Return-Path: Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1752799AbZKIRvM (ORCPT ); Mon, 9 Nov 2009 12:51:12 -0500 Received: (majordomo@vger.kernel.org) by vger.kernel.org id S1752692AbZKIRvL (ORCPT ); Mon, 9 Nov 2009 12:51:11 -0500 Received: from smtprelay02.ispgateway.de ([80.67.18.14]:58339 "EHLO smtprelay02.ispgateway.de" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1751894AbZKIRvL convert rfc822-to-8bit (ORCPT ); Mon, 9 Nov 2009 12:51:11 -0500 Date: Mon, 9 Nov 2009 18:51:05 +0100 From: Peter Feuerer To: Andrew Morton Cc: linux-kernel@vger.kernel.org, Borislav Petkov , lenb@kernel.org, Andreas Mohr , Peter Feuerer Subject: [PATCH 1/2] acerhdf: Return temperature in milidegree instead of degree Message-Id: <20091109185105.6028c057.peter@piie.net> X-Mailer: Sylpheed 2.7.1 (GTK+ 2.18.3; i686-pc-linux-gnu) Mime-Version: 1.0 Content-Type: text/plain; charset=ISO-8859-1 Content-Transfer-Encoding: 8BIT X-Df-Sender: 650477 Sender: linux-kernel-owner@vger.kernel.org List-ID: X-Mailing-List: linux-kernel@vger.kernel.org Content-Length: 2110 Lines: 77 Hi Andrew, please apply. thanks and regards, --peter -- Return temperature in milidegree instead of degree, as sysfs-api requires the temperature in milidegree. Signed-off-by: Peter Feuerer Tested-by: Borislav Petkov Cc: Andreas Mohr Cc: Len Brown --- drivers/platform/x86/acerhdf.c | 12 ++++++------ 1 files changed, 6 insertions(+), 6 deletions(-) diff --git a/drivers/platform/x86/acerhdf.c b/drivers/platform/x86/acerhdf.c index 0a8f735..ab64522 100644 --- a/drivers/platform/x86/acerhdf.c +++ b/drivers/platform/x86/acerhdf.c @@ -52,7 +52,7 @@ */ #undef START_IN_KERNEL_MODE -#define DRV_VER "0.5.17" +#define DRV_VER "0.5.18" /* * According to the Atom N270 datasheet, @@ -61,7 +61,7 @@ * measured by the on-die thermal monitor are within 0 <= Tj <= 90. So, * assume 89?C is critical temperature. */ -#define ACERHDF_TEMP_CRIT 89 +#define ACERHDF_TEMP_CRIT 89000 #define ACERHDF_FAN_OFF 0 #define ACERHDF_FAN_AUTO 1 @@ -69,7 +69,7 @@ * No matter what value the user puts into the fanon variable, turn on the fan * at 80 degree Celsius to prevent hardware damage */ -#define ACERHDF_MAX_FANON 80 +#define ACERHDF_MAX_FANON 80000 /* * Maximum interval between two temperature checks is 15 seconds, as the die @@ -85,8 +85,8 @@ static int kernelmode; #endif static unsigned int interval = 10; -static unsigned int fanon = 63; -static unsigned int fanoff = 58; +static unsigned int fanon = 63000; +static unsigned int fanoff = 58000; static unsigned int verbose; static unsigned int fanstate = ACERHDF_FAN_AUTO; static char force_bios[16]; @@ -171,7 +171,7 @@ static int acerhdf_get_temp(int *temp) if (ec_read(bios_cfg->tempreg, &read_temp)) return -EINVAL; - *temp = read_temp; + *temp = read_temp * 1000; return 0; } -- 1.6.5.2 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/