Return-Path: Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S933414AbbFJH6P (ORCPT ); Wed, 10 Jun 2015 03:58:15 -0400 Received: from mail-wg0-f41.google.com ([74.125.82.41]:36541 "EHLO mail-wg0-f41.google.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S933280AbbFJH6H (ORCPT ); Wed, 10 Jun 2015 03:58:07 -0400 From: Lee Jones To: linux-arm-kernel@lists.infradead.org, linux-kernel@vger.kernel.org Cc: kernel@stlinux.com, broonie@kernel.org, lgirdwood@gmail.com, Lee Jones , devicetree@vger.kernel.org Subject: [REBASED 4/5] dt: regulator: pwm-regulator: Re-write bindings Date: Wed, 10 Jun 2015 08:57:52 +0100 Message-Id: <1433923073-907-5-git-send-email-lee.jones@linaro.org> X-Mailer: git-send-email 1.9.1 In-Reply-To: <1433923073-907-1-git-send-email-lee.jones@linaro.org> References: <1433923073-907-1-git-send-email-lee.jones@linaro.org> Sender: linux-kernel-owner@vger.kernel.org List-ID: X-Mailing-List: linux-kernel@vger.kernel.org Content-Length: 3855 Lines: 104 * Add support for continuous-voltage mode * Put more meat on the bones with regards to voltage-table mode * Sort out formatting for ease of consumption Cc: devicetree@vger.kernel.org Signed-off-by: Lee Jones --- .../bindings/regulator/pwm-regulator.txt | 66 ++++++++++++++++++---- 1 file changed, 54 insertions(+), 12 deletions(-) diff --git a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt index ce91f61..0ae7895 100644 --- a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt +++ b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt @@ -1,27 +1,69 @@ -pwm regulator bindings +Bindings for the Generic PWM Regulator +====================================== + +Currently supports 2 modes of operation: + +voltage-table: When in this mode, a voltage table (See below) of predefined + voltage <=> duty-cycle values must be provided via DT. + Limitations are that the regulator can only operate at the + voltages supplied in the table. Intermediary duty-cycle + values which would normally allow finer grained voltage + selection are ignored and rendered useless. Although more + control is given to the user if the assumptions made in + continuous-voltage mode do not reign true. + +continuous-voltage: This mode uses the regulator's maximum and minimum supplied + voltages specified in the regulator-{min,max}-microvolt + properties to calculate appropriate duty-cycle values. This + allows for a much more fine grained solution when compared + with voltage-table mode above. This solution does make an + assumption that a %50 duty-cycle value will cause the + regulator voltage to run at half way between the supplied + max_uV and min_uV values. Required properties: -- compatible: Should be "pwm-regulator" -- pwms: OF device-tree PWM specification (see PWM binding pwm.txt) -- voltage-table: voltage and duty table, include 2 members in each set of - brackets, first one is voltage(unit: uv), the next is duty(unit: percent) +-------------------- +- compatible: Should be "pwm-regulator" + +- pwms: PWM specification (See: ../pwm/pwm.txt) + +One of these must be provided: +- voltage-table: Voltage and Duty-Cycle table consisting of 2 cells + First cell is voltage in microvolts (uV) + Second cell is duty-cycle in percent (%) + +- max-duty-cycle: Maximum Duty-Cycle value -- this will normally be 255 (0xff) + for an 8 bit PWM device -Any property defined as part of the core regulator binding defined in -regulator.txt can also be used. +If both are provided, the current default is voltage-table mode. -Example: +Any property defined as part of the core regulator binding can also be used. +(See: ../regulator/regulator.txt) + +Continuous Voltage Example: pwm_regulator { compatible = "pwm-regulator; pwms = <&pwm1 0 8448 0>; + regulator-min-microvolt = <1016000>; + regulator-max-microvolt = <1114000>; + regulator-name = "vdd_logic"; + + max-duty-cycle = <255>; /* 8bit PWM */ + }; +Voltage Table Example: + pwm_regulator { + compatible = "pwm-regulator; + pwms = <&pwm1 0 8448 0>; + regulator-min-microvolt = <1016000>; + regulator-max-microvolt = <1114000>; + regulator-name = "vdd_logic"; + + /* Voltage Duty-Cycle */ voltage-table = <1114000 0>, <1095000 10>, <1076000 20>, <1056000 30>, <1036000 40>, <1016000 50>; - - regulator-min-microvolt = <1016000>; - regulator-max-microvolt = <1114000>; - regulator-name = "vdd_logic"; }; -- 1.9.1 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/