Add #cooling-cells for when the gpu acts as a cooling device.
Signed-off-by: Guido Günther <[email protected]>
---
.../devicetree/bindings/display/etnaviv/etnaviv-drm.txt | 1 +
1 file changed, 1 insertion(+)
diff --git a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
index 8def11b16a24..640592e8ab2e 100644
--- a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
+++ b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
@@ -21,6 +21,7 @@ Required properties:
Optional properties:
- power-domains: a power domain consumer specifier according to
Documentation/devicetree/bindings/power/power_domain.txt
+- #cooling-cells: : If used as a cooling device, must be <2>
example:
--
2.23.0.rc1
On Mi, 2019-09-11 at 19:40 -0700, Guido Günther wrote:
> Add #cooling-cells for when the gpu acts as a cooling device.
>
> Signed-off-by: Guido Günther <[email protected]>
Reviewed-by: Lucas Stach <[email protected]>
> ---
> .../devicetree/bindings/display/etnaviv/etnaviv-drm.txt | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> index 8def11b16a24..640592e8ab2e 100644
> --- a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> +++ b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> @@ -21,6 +21,7 @@ Required properties:
> Optional properties:
> - power-domains: a power domain consumer specifier according to
> Documentation/devicetree/bindings/power/power_domain.txt
> +- #cooling-cells: : If used as a cooling device, must be <2>
>
> example:
>
On Wed, 11 Sep 2019 19:40:36 -0700, =?UTF-8?q?Guido=20G=C3=BCnther?= wrote:
> Add #cooling-cells for when the gpu acts as a cooling device.
>
> Signed-off-by: Guido G?nther <[email protected]>
> ---
> .../devicetree/bindings/display/etnaviv/etnaviv-drm.txt | 1 +
> 1 file changed, 1 insertion(+)
>
Acked-by: Rob Herring <[email protected]>
On Mon, Sep 16, 2019 at 04:32:55PM +0200, Lucas Stach wrote:
> On Mi, 2019-09-11 at 19:40 -0700, Guido G?nther wrote:
> > Add #cooling-cells for when the gpu acts as a cooling device.
> >
> > Signed-off-by: Guido G?nther <[email protected]>
>
> Reviewed-by: Lucas Stach <[email protected]>
Lucas,
I assume you will pick it up.
Shawn
>
> > ---
> > .../devicetree/bindings/display/etnaviv/etnaviv-drm.txt | 1 +
> > 1 file changed, 1 insertion(+)
> >
> > diff --git a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> > index 8def11b16a24..640592e8ab2e 100644
> > --- a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> > +++ b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> > @@ -21,6 +21,7 @@ Required properties:
> > Optional properties:
> > - power-domains: a power domain consumer specifier according to
> > Documentation/devicetree/bindings/power/power_domain.txt
> > +- #cooling-cells: : If used as a cooling device, must be <2>
> >
> > example:
> >
>
Hi,
On Wed, Sep 11, 2019 at 07:40:36PM -0700, Guido G?nther wrote:
> Add #cooling-cells for when the gpu acts as a cooling device.
>
> Signed-off-by: Guido G?nther <[email protected]>
> ---
> .../devicetree/bindings/display/etnaviv/etnaviv-drm.txt | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> index 8def11b16a24..640592e8ab2e 100644
> --- a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> +++ b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> @@ -21,6 +21,7 @@ Required properties:
> Optional properties:
> - power-domains: a power domain consumer specifier according to
> Documentation/devicetree/bindings/power/power_domain.txt
> +- #cooling-cells: : If used as a cooling device, must be <2>
The other patch of the series made it into linux-next already but this
documentation fixup didn't. Anything i can do to get this applied as
well so documentation stays in sync?
Cheers,
-- Guido
>
> example:
>
> --
> 2.23.0.rc1
>
>
> _______________________________________________
> linux-arm-kernel mailing list
> [email protected]
> http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
On Fr, 2019-10-18 at 15:50 +0200, Guido Günther wrote:
> Hi,
> On Wed, Sep 11, 2019 at 07:40:36PM -0700, Guido Günther wrote:
> > Add #cooling-cells for when the gpu acts as a cooling device.
> >
> > Signed-off-by: Guido Günther <[email protected]>
> > ---
> > .../devicetree/bindings/display/etnaviv/etnaviv-drm.txt | 1 +
> > 1 file changed, 1 insertion(+)
> >
> > diff --git a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> > index 8def11b16a24..640592e8ab2e 100644
> > --- a/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> > +++ b/Documentation/devicetree/bindings/display/etnaviv/etnaviv-drm.txt
> > @@ -21,6 +21,7 @@ Required properties:
> > Optional properties:
> > - power-domains: a power domain consumer specifier according to
> > Documentation/devicetree/bindings/power/power_domain.txt
> > +- #cooling-cells: : If used as a cooling device, must be <2>
>
> The other patch of the series made it into linux-next already but this
> documentation fixup didn't. Anything i can do to get this applied as
> well so documentation stays in sync?
I've applied and pushed this to my etnaviv/next branch just now, so it
should show up in linux-next pretty soon.
Regards,
Lucas