Switches from mv88e6250 family (the marketing name - "Link Street",
including mv88e6020 and mv88e6071) need the possibility to setup the
maximal frame size, as they support frames up to 2048 bytes.
Signed-off-by: Lukasz Majewski <[email protected]>
---
Changes for v6:
- New patch
Changes for v7:
- Update commit message
---
drivers/net/dsa/mv88e6xxx/chip.c | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/net/dsa/mv88e6xxx/chip.c b/drivers/net/dsa/mv88e6xxx/chip.c
index 64a2f2f83735..b5e43dd40431 100644
--- a/drivers/net/dsa/mv88e6xxx/chip.c
+++ b/drivers/net/dsa/mv88e6xxx/chip.c
@@ -5043,6 +5043,7 @@ static const struct mv88e6xxx_ops mv88e6250_ops = {
.avb_ops = &mv88e6352_avb_ops,
.ptp_ops = &mv88e6250_ptp_ops,
.phylink_get_caps = mv88e6250_phylink_get_caps,
+ .set_max_frame_size = mv88e6185_g1_set_max_frame_size,
};
static const struct mv88e6xxx_ops mv88e6290_ops = {
--
2.20.1
On Tue, May 23, 2023 at 04:29:10PM +0200, Lukasz Majewski wrote:
> Switches from mv88e6250 family (the marketing name - "Link Street",
> including mv88e6020 and mv88e6071) need the possibility to setup the
> maximal frame size, as they support frames up to 2048 bytes.
>
> Signed-off-by: Lukasz Majewski <[email protected]>
Adding this function doesn't allow the "possibility" for a larger frame
size. Adding it changes the value returned from mv88e6xxx_get_max_mtu()
to be a larger frame size, so all switches that make use of
mv88e6250_ops will be expected to support this larger frame size. Do
we know whether that is true?
There were patches floating about a while ago that specified the
maximum size in struct mv88e6xxx_info, but it seems those died a death.
--
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 80Mbps down 10Mbps up. Decent connectivity at last!
Also, subject line should be "net: dsa: ..."
--
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 80Mbps down 10Mbps up. Decent connectivity at last!
On Wed, May 24, 2023 at 02:06:36PM +0200, Lukasz Majewski wrote:
> Hi Russell,
>
> > Also, subject line should be "net: dsa: ..."
> >
>
> Ok, I will correct that subject line.
Also, please use "mv88e6xxx" rather than "marvell" - consistency in the
subject lines, particularly when referring to a part of the kernel tree
is desirable.
--
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 80Mbps down 10Mbps up. Decent connectivity at last!
Hi Russell,
> Also, subject line should be "net: dsa: ..."
>
Ok, I will correct that subject line.
Best regards,
Lukasz Majewski
--
DENX Software Engineering GmbH, Managing Director: Erika Unter
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: [email protected]
Hi Russell,
> On Tue, May 23, 2023 at 04:29:10PM +0200, Lukasz Majewski wrote:
> > Switches from mv88e6250 family (the marketing name - "Link Street",
> > including mv88e6020 and mv88e6071) need the possibility to setup the
> > maximal frame size, as they support frames up to 2048 bytes.
> >
> > Signed-off-by: Lukasz Majewski <[email protected]>
>
> Adding this function doesn't allow the "possibility" for a larger
> frame size. Adding it changes the value returned from
> mv88e6xxx_get_max_mtu() to be a larger frame size, so all switches
> that make use of mv88e6250_ops will be expected to support this
> larger frame size. Do we know whether that is true?
>
According to functional specification - the 6070, 6071, 6250, 6020 and
6220 have "Max Frame Size" of 2048 bytes.
The mv88e6xxx_get_max_mtu() now will:
return 1632 - VLAN_ETH_HLEN - EDSA_HLEN - ETH_FCS_LEN;
which is acceptable and safe for this family of chips.
> There were patches floating about a while ago that specified the
> maximum size in struct mv88e6xxx_info, but it seems those died a
> death.
>
Those patches seems to not be strictly required after Vladimir's work.
The v7 provides what I need, so yes - extra patches from v6 can be
discarded.
Best regards,
Lukasz Majewski
--
DENX Software Engineering GmbH, Managing Director: Erika Unter
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: [email protected]