Received: by 2002:a25:1985:0:0:0:0:0 with SMTP id 127csp3024703ybz; Mon, 27 Apr 2020 08:40:31 -0700 (PDT) X-Google-Smtp-Source: APiQypLHJZrlNFekU62hfcU3ZQ8I8E2SKJmLCOHoiKiaXkp17rgAayNiZ6qq3PceCHG320wUbzHN X-Received: by 2002:a17:906:359b:: with SMTP id o27mr20604798ejb.282.1588002030990; Mon, 27 Apr 2020 08:40:30 -0700 (PDT) ARC-Seal: i=1; a=rsa-sha256; t=1588002030; cv=none; d=google.com; s=arc-20160816; b=XYUxkWwssYkMhPCUl1U/EDSmN8X1bJ4JNi1A+KoL2q1ar3gzsBe0RQKjg2rveWbCu/ r+BsAFiXiIZei9J6gtECgZlwd6zWa9Dl9nfnANBagHlYg6vDsAqDPyraw22J5nGxa2lN EKF8+yM/IvWoTkpYmwhPDzxMq4E/vlCXvpxJPyNh8b+aLhN+w7UvKMl9h2+J+Oycjpvy PT+40zJVCOEErQbqgfPWsvR//ntftpGkU9n3Jvo2/3C6R5Lbi+8HAN9bkgn5lSzjaVRG mU3fobCO2kPnxWai+0sa3wmglZBd9xuLpbfy7BrKuDpqwAxT13yltztoMThceRipOTfA ZP4Q== ARC-Message-Signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=google.com; s=arc-20160816; h=list-id:precedence:sender:user-agent:in-reply-to :content-disposition:mime-version:references:message-id:subject:cc :to:from:date:dkim-signature; bh=S6+QU/bD7wTmAh7gBgePIUFumQyjAiUTr7PDnaa7Y5E=; b=xFziG6Ik3q86zU2Wtn+k28n9g2V7Qk8sU1LDFxaDzHRlBNdxrJpNuKTN/QYCUJzvYR YRdRnkyLEwiy8TH0x4Q2+jbzOt68oVHQg6QfOkUNVNNgseTPgmyD9nr+P7jCXhEHOw5/ vlf+RIWsdgGAoP2rsGHJXeigtCMZuX3tUlCDujUxAjP9CBs5c81dgFmmMjSNsd1KJFOI ZTuazEdY24Y5gS1g4b1RcOl4fWXrDC3Bn8Mxe/S6X6s3ADZnYfA/6uW/5QV/ozI864R6 OJh+kg0uUk4z8KIg2HCwYJQ4CxaS+58P795nK7y8D+pkVs/nUCoiYwvtPAfXgTrtQJjM TBYA== ARC-Authentication-Results: i=1; mx.google.com; dkim=pass header.i=@redhat.com header.s=mimecast20190719 header.b=XjUAhF3c; spf=pass (google.com: domain of linux-kernel-owner@vger.kernel.org designates 23.128.96.18 as permitted sender) smtp.mailfrom=linux-kernel-owner@vger.kernel.org; dmarc=pass (p=NONE sp=NONE dis=NONE) header.from=redhat.com Return-Path: Received: from vger.kernel.org (vger.kernel.org. [23.128.96.18]) by mx.google.com with ESMTP id q8si8571476ejn.176.2020.04.27.08.40.07; Mon, 27 Apr 2020 08:40:30 -0700 (PDT) Received-SPF: pass (google.com: domain of linux-kernel-owner@vger.kernel.org designates 23.128.96.18 as permitted sender) client-ip=23.128.96.18; Authentication-Results: mx.google.com; dkim=pass header.i=@redhat.com header.s=mimecast20190719 header.b=XjUAhF3c; spf=pass (google.com: domain of linux-kernel-owner@vger.kernel.org designates 23.128.96.18 as permitted sender) smtp.mailfrom=linux-kernel-owner@vger.kernel.org; dmarc=pass (p=NONE sp=NONE dis=NONE) header.from=redhat.com Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1728188AbgD0PiP (ORCPT + 99 others); Mon, 27 Apr 2020 11:38:15 -0400 Received: from us-smtp-delivery-1.mimecast.com ([205.139.110.120]:52718 "EHLO us-smtp-1.mimecast.com" rhost-flags-OK-OK-OK-FAIL) by vger.kernel.org with ESMTP id S1728162AbgD0PiO (ORCPT ); Mon, 27 Apr 2020 11:38:14 -0400 DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=redhat.com; s=mimecast20190719; t=1588001892; h=from:from:reply-to:subject:subject:date:date:message-id:message-id: to:to:cc:cc:mime-version:mime-version:content-type:content-type: in-reply-to:in-reply-to:references:references; bh=S6+QU/bD7wTmAh7gBgePIUFumQyjAiUTr7PDnaa7Y5E=; b=XjUAhF3cXTR+wdmfGxiyUbqkV0onN4Lc90dq8Dw9cY0zPumU2PHwYKb3HaET6g+Ca7xwt8 mQ455HiDNxKRuOnDO76a7FScS0yE0ZkB1/D7h9mzkHzUbfp9OLT/GXV8dWgS7+a1YCEXdm QAg2sC+YPY2by4pGrqyajxS3+sOQcbs= Received: from mimecast-mx01.redhat.com (mimecast-mx01.redhat.com [209.132.183.4]) (Using TLS) by relay.mimecast.com with ESMTP id us-mta-514-RaatyLQqMO2D4ywpEP_U7A-1; Mon, 27 Apr 2020 11:38:10 -0400 X-MC-Unique: RaatyLQqMO2D4ywpEP_U7A-1 Received: from smtp.corp.redhat.com (int-mx03.intmail.prod.int.phx2.redhat.com [10.5.11.13]) (using TLSv1.2 with cipher AECDH-AES256-SHA (256/256 bits)) (No client certificate requested) by mimecast-mx01.redhat.com (Postfix) with ESMTPS id 34D0C1083E80; Mon, 27 Apr 2020 15:38:01 +0000 (UTC) Received: from work-vm (ovpn-114-175.ams2.redhat.com [10.36.114.175]) by smtp.corp.redhat.com (Postfix) with ESMTPS id 3761460C19; Mon, 27 Apr 2020 15:37:46 +0000 (UTC) Date: Mon, 27 Apr 2020 16:37:43 +0100 From: "Dr. David Alan Gilbert" To: Yan Zhao Cc: "Tian, Kevin" , Alex Williamson , "cjia@nvidia.com" , "kvm@vger.kernel.org" , "linux-doc@vger.kernel.org" , "libvir-list@redhat.com" , "Zhengxiao.zx@alibaba-inc.com" , "shuangtai.tst@alibaba-inc.com" , "qemu-devel@nongnu.org" , "kwankhede@nvidia.com" , "eauger@redhat.com" , "corbet@lwn.net" , "Liu, Yi L" , "eskultet@redhat.com" , "Yang, Ziye" , "mlevitsk@redhat.com" , "pasic@linux.ibm.com" , "aik@ozlabs.ru" , "felipe@nutanix.com" , "Ken.Xue@amd.com" , "Zeng, Xin" , "zhenyuw@linux.intel.com" , "dinechin@redhat.com" , "intel-gvt-dev@lists.freedesktop.org" , "Liu, Changpeng" , "berrange@redhat.com" , Cornelia Huck , "linux-kernel@vger.kernel.org" , "Wang, Zhi A" , "jonathan.davies@nutanix.com" , "He, Shaopeng" Subject: Re: [PATCH v5 0/4] introduction of migration_version attribute for VFIO live migration Message-ID: <20200427153743.GK2923@work-vm> References: <20200417104450.2d2f2fa9.cohuck@redhat.com> <20200417095202.GD16688@joy-OptiPlex-7040> <20200417132457.45d91fe3.cohuck@redhat.com> <20200420012457.GE16688@joy-OptiPlex-7040> <20200420165600.4951ae82@w520.home> <20200421023718.GA12111@joy-OptiPlex-7040> <20200422073628.GA12879@joy-OptiPlex-7040> <20200424191049.GU3106@work-vm> <20200426013628.GC12879@joy-OptiPlex-7040> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Disposition: inline In-Reply-To: <20200426013628.GC12879@joy-OptiPlex-7040> User-Agent: Mutt/1.13.4 (2020-02-15) X-Scanned-By: MIMEDefang 2.79 on 10.5.11.13 Sender: linux-kernel-owner@vger.kernel.org Precedence: bulk List-ID: X-Mailing-List: linux-kernel@vger.kernel.org * Yan Zhao (yan.y.zhao@intel.com) wrote: > On Sat, Apr 25, 2020 at 03:10:49AM +0800, Dr. David Alan Gilbert wrote: > > * Yan Zhao (yan.y.zhao@intel.com) wrote: > > > On Tue, Apr 21, 2020 at 08:08:49PM +0800, Tian, Kevin wrote: > > > > > From: Yan Zhao > > > > > Sent: Tuesday, April 21, 2020 10:37 AM > > > > > > > > > > On Tue, Apr 21, 2020 at 06:56:00AM +0800, Alex Williamson wrote: > > > > > > On Sun, 19 Apr 2020 21:24:57 -0400 > > > > > > Yan Zhao wrote: > > > > > > > > > > > > > On Fri, Apr 17, 2020 at 07:24:57PM +0800, Cornelia Huck wrote: > > > > > > > > On Fri, 17 Apr 2020 05:52:02 -0400 > > > > > > > > Yan Zhao wrote: > > > > > > > > > > > > > > > > > On Fri, Apr 17, 2020 at 04:44:50PM +0800, Cornelia Huck wrote: > > > > > > > > > > On Mon, 13 Apr 2020 01:52:01 -0400 > > > > > > > > > > Yan Zhao wrote: > > > > > > > > > > > > > > > > > > > > > This patchset introduces a migration_version attribute under sysfs > > > > > of VFIO > > > > > > > > > > > Mediated devices. > > > > > > > > > > > > > > > > > > > > > > This migration_version attribute is used to check migration > > > > > compatibility > > > > > > > > > > > between two mdev devices. > > > > > > > > > > > > > > > > > > > > > > Currently, it has two locations: > > > > > > > > > > > (1) under mdev_type node, > > > > > > > > > > > which can be used even before device creation, but only for > > > > > mdev > > > > > > > > > > > devices of the same mdev type. > > > > > > > > > > > (2) under mdev device node, > > > > > > > > > > > which can only be used after the mdev devices are created, but > > > > > the src > > > > > > > > > > > and target mdev devices are not necessarily be of the same > > > > > mdev type > > > > > > > > > > > (The second location is newly added in v5, in order to keep > > > > > consistent > > > > > > > > > > > with the migration_version node for migratable pass-though > > > > > devices) > > > > > > > > > > > > > > > > > > > > What is the relationship between those two attributes? > > > > > > > > > > > > > > > > > > > (1) is for mdev devices specifically, and (2) is provided to keep the > > > > > same > > > > > > > > > sysfs interface as with non-mdev cases. so (2) is for both mdev > > > > > devices and > > > > > > > > > non-mdev devices. > > > > > > > > > > > > > > > > > > in future, if we enable vfio-pci vendor ops, (i.e. a non-mdev device > > > > > > > > > is binding to vfio-pci, but is able to register migration region and do > > > > > > > > > migration transactions from a vendor provided affiliate driver), > > > > > > > > > the vendor driver would export (2) directly, under device node. > > > > > > > > > It is not able to provide (1) as there're no mdev devices involved. > > > > > > > > > > > > > > > > Ok, creating an alternate attribute for non-mdev devices makes sense. > > > > > > > > However, wouldn't that rather be a case (3)? The change here only > > > > > > > > refers to mdev devices. > > > > > > > > > > > > > > > as you pointed below, (3) and (2) serve the same purpose. > > > > > > > and I think a possible usage is to migrate between a non-mdev device and > > > > > > > an mdev device. so I think it's better for them both to use (2) rather > > > > > > > than creating (3). > > > > > > > > > > > > An mdev type is meant to define a software compatible interface, so in > > > > > > the case of mdev->mdev migration, doesn't migrating to a different type > > > > > > fail the most basic of compatibility tests that we expect userspace to > > > > > > perform? IOW, if two mdev types are migration compatible, it seems a > > > > > > prerequisite to that is that they provide the same software interface, > > > > > > which means they should be the same mdev type. > > > > > > > > > > > > In the hybrid cases of mdev->phys or phys->mdev, how does a > > > > > management > > > > > > tool begin to even guess what might be compatible? Are we expecting > > > > > > libvirt to probe ever device with this attribute in the system? Is > > > > > > there going to be a new class hierarchy created to enumerate all > > > > > > possible migrate-able devices? > > > > > > > > > > > yes, management tool needs to guess and test migration compatible > > > > > between two devices. But I think it's not the problem only for > > > > > mdev->phys or phys->mdev. even for mdev->mdev, management tool needs > > > > > to > > > > > first assume that the two mdevs have the same type of parent devices > > > > > (e.g.their pciids are equal). otherwise, it's still enumerating > > > > > possibilities. > > > > > > > > > > on the other hand, for two mdevs, > > > > > mdev1 from pdev1, its mdev_type is 1/2 of pdev1; > > > > > mdev2 from pdev2, its mdev_type is 1/4 of pdev2; > > > > > if pdev2 is exactly 2 times of pdev1, why not allow migration between > > > > > mdev1 <-> mdev2. > > > > > > > > How could the manage tool figure out that 1/2 of pdev1 is equivalent > > > > to 1/4 of pdev2? If we really want to allow such thing happen, the best > > > > choice is to report the same mdev type on both pdev1 and pdev2. > > > I think that's exactly the value of this migration_version interface. > > > the management tool can take advantage of this interface to know if two > > > devices are migration compatible, no matter they are mdevs, non-mdevs, > > > or mix. > > > > > > as I know, (please correct me if not right), current libvirt still > > > requires manually generating mdev devices, and it just duplicates src vm > > > configuration to the target vm. > > > for libvirt, currently it's always phys->phys and mdev->mdev (and of the > > > same mdev type). > > > But it does not justify that hybrid cases should not be allowed. otherwise, > > > why do we need to introduce this migration_version interface and leave > > > the judgement of migration compatibility to vendor driver? why not simply > > > set the criteria to something like "pciids of parent devices are equal, > > > and mdev types are equal" ? > > > > > > > > > > btw mdev<->phys just brings trouble to upper stack as Alex pointed out. > > > could you help me understand why it will bring trouble to upper stack? > > > > > > I think it just needs to read src migration_version under src dev node, > > > and test it in target migration version under target dev node. > > > > > > after all, through this interface we just help the upper layer > > > knowing available options through reading and testing, and they decide > > > to use it or not. > > > > > > > Can we simplify the requirement by allowing only mdev<->mdev and > > > > phys<->phys migration? If an customer does want to migrate between a > > > > mdev and phys, he could wrap physical device into a wrapped mdev > > > > instance (with the same type as the source mdev) instead of using vendor > > > > ops. Doing so does add some burden but if mdev<->phys is not dominant > > > > usage then such tradeoff might be worthywhile... > > > > > > > If the interfaces for phys<->phys and mdev<->mdev are consistent, it makes no > > > difference to phys<->mdev, right? > > > I think the vendor string for a mdev device is something like: > > > "Parent PCIID + mdev type + software version", and > > > that for a phys device is something like: > > > "PCIID + software version". > > > as long as we don't migrate between devices from different vendors, it's > > > easy for vendor driver to tell if a phys device is migration compatible > > > to a mdev device according it supports it or not. > > > > It surprises me that the PCIID matching is a requirement; I'd assumed > > with this clever mdev name setup that you could migrate between two > > different models in a series, or to a newer model, as long as they > > both supported the same mdev view. > > > hi Dave > the migration_version string is transparent to userspace, and is > completely defined by vendor driver. > I put it there just as an example of how vendor driver may implement it. > e.g. > the src migration_version string is "src PCIID + src software version", > then when this string is write to target migration_version node, > the vendor driver in the target device will compare it with its own > device info and software version. > If different models are allowed, the write just succeeds even > PCIIDs in src and target are different. > > so, it is the vendor driver to define whether two devices are able to > migrate, no matter their PCIIDs, mdev types, software versions..., which > provides vendor driver full flexibility. > > do you think it's good? Yeh that's OK; I guess it's going to need to have a big table in their with all the PCIIDs in. The alternative would be to abstract it a little; e.g. to say it's an Intel-gpu-core-v4 and then it would be less worried about the exact clock speed etc - but yes you might be right htat PCIIDs might be best for checking for quirks. Dave > Thanks > Yan > > > > > > > > > Thanks > > > Yan > > > > > > > > > > > > > > > > > > > > I agree that there was a gap in the previous proposal for non-mdev > > > > > > devices, but I think this bring a lot of questions that we need to > > > > > > puzzle through and libvirt will need to re-evaluate how they might > > > > > > decide to pick a migration target device. For example, I'm sure > > > > > > libvirt would reject any policy decisions regarding picking a physical > > > > > > device versus an mdev device. Had we previously left it that only a > > > > > > layer above libvirt would select a target device and libvirt only tests > > > > > > compatibility to that target device? > > > > > I'm not sure if there's a layer above libvirt would select a target > > > > > device. but if there is such a layer (even it's human), we need to > > > > > provide an interface for them to know whether their decision is suitable > > > > > for migration. The migration_version interface provides a potential to > > > > > allow mdev->phys migration, even libvirt may currently reject it. > > > > > > > > > > > > > > > > We also need to consider that this expands the namespace. If we no > > > > > > longer require matching types as the first level of comparison, then > > > > > > vendor migration strings can theoretically collide. How do we > > > > > > coordinate that can't happen? Thanks, > > > > > yes, it's indeed a problem. > > > > > could only allowing migration beteen devices from the same vendor be a > > > > > good > > > > > prerequisite? > > > > > > > > > > Thanks > > > > > Yan > > > > > > > > > > > > > > > > Is existence (and compatibility) of (1) a pre-req for possible > > > > > > > > > > existence (and compatibility) of (2)? > > > > > > > > > > > > > > > > > > > no. (2) does not reply on (1). > > > > > > > > > > > > > > > > Hm. Non-existence of (1) seems to imply "this type does not support > > > > > > > > migration". If an mdev created for such a type suddenly does support > > > > > > > > migration, it feels a bit odd. > > > > > > > > > > > > > > > yes. but I think if the condition happens, it should be reported a bug > > > > > > > to vendor driver. > > > > > > > should I add a line in the doc like "vendor driver should ensure that the > > > > > > > migration compatibility from migration_version under mdev_type should > > > > > be > > > > > > > consistent with that from migration_version under device node" ? > > > > > > > > > > > > > > > (It obviously cannot be a prereq for what I called (3) above.) > > > > > > > > > > > > > > > > > > > > > > > > > > > Does userspace need to check (1) or can it completely rely on (2), if > > > > > > > > > > it so chooses? > > > > > > > > > > > > > > > > > > > I think it can completely reply on (2) if compatibility check before > > > > > > > > > mdev creation is not required. > > > > > > > > > > > > > > > > > > > If devices with a different mdev type are indeed compatible, it > > > > > seems > > > > > > > > > > userspace can only find out after the devices have actually been > > > > > > > > > > created, as (1) does not apply? > > > > > > > > > yes, I think so. > > > > > > > > > > > > > > > > How useful would it be for userspace to even look at (1) in that case? > > > > > > > > It only knows if things have a chance of working if it actually goes > > > > > > > > ahead and creates devices. > > > > > > > > > > > > > > > hmm, is it useful for userspace to test the migration_version under mdev > > > > > > > type before it knows what mdev device to generate ? > > > > > > > like when the userspace wants to migrate an mdev device in src vm, > > > > > > > but it has not created target vm and the target mdev device. > > > > > > > > > > > > > > > > > > > > > > > > > > One of my worries is that the existence of an attribute with the > > > > > same > > > > > > > > > > name in two similar locations might lead to confusion. But maybe it > > > > > > > > > > isn't a problem. > > > > > > > > > > > > > > > > > > > Yes, I have the same feeling. but as (2) is for sysfs interface > > > > > > > > > consistency, to make it transparent to userspace tools like libvirt, > > > > > > > > > I guess the same name is necessary? > > > > > > > > > > > > > > > > What do we actually need here, I wonder? (1) and (2) seem to serve > > > > > > > > slightly different purposes, while (2) and what I called (3) have the > > > > > > > > same purpose. Is it important to userspace that (1) and (2) have the > > > > > > > > same name? > > > > > > > so change (1) to migration_type_version and (2) to > > > > > > > migration_instance_version? > > > > > > > But as they are under different locations, could that location imply > > > > > > > enough information? > > > > > > > > > > > > > > > > > > > > > Thanks > > > > > > > Yan > > > > > > > > > > > > > > > > > > > > > > > > > _______________________________________________ > > > > > intel-gvt-dev mailing list > > > > > intel-gvt-dev@lists.freedesktop.org > > > > > https://lists.freedesktop.org/mailman/listinfo/intel-gvt-dev > > > > > -- > > Dr. David Alan Gilbert / dgilbert@redhat.com / Manchester, UK > > > -- Dr. David Alan Gilbert / dgilbert@redhat.com / Manchester, UK