Received: by 2002:a25:683:0:0:0:0:0 with SMTP id 125csp177116ybg; Tue, 2 Jun 2020 20:32:07 -0700 (PDT) X-Google-Smtp-Source: ABdhPJy51cxtFZbZa2+5rZtVH0y6PvZJ+xyRZ4TFwN98115b2ovdsUEspRaM+TCWts9RHwFc0j/D X-Received: by 2002:a17:906:600a:: with SMTP id o10mr27300275ejj.544.1591155127460; Tue, 02 Jun 2020 20:32:07 -0700 (PDT) ARC-Seal: i=1; a=rsa-sha256; t=1591155127; cv=none; d=google.com; s=arc-20160816; b=zebwBh2k9/r7EfusyisZ8fesJRJR868QuQxgv5Bp9aW9oPZ+Hbc1fZ/i2Z7J2jAEJS 5ybgmUjR/pj3g/pcbbGKdLepkyjLv7Zc7bfI8YSn0hw/Igo5t6OOAdVWEPCr9eMOUhFD FOvrzflZJFirgID9qxIfwDc0lVKaf9XS8lOT4pH4fjROFMVPcwO/9Hi6gzP9rs/UYHXG n879bEcM29E3/Stx6sVOyBPoydHqvpUQShM9AX9fqQFVEo+WnmCLgTuSx4AGAOsO3CYq 9axAp1WrQu53J/zvmMBA/5P9KoUDxAYQxA/UWtNKzPidXcNTHDzvzNFrwGCR1LGtonyR jyIA== ARC-Message-Signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=google.com; s=arc-20160816; h=list-id:precedence:sender:user-agent:in-reply-to :content-disposition:mime-version:references:reply-to:message-id :subject:cc:to:from:date:ironport-sdr:ironport-sdr; bh=IvtGc2ZgeLGUFfPbkgR33AUtSAuMp61uQoM2EgviaWE=; b=UiizAmcYW56eD8gr3RimKQt+hAmFBZcZf5h/ZmjEQDbRoK4IuJYph4/hRlPFpIzkkj 2whUXnT6S5zZAgcOBLIGY4brxgQJp3pvGksgJ1lWmkZzXnZBR+k0MwnfSWCqvATU3pF+ Y3GjWFylJMxbTHfOF7tk9YXgeVr8/gdHQxhXr2tdWYbc+9Ae+p/8QNSMXfVe3OQx0Oa/ izmQEYBokKm3F2aVUq+IDuRUZggcibWahUDrN0K7uxv6cW4ZlWkfKXKcdnLKk5fBS0QV Z67HrpOHIsYuKMowyhenEVmEQ1oeL4PqiAx0dh6KD1Z2BNz2zAuMfBIujpa87eO1rE1L 4aTw== ARC-Authentication-Results: i=1; mx.google.com; spf=pass (google.com: domain of linux-kernel-owner@vger.kernel.org designates 23.128.96.18 as permitted sender) smtp.mailfrom=linux-kernel-owner@vger.kernel.org; dmarc=fail (p=NONE sp=NONE dis=NONE) header.from=intel.com Return-Path: Received: from vger.kernel.org (vger.kernel.org. [23.128.96.18]) by mx.google.com with ESMTP id k19si356165edj.180.2020.06.02.20.31.41; Tue, 02 Jun 2020 20:32:07 -0700 (PDT) Received-SPF: pass (google.com: domain of linux-kernel-owner@vger.kernel.org designates 23.128.96.18 as permitted sender) client-ip=23.128.96.18; Authentication-Results: mx.google.com; spf=pass (google.com: domain of linux-kernel-owner@vger.kernel.org designates 23.128.96.18 as permitted sender) smtp.mailfrom=linux-kernel-owner@vger.kernel.org; dmarc=fail (p=NONE sp=NONE dis=NONE) header.from=intel.com Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1725924AbgFCD3w (ORCPT + 99 others); Tue, 2 Jun 2020 23:29:52 -0400 Received: from mga14.intel.com ([192.55.52.115]:3533 "EHLO mga14.intel.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1725780AbgFCD3v (ORCPT ); Tue, 2 Jun 2020 23:29:51 -0400 IronPort-SDR: uxpAS0DcYtzkq0jYUMZ2e4Qmc0HWevv4buipPrBaGqeXqliMIUnZNze483+pG9SdboJSTOQwtr leF1biiIa0UA== X-Amp-Result: SKIPPED(no attachment in message) X-Amp-File-Uploaded: False Received: from fmsmga001.fm.intel.com ([10.253.24.23]) by fmsmga103.fm.intel.com with ESMTP/TLS/ECDHE-RSA-AES256-GCM-SHA384; 02 Jun 2020 20:29:51 -0700 IronPort-SDR: JqQz0cMzsxK+mrTR1bp5QJcieiHl2ZE5cJONeUSiVAREu0ZiMrxhulgC/XtD+AoOdmyXQ1nWC5 wX4j6aBbdKew== X-ExtLoop1: 1 X-IronPort-AV: E=Sophos;i="5.73,467,1583222400"; d="scan'208";a="377964526" Received: from joy-optiplex-7040.sh.intel.com (HELO joy-OptiPlex-7040) ([10.239.13.16]) by fmsmga001.fm.intel.com with ESMTP; 02 Jun 2020 20:29:44 -0700 Date: Tue, 2 Jun 2020 23:19:48 -0400 From: Yan Zhao To: Alex Williamson Cc: "Dr. David Alan Gilbert" , "Tian, Kevin" , "cjia@nvidia.com" , "kvm@vger.kernel.org" , "linux-doc@vger.kernel.org" , "libvir-list@redhat.com" , "Zhengxiao.zx@alibaba-inc.com" , "shuangtai.tst@alibaba-inc.com" , "qemu-devel@nongnu.org" , "kwankhede@nvidia.com" , "eauger@redhat.com" , "corbet@lwn.net" , "Liu, Yi L" , "eskultet@redhat.com" , "Yang, Ziye" , "mlevitsk@redhat.com" , "pasic@linux.ibm.com" , "aik@ozlabs.ru" , "felipe@nutanix.com" , "Ken.Xue@amd.com" , "Zeng, Xin" , "zhenyuw@linux.intel.com" , "dinechin@redhat.com" , "intel-gvt-dev@lists.freedesktop.org" , "Liu, Changpeng" , "berrange@redhat.com" , Cornelia Huck , "linux-kernel@vger.kernel.org" , "Wang, Zhi A" , "jonathan.davies@nutanix.com" , "He, Shaopeng" Subject: Re: [PATCH v5 0/4] introduction of migration_version attribute for VFIO live migration Message-ID: <20200603031948.GB12300@joy-OptiPlex-7040> Reply-To: Yan Zhao References: <20200426013628.GC12879@joy-OptiPlex-7040> <20200427153743.GK2923@work-vm> <20200428005429.GJ12879@joy-OptiPlex-7040> <20200428141437.GG2794@work-vm> <20200429072616.GL12879@joy-OptiPlex-7040> <20200429082201.GA2834@work-vm> <20200429093555.GM12879@joy-OptiPlex-7040> <20200429094844.GE2834@work-vm> <20200430003949.GN12879@joy-OptiPlex-7040> <20200602165527.34137955@x1.home> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Disposition: inline In-Reply-To: <20200602165527.34137955@x1.home> User-Agent: Mutt/1.9.4 (2018-02-28) Sender: linux-kernel-owner@vger.kernel.org Precedence: bulk List-ID: X-Mailing-List: linux-kernel@vger.kernel.org On Tue, Jun 02, 2020 at 04:55:27PM -0600, Alex Williamson wrote: > On Wed, 29 Apr 2020 20:39:50 -0400 > Yan Zhao wrote: > > > On Wed, Apr 29, 2020 at 05:48:44PM +0800, Dr. David Alan Gilbert wrote: > > > > > > > > > > > > > > > > > An mdev type is meant to define a software compatible interface, so in > > > > > > > > > > > > > > > the case of mdev->mdev migration, doesn't migrating to a different type > > > > > > > > > > > > > > > fail the most basic of compatibility tests that we expect userspace to > > > > > > > > > > > > > > > perform? IOW, if two mdev types are migration compatible, it seems a > > > > > > > > > > > > > > > prerequisite to that is that they provide the same software interface, > > > > > > > > > > > > > > > which means they should be the same mdev type. > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > In the hybrid cases of mdev->phys or phys->mdev, how does a > > > > > > > > > > > > > > management > > > > > > > > > > > > > > > tool begin to even guess what might be compatible? Are we expecting > > > > > > > > > > > > > > > libvirt to probe ever device with this attribute in the system? Is > > > > > > > > > > > > > > > there going to be a new class hierarchy created to enumerate all > > > > > > > > > > > > > > > possible migrate-able devices? > > > > > > > > > > > > > > > > > > > > > > > > > > > > > yes, management tool needs to guess and test migration compatible > > > > > > > > > > > > > > between two devices. But I think it's not the problem only for > > > > > > > > > > > > > > mdev->phys or phys->mdev. even for mdev->mdev, management tool needs > > > > > > > > > > > > > > to > > > > > > > > > > > > > > first assume that the two mdevs have the same type of parent devices > > > > > > > > > > > > > > (e.g.their pciids are equal). otherwise, it's still enumerating > > > > > > > > > > > > > > possibilities. > > > > > > > > > > > > > > > > > > > > > > > > > > > > on the other hand, for two mdevs, > > > > > > > > > > > > > > mdev1 from pdev1, its mdev_type is 1/2 of pdev1; > > > > > > > > > > > > > > mdev2 from pdev2, its mdev_type is 1/4 of pdev2; > > > > > > > > > > > > > > if pdev2 is exactly 2 times of pdev1, why not allow migration between > > > > > > > > > > > > > > mdev1 <-> mdev2. > > > > > > > > > > > > > > > > > > > > > > > > > > How could the manage tool figure out that 1/2 of pdev1 is equivalent > > > > > > > > > > > > > to 1/4 of pdev2? If we really want to allow such thing happen, the best > > > > > > > > > > > > > choice is to report the same mdev type on both pdev1 and pdev2. > > > > > > > > > > > > I think that's exactly the value of this migration_version interface. > > > > > > > > > > > > the management tool can take advantage of this interface to know if two > > > > > > > > > > > > devices are migration compatible, no matter they are mdevs, non-mdevs, > > > > > > > > > > > > or mix. > > > > > > > > > > > > > > > > > > > > > > > > as I know, (please correct me if not right), current libvirt still > > > > > > > > > > > > requires manually generating mdev devices, and it just duplicates src vm > > > > > > > > > > > > configuration to the target vm. > > > > > > > > > > > > for libvirt, currently it's always phys->phys and mdev->mdev (and of the > > > > > > > > > > > > same mdev type). > > > > > > > > > > > > But it does not justify that hybrid cases should not be allowed. otherwise, > > > > > > > > > > > > why do we need to introduce this migration_version interface and leave > > > > > > > > > > > > the judgement of migration compatibility to vendor driver? why not simply > > > > > > > > > > > > set the criteria to something like "pciids of parent devices are equal, > > > > > > > > > > > > and mdev types are equal" ? > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > btw mdev<->phys just brings trouble to upper stack as Alex pointed out. > > > > > > > > > > > > could you help me understand why it will bring trouble to upper stack? > > > > > > > > > > > > > > > > > > > > > > > > I think it just needs to read src migration_version under src dev node, > > > > > > > > > > > > and test it in target migration version under target dev node. > > > > > > > > > > > > > > > > > > > > > > > > after all, through this interface we just help the upper layer > > > > > > > > > > > > knowing available options through reading and testing, and they decide > > > > > > > > > > > > to use it or not. > > > > > > > > > > > > > > > > > > > > > > > > > Can we simplify the requirement by allowing only mdev<->mdev and > > > > > > > > > > > > > phys<->phys migration? If an customer does want to migrate between a > > > > > > > > > > > > > mdev and phys, he could wrap physical device into a wrapped mdev > > > > > > > > > > > > > instance (with the same type as the source mdev) instead of using vendor > > > > > > > > > > > > > ops. Doing so does add some burden but if mdev<->phys is not dominant > > > > > > > > > > > > > usage then such tradeoff might be worthywhile... > > > > > > > > > > > > > > > > > > > > > > > > > If the interfaces for phys<->phys and mdev<->mdev are consistent, it makes no > > > > > > > > > > > > difference to phys<->mdev, right? > > > > > > > > > > > > I think the vendor string for a mdev device is something like: > > > > > > > > > > > > "Parent PCIID + mdev type + software version", and > > > > > > > > > > > > that for a phys device is something like: > > > > > > > > > > > > "PCIID + software version". > > > > > > > > > > > > as long as we don't migrate between devices from different vendors, it's > > > > > > > > > > > > easy for vendor driver to tell if a phys device is migration compatible > > > > > > > > > > > > to a mdev device according it supports it or not. > > > > > > > > > > > > > > > > > > > > > > It surprises me that the PCIID matching is a requirement; I'd assumed > > > > > > > > > > > with this clever mdev name setup that you could migrate between two > > > > > > > > > > > different models in a series, or to a newer model, as long as they > > > > > > > > > > > both supported the same mdev view. > > > > > > > > > > > > > > > > > > > > > hi Dave > > > > > > > > > > the migration_version string is transparent to userspace, and is > > > > > > > > > > completely defined by vendor driver. > > > > > > > > > > I put it there just as an example of how vendor driver may implement it. > > > > > > > > > > e.g. > > > > > > > > > > the src migration_version string is "src PCIID + src software version", > > > > > > > > > > then when this string is write to target migration_version node, > > > > > > > > > > the vendor driver in the target device will compare it with its own > > > > > > > > > > device info and software version. > > > > > > > > > > If different models are allowed, the write just succeeds even > > > > > > > > > > PCIIDs in src and target are different. > > > > > > > > > > > > > > > > > > > > so, it is the vendor driver to define whether two devices are able to > > > > > > > > > > migrate, no matter their PCIIDs, mdev types, software versions..., which > > > > > > > > > > provides vendor driver full flexibility. > > > > > > > > > > > > > > > > > > > > do you think it's good? > > > > > > > > > > > > > > > > > > Yeh that's OK; I guess it's going to need to have a big table in their > > > > > > > > > with all the PCIIDs in. > > > > > > > > > The alternative would be to abstract it a little; e.g. to say it's > > > > > > > > > an Intel-gpu-core-v4 and then it would be less worried about the exact > > > > > > > > > clock speed etc - but yes you might be right htat PCIIDs might be best > > > > > > > > > for checking for quirks. > > > > > > > > > > > > > > > > > glad that you are agreed with it:) > > > > > > > > I think the vendor driver still can choose a way to abstract a little > > > > > > > > (e.g. Intel-gpu-core-v4...) if they think it's better. In that case, the > > > > > > > > migration_string would be something like "Intel-gpu-core-v4 + instance > > > > > > > > number + software version". > > > > > > > > IOW, they can choose anything they think appropriate to identify migration > > > > > > > > compatibility of a device. > > > > > > > > But Alex is right, we have to prevent namespace overlapping. So I think > > > > > > > > we need to ensure src and target devices are from the same vendors. > > > > > > > > or, any other ideas? > > > > > > > > > > > > > > That's why I kept the 'Intel' in that example; or PCI vendor ID; I was > > > > > > Yes, it's a good idea! > > > > > > could we add a line in the doc saying that > > > > > > it is the vendor driver to add a unique string to avoid namespace > > > > > > collision? > > > > > > > > > > So why don't we split the difference; lets say that it should start with > > > > > the hex PCI Vendor ID. > > > > > > > > > The problem is for mdev devices, if the parent devices are not PCI devices, > > > > they don't have PCI vendor IDs. > > > > > > Hmm it would be best not to invent a whole new way of giving unique > > > idenitifiers for vendors if we can. > > > > > what about leveraging the flags in vfio device info ? > > > > #define VFIO_DEVICE_FLAGS_RESET (1 << 0) /* Device supports reset */ > > #define VFIO_DEVICE_FLAGS_PCI (1 << 1) /* vfio-pci device */ > > #define VFIO_DEVICE_FLAGS_PLATFORM (1 << 2) /* vfio-platform device */ > > #define VFIO_DEVICE_FLAGS_AMBA (1 << 3) /* vfio-amba device */ > > #define VFIO_DEVICE_FLAGS_CCW (1 << 4) /* vfio-ccw device */ > > #define VFIO_DEVICE_FLAGS_AP (1 << 5) /* vfio-ap device */ > > > > Then for migration_version string, > > The first 64 bits are for device type, the second 64 bits are for device id. > > e.g. > > for PCI devices, it could be > > VFIO_DEVICE_FLAGS_PCI + PCI ID. > > > > Currently in the doc, we only define PCI devices to use PCI ID as the second > > 64 bits. In future, if other types of devices want to support migration, > > they can define their own parts of device id. e.g. use ACPI ID as the > > second 64-bit... > > > > sounds good? > > [dead thread resurrection alert] > > Not really. We're deep into territory that we were trying to avoid. > We had previously defined the version string as opaque (not > transparent) specifically because we did not want userspace to make > assumptions about compatibility based on the content of the string. It > was 100% left to the vendor driver to determine compatibility. The > mdev type was the full extent of the first level filter that userspace > could use to narrow the set of potentially compatible devices. If we > remove that due to physical device migration support, I'm not sure how > we simplify the problem for userspace. > > We need to step away from PCI IDs and parent devices. We're not > designing a solution that only works for PCI, there's no guarantee that > parent devices are similar or even from the same vendor. > > Does the mdev type sufficiently solve the problem for mdev devices? If > so, then what can we learn from it and how can we apply an equivalence > to physical devices? For example, should a vfio bus driver (vfio-pci > or vfio-mdev) expose vfio_migration_type and vfio_migration_version > attributes under the device in sysfs where the _type provides the first > level, user transparent, matching string (ex. mdev type for mdev > devices) while the _version provides the user opaque, vendor known > compatibility test? > > This pushes the problem out to the drivers where we can perhaps > incorporate the module name to avoid collisions. For example Yan's > vendor extension proposal makes use of vfio-pci with extension modules > loaded via an alias incorporating the PCI vendor and device ID. So > vfio-pci might use a type of "vfio-pci:$ALIAS". > > It's still a bit messy that someone needs to go evaluate all these > types between devices that exist and mdev devices that might exist if > created, but I don't have any good ideas to resolve that (maybe a new > class hierarchy?). Thanks, hi Alex yes, with the same mdev_type, user still has to enumerate all parent devices and test between the supported mdev_types to know whether two mdev devices are compatible. maybe this is not a problem? in reality, it is the administrator that specifies two devices and the management tool feedbacks compatibility result. management tool is not required to pre-test and setup the compatibility map beforehand. If so, then the only problem left is namespace collision. given that the migration_version nodes is exported by vendor driver, maybe it can also embed its module name in the migration version string, like "i915" in "i915-GVTg_V5_8", as you suggested above. with module name as the first mandatory field in version string and skipping the enumeration/testing problem, we can happyly unify migration across mdev and phys devices. e.g. it is possible to migrate between VFs in sriov and mdevs in siov to achieve backwards compatibility. Thanks Yan >