2023-05-01 22:47:28

by Judith Mendez

[permalink] [raw]
Subject: [PATCH v4 1/4] dt-bindings: net: can: Add poll-interval for MCAN

On AM62x SoC, MCANs on MCU domain do not have hardware interrupt
routed to A53 Linux, instead they will use software interrupt by
hrtimer. To enable timer method, interrupts should be optional so
remove interrupts property from required section and introduce
poll-interval property.

Signed-off-by: Judith Mendez <[email protected]>
---
Changelog:
v3:
1. Move binding patch to first in series
2. Update description for poll-interval
3. Add oneOf to specify using interrupts/interrupt-names or poll-interval
4. Fix example property: add comment below 'example'

v2:
1. Add poll-interval property to enable timer polling method
2. Add example using poll-interval property

.../bindings/net/can/bosch,m_can.yaml | 36 +++++++++++++++++--
1 file changed, 34 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
index 67879aab623b..c024ee49962c 100644
--- a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
+++ b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
@@ -14,6 +14,13 @@ maintainers:
allOf:
- $ref: can-controller.yaml#

+oneOf:
+ - required:
+ - interrupts
+ - interrupt-names
+ - required:
+ - poll-interval
+
properties:
compatible:
const: bosch,m_can
@@ -40,6 +47,14 @@ properties:
- const: int1
minItems: 1

+ poll-interval:
+ $ref: /schemas/types.yaml#/definitions/flag
+ description: Enable hrtimer polling method for an M_CAN device.
+ If this property is defined in MCAN node, it tells the driver to
+ enable polling method for an MCAN device. If for an MCAN device,
+ hardware interrupt is found and hrtimer polling method is enabled,
+ the driver will use hardware interrupt method.
+
clocks:
items:
- description: peripheral clock
@@ -122,8 +137,6 @@ required:
- compatible
- reg
- reg-names
- - interrupts
- - interrupt-names
- clocks
- clock-names
- bosch,mram-cfg
@@ -132,6 +145,7 @@ additionalProperties: false

examples:
- |
+ // Example with interrupts
#include <dt-bindings/clock/imx6sx-clock.h>
can@20e8000 {
compatible = "bosch,m_can";
@@ -149,4 +163,22 @@ examples:
};
};

+ - |
+ // Example with timer polling
+ #include <dt-bindings/clock/imx6sx-clock.h>
+ can@20e8000 {
+ compatible = "bosch,m_can";
+ reg = <0x020e8000 0x4000>, <0x02298000 0x4000>;
+ reg-names = "m_can", "message_ram";
+ poll-interval;
+ clocks = <&clks IMX6SX_CLK_CANFD>,
+ <&clks IMX6SX_CLK_CANFD>;
+ clock-names = "hclk", "cclk";
+ bosch,mram-cfg = <0x0 0 0 32 0 0 0 1>;
+
+ can-transceiver {
+ max-bitrate = <5000000>;
+ };
+ };
+
...
--
2.17.1


2023-05-05 21:40:34

by Rob Herring (Arm)

[permalink] [raw]
Subject: Re: [PATCH v4 1/4] dt-bindings: net: can: Add poll-interval for MCAN

On Mon, May 01, 2023 at 05:46:21PM -0500, Judith Mendez wrote:
> On AM62x SoC, MCANs on MCU domain do not have hardware interrupt
> routed to A53 Linux, instead they will use software interrupt by
> hrtimer. To enable timer method, interrupts should be optional so
> remove interrupts property from required section and introduce
> poll-interval property.
>
> Signed-off-by: Judith Mendez <[email protected]>
> ---
> Changelog:
> v3:
> 1. Move binding patch to first in series
> 2. Update description for poll-interval
> 3. Add oneOf to specify using interrupts/interrupt-names or poll-interval
> 4. Fix example property: add comment below 'example'
>
> v2:
> 1. Add poll-interval property to enable timer polling method
> 2. Add example using poll-interval property
>
> .../bindings/net/can/bosch,m_can.yaml | 36 +++++++++++++++++--
> 1 file changed, 34 insertions(+), 2 deletions(-)
>
> diff --git a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
> index 67879aab623b..c024ee49962c 100644
> --- a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
> +++ b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
> @@ -14,6 +14,13 @@ maintainers:
> allOf:
> - $ref: can-controller.yaml#
>
> +oneOf:
> + - required:
> + - interrupts
> + - interrupt-names
> + - required:
> + - poll-interval

Move this next to 'required'.

> +
> properties:
> compatible:
> const: bosch,m_can
> @@ -40,6 +47,14 @@ properties:
> - const: int1
> minItems: 1
>
> + poll-interval:
> + $ref: /schemas/types.yaml#/definitions/flag

This is a common property already defined as a uint32. You shouldn't
define a new type.

A flag doesn't even make sense. If that's all you need, then just enable
polling if no interrupt is present.

> + description: Enable hrtimer polling method for an M_CAN device.
> + If this property is defined in MCAN node, it tells the driver to
> + enable polling method for an MCAN device. If for an MCAN device,
> + hardware interrupt is found and hrtimer polling method is enabled,

What's hrtimer? (Don't put Linuxisms in bindings)

> + the driver will use hardware interrupt method.
> +
> clocks:
> items:
> - description: peripheral clock
> @@ -122,8 +137,6 @@ required:
> - compatible
> - reg
> - reg-names
> - - interrupts
> - - interrupt-names
> - clocks
> - clock-names
> - bosch,mram-cfg
> @@ -132,6 +145,7 @@ additionalProperties: false
>
> examples:
> - |
> + // Example with interrupts
> #include <dt-bindings/clock/imx6sx-clock.h>
> can@20e8000 {
> compatible = "bosch,m_can";
> @@ -149,4 +163,22 @@ examples:
> };
> };
>
> + - |
> + // Example with timer polling
> + #include <dt-bindings/clock/imx6sx-clock.h>
> + can@20e8000 {
> + compatible = "bosch,m_can";
> + reg = <0x020e8000 0x4000>, <0x02298000 0x4000>;
> + reg-names = "m_can", "message_ram";
> + poll-interval;
> + clocks = <&clks IMX6SX_CLK_CANFD>,
> + <&clks IMX6SX_CLK_CANFD>;
> + clock-names = "hclk", "cclk";
> + bosch,mram-cfg = <0x0 0 0 32 0 0 0 1>;
> +
> + can-transceiver {
> + max-bitrate = <5000000>;
> + };
> + };
> +
> ...
> --
> 2.17.1
>

2023-05-09 12:42:35

by Marc Kleine-Budde

[permalink] [raw]
Subject: Re: [PATCH v4 1/4] dt-bindings: net: can: Add poll-interval for MCAN

On 05.05.2023 16:29:48, Rob Herring wrote:
> On Mon, May 01, 2023 at 05:46:21PM -0500, Judith Mendez wrote:
> > On AM62x SoC, MCANs on MCU domain do not have hardware interrupt
> > routed to A53 Linux, instead they will use software interrupt by
> > hrtimer. To enable timer method, interrupts should be optional so
> > remove interrupts property from required section and introduce
> > poll-interval property.
> >
> > Signed-off-by: Judith Mendez <[email protected]>
> > ---
> > Changelog:
> > v3:
> > 1. Move binding patch to first in series
> > 2. Update description for poll-interval
> > 3. Add oneOf to specify using interrupts/interrupt-names or poll-interval
> > 4. Fix example property: add comment below 'example'
> >
> > v2:
> > 1. Add poll-interval property to enable timer polling method
> > 2. Add example using poll-interval property
> >
> > .../bindings/net/can/bosch,m_can.yaml | 36 +++++++++++++++++--
> > 1 file changed, 34 insertions(+), 2 deletions(-)
> >
> > diff --git a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
> > index 67879aab623b..c024ee49962c 100644
> > --- a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
> > +++ b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
> > @@ -14,6 +14,13 @@ maintainers:
> > allOf:
> > - $ref: can-controller.yaml#
> >
> > +oneOf:
> > + - required:
> > + - interrupts
> > + - interrupt-names
> > + - required:
> > + - poll-interval
>
> Move this next to 'required'.
>
> > +
> > properties:
> > compatible:
> > const: bosch,m_can
> > @@ -40,6 +47,14 @@ properties:
> > - const: int1
> > minItems: 1
> >
> > + poll-interval:
> > + $ref: /schemas/types.yaml#/definitions/flag
>
> This is a common property already defined as a uint32. You shouldn't
> define a new type.
>
> A flag doesn't even make sense. If that's all you need, then just enable
> polling if no interrupt is present.

Ok, then it's implicit. No IRQs -> polling.

Marc

--
Pengutronix e.K. | Marc Kleine-Budde |
Embedded Linux | https://www.pengutronix.de |
Vertretung Nürnberg | Phone: +49-5121-206917-129 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-9 |


Attachments:
(No filename) (2.34 kB)
signature.asc (499.00 B)
Download all attachments

2023-05-09 17:20:13

by Judith Mendez

[permalink] [raw]
Subject: Re: [PATCH v4 1/4] dt-bindings: net: can: Add poll-interval for MCAN

Hello all,

On 5/9/23 07:27, Marc Kleine-Budde wrote:
> On 05.05.2023 16:29:48, Rob Herring wrote:
>> On Mon, May 01, 2023 at 05:46:21PM -0500, Judith Mendez wrote:
>>> On AM62x SoC, MCANs on MCU domain do not have hardware interrupt
>>> routed to A53 Linux, instead they will use software interrupt by
>>> hrtimer. To enable timer method, interrupts should be optional so
>>> remove interrupts property from required section and introduce
>>> poll-interval property.
>>>
>>> Signed-off-by: Judith Mendez <[email protected]>
>>> ---
>>> Changelog:
>>> v3:
>>> 1. Move binding patch to first in series
>>> 2. Update description for poll-interval
>>> 3. Add oneOf to specify using interrupts/interrupt-names or poll-interval
>>> 4. Fix example property: add comment below 'example'
>>>
>>> v2:
>>> 1. Add poll-interval property to enable timer polling method
>>> 2. Add example using poll-interval property
>>>
>>> .../bindings/net/can/bosch,m_can.yaml | 36 +++++++++++++++++--
>>> 1 file changed, 34 insertions(+), 2 deletions(-)
>>>
>>> diff --git a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
>>> index 67879aab623b..c024ee49962c 100644
>>> --- a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
>>> +++ b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml
>>> @@ -14,6 +14,13 @@ maintainers:
>>> allOf:
>>> - $ref: can-controller.yaml#
>>>
>>> +oneOf:
>>> + - required:
>>> + - interrupts
>>> + - interrupt-names
>>> + - required:
>>> + - poll-interval
>>
>> Move this next to 'required'.
>>
>>> +
>>> properties:
>>> compatible:
>>> const: bosch,m_can
>>> @@ -40,6 +47,14 @@ properties:
>>> - const: int1
>>> minItems: 1
>>>
>>> + poll-interval:
>>> + $ref: /schemas/types.yaml#/definitions/flag
>>
>> This is a common property already defined as a uint32. You shouldn't
>> define a new type.
>>
>> A flag doesn't even make sense. If that's all you need, then just enable
>> polling if no interrupt is present.
>
> Ok, then it's implicit. No IRQs -> polling.

Ok, will send out a v5 with these updates. Thanks.

regards,
Judith