datasheet:
>> T = G + H * (n / cal5 - 0.5) + J * F
>>
>> Where:
>> *) G = 60, H = 200, cal5 = 4094, J = -0.1.
>> *) F = frequency clock in MHz.
>> *) n is the digital output.
>>
>> In code, the G, H and J coefficients are multiplied by a factor of 1000
>> to get the temperature in milli-Celsius.
>> Final result is clamped in case it exceeds min/max thresholds.
>>
>> Change is done since it is not clear where the current equation and
>
> not clear -> unclear
>
Fixed.

>> coefficients came from.
>
> ...
>
>> +#define PVT_TEMP_MIN         -40000
>> +#define PVT_TEMP_MAX         125000
>
> Unit suffix? _mC perhaps would be enough.

Fixed. Added _mC suffix as you suggested.

--
Thanks, Eliav