Return-Path: Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1752933Ab2JIGDI (ORCPT ); Tue, 9 Oct 2012 02:03:08 -0400 Received: from mail-qc0-f174.google.com ([209.85.216.174]:38957 "EHLO mail-qc0-f174.google.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1752756Ab2JIGC7 (ORCPT ); Tue, 9 Oct 2012 02:02:59 -0400 From: Len Brown To: linux-acpi@vger.kernel.org, linux-pm@vger.kernel.org Cc: linux-kernel@vger.kernel.org, Zhang Rui Subject: [PATCH 11/30] Thermal: Introduce simple arbitrator for setting device cooling state Date: Tue, 9 Oct 2012 01:54:01 -0400 Message-Id: X-Mailer: git-send-email 1.8.0.rc1 In-Reply-To: <1349762060-25334-1-git-send-email-lenb@kernel.org> References: <1349762060-25334-1-git-send-email-lenb@kernel.org> In-Reply-To: References: Reply-To: Len Brown Organization: Intel Open Source Technology Center Sender: linux-kernel-owner@vger.kernel.org List-ID: X-Mailing-List: linux-kernel@vger.kernel.org Content-Length: 5032 Lines: 148 From: Zhang Rui This fixes the problem that a cooling device may be referenced by by multiple trip points in multiple thermal zones. With this patch, we have two stages for updating a thermal zone, 1. check if a thermal_instance needs to be updated or not 2. update the cooling device, based on the target cooling state of all its instances. Note that, currently, the cooling device is set to the deepest cooling state required. Signed-off-by: Zhang Rui Reviewed-by: Rafael J. Wysocki Reviewed-by: Eduardo Valentin --- drivers/thermal/thermal_sys.c | 44 ++++++++++++++++++++++++++++++++++++++++--- include/linux/thermal.h | 1 + 2 files changed, 42 insertions(+), 3 deletions(-) diff --git a/drivers/thermal/thermal_sys.c b/drivers/thermal/thermal_sys.c index 70045c1..36ae2f4 100644 --- a/drivers/thermal/thermal_sys.c +++ b/drivers/thermal/thermal_sys.c @@ -41,6 +41,7 @@ MODULE_AUTHOR("Zhang Rui"); MODULE_DESCRIPTION("Generic thermal management sysfs support"); MODULE_LICENSE("GPL"); +#define THERMAL_NO_TARGET -1UL /* * This structure is used to describe the behavior of * a certain cooling device on a certain trip point @@ -54,6 +55,7 @@ struct thermal_instance { int trip; unsigned long upper; /* Highest cooling state for this trip point */ unsigned long lower; /* Lowest cooling state for this trip point */ + unsigned long target; /* expected cooling state */ char attr_name[THERMAL_NAME_LENGTH]; struct device_attribute attr; struct list_head tz_node; /* node in tz->thermal_instances */ @@ -853,6 +855,7 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, dev->trip = trip; dev->upper = upper; dev->lower = lower; + dev->target = THERMAL_NO_TARGET; result = get_idr(&tz->idr, &tz->lock, &dev->id); if (result) @@ -990,6 +993,7 @@ thermal_cooling_device_register(char *type, void *devdata, strcpy(cdev->type, type); INIT_LIST_HEAD(&cdev->thermal_instances); cdev->ops = ops; + cdev->updated = true; cdev->device.class = &thermal_class; cdev->devdata = devdata; dev_set_name(&cdev->device, "cooling_device%d", cdev->id); @@ -1081,6 +1085,34 @@ void thermal_cooling_device_unregister(struct } EXPORT_SYMBOL(thermal_cooling_device_unregister); +static void thermal_cdev_do_update(struct thermal_cooling_device *cdev) +{ + struct thermal_instance *instance; + unsigned long target = 0; + + /* cooling device is updated*/ + if (cdev->updated) + return; + + /* Make sure cdev enters the deepest cooling state */ + list_for_each_entry(instance, &cdev->thermal_instances, cdev_node) { + if (instance->target == THERMAL_NO_TARGET) + continue; + if (instance->target > target) + target = instance->target; + } + cdev->ops->set_cur_state(cdev, target); + cdev->updated = true; +} + +static void thermal_zone_do_update(struct thermal_zone_device *tz) +{ + struct thermal_instance *instance; + + list_for_each_entry(instance, &tz->thermal_instances, tz_node) + thermal_cdev_do_update(instance->cdev); +} + /* * Cooling algorithm for active trip points * @@ -1138,19 +1170,24 @@ static void thermal_zone_trip_update(struct thermal_zone_device *tz, cur_state = cur_state > instance->lower ? (cur_state - 1) : instance->lower; } - cdev->ops->set_cur_state(cdev, cur_state); + instance->target = cur_state; + cdev->updated = false; /* cooling device needs update */ } } else { /* below trip */ list_for_each_entry(instance, &tz->thermal_instances, tz_node) { if (instance->trip != trip) continue; + /* Do not use the inactive thermal instance */ + if (instance->target == THERMAL_NO_TARGET) + continue; cdev = instance->cdev; cdev->ops->get_cur_state(cdev, &cur_state); cur_state = cur_state > instance->lower ? - (cur_state - 1) : instance->lower; - cdev->ops->set_cur_state(cdev, cur_state); + (cur_state - 1) : THERMAL_NO_TARGET; + instance->target = cur_state; + cdev->updated = false; /* cooling device needs update */ } } @@ -1211,6 +1248,7 @@ void thermal_zone_device_update(struct thermal_zone_device *tz) } } + thermal_zone_do_update(tz); if (tz->forced_passive) thermal_zone_device_passive(tz, temp, tz->forced_passive, THERMAL_TRIPS_NONE); diff --git a/include/linux/thermal.h b/include/linux/thermal.h index 9ae378a..de0515a 100644 --- a/include/linux/thermal.h +++ b/include/linux/thermal.h @@ -94,6 +94,7 @@ struct thermal_cooling_device { struct device device; void *devdata; const struct thermal_cooling_device_ops *ops; + bool updated; /* true if the cooling device does not need update */ struct list_head thermal_instances; struct list_head node; }; -- 1.8.0.rc1 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/