2020-12-02 09:21:40

by Stanley Chu

[permalink] [raw]
Subject: [PATCH v3] scsi: ufs: Remove pre-defined initial voltage values of device powers

UFS specficication allows different VCC configurations for UFS devices,
for example,
(1). 2.70V - 3.60V (Activated by default in UFS core driver)
(2). 1.70V - 1.95V (Activated if "vcc-supply-1p8" is declared in
device tree)
(3). 2.40V - 2.70V (Supported since UFS 3.x)

With the introduction of UFS 3.x products, an issue is happening that
UFS driver will use wrong "min_uV-max_uV" values to configure the
voltage of VCC regulator on UFU 3.x products with the configuration (3)
used.

To solve this issue, we simply remove pre-defined initial VCC voltage
values in UFS core driver with below reasons,

1. UFS specifications do not define how to detect the VCC configuration
supported by attached device.

2. Device tree already supports standard regulator properties.

Therefore VCC voltage shall be defined correctly in device tree, and
shall not changed by UFS driver. What UFS driver needs to do is simply
enable or disable the VCC regulator only.

Similar change is applied to VCCQ and VCCQ2 as well.

Note that we keep struct ufs_vreg unchanged. This allows vendors to
configure proper min_uV and max_uV of any regulators to make
regulator_set_voltage() works during regulator toggling flow in the
future. Without specific vendor configurations, min_uV and max_uV will
be NULL by default and UFS core driver will enable or disable the
regulator only without adjusting its voltage.

Acked-by: Avri Altman <[email protected]>
Reviewed-by: Asutosh Das <[email protected]>
Reviewed-by: Bjorn Andersson <[email protected]>
Signed-off-by: Stanley Chu <[email protected]>
---
drivers/scsi/ufs/ufshcd-pltfrm.c | 19 -------------------
1 file changed, 19 deletions(-)

diff --git a/drivers/scsi/ufs/ufshcd-pltfrm.c b/drivers/scsi/ufs/ufshcd-pltfrm.c
index 0619cfbfbdbb..1a69949a4ea1 100644
--- a/drivers/scsi/ufs/ufshcd-pltfrm.c
+++ b/drivers/scsi/ufs/ufshcd-pltfrm.c
@@ -134,25 +134,6 @@ static int ufshcd_populate_vreg(struct device *dev, const char *name,
dev_info(dev, "%s: unable to find %s\n", __func__, prop_name);
vreg->max_uA = 0;
}
-
- if (!strcmp(name, "vcc")) {
- if (of_property_read_bool(np, "vcc-supply-1p8")) {
- vreg->min_uV = UFS_VREG_VCC_1P8_MIN_UV;
- vreg->max_uV = UFS_VREG_VCC_1P8_MAX_UV;
- } else {
- vreg->min_uV = UFS_VREG_VCC_MIN_UV;
- vreg->max_uV = UFS_VREG_VCC_MAX_UV;
- }
- } else if (!strcmp(name, "vccq")) {
- vreg->min_uV = UFS_VREG_VCCQ_MIN_UV;
- vreg->max_uV = UFS_VREG_VCCQ_MAX_UV;
- } else if (!strcmp(name, "vccq2")) {
- vreg->min_uV = UFS_VREG_VCCQ2_MIN_UV;
- vreg->max_uV = UFS_VREG_VCCQ2_MAX_UV;
- }
-
- goto out;
-
out:
if (!ret)
*out_vreg = vreg;
--
2.18.0


2020-12-02 10:20:56

by Can Guo

[permalink] [raw]
Subject: Re: [PATCH v3] scsi: ufs: Remove pre-defined initial voltage values of device powers

On 2020-12-02 17:18, Stanley Chu wrote:
> UFS specficication allows different VCC configurations for UFS devices,
> for example,
> (1). 2.70V - 3.60V (Activated by default in UFS core driver)
> (2). 1.70V - 1.95V (Activated if "vcc-supply-1p8" is declared in
> device tree)
> (3). 2.40V - 2.70V (Supported since UFS 3.x)
>
> With the introduction of UFS 3.x products, an issue is happening that
> UFS driver will use wrong "min_uV-max_uV" values to configure the
> voltage of VCC regulator on UFU 3.x products with the configuration (3)
> used.
>
> To solve this issue, we simply remove pre-defined initial VCC voltage
> values in UFS core driver with below reasons,
>
> 1. UFS specifications do not define how to detect the VCC configuration
> supported by attached device.
>
> 2. Device tree already supports standard regulator properties.
>
> Therefore VCC voltage shall be defined correctly in device tree, and
> shall not changed by UFS driver. What UFS driver needs to do is simply
> enable or disable the VCC regulator only.
>
> Similar change is applied to VCCQ and VCCQ2 as well.
>
> Note that we keep struct ufs_vreg unchanged. This allows vendors to
> configure proper min_uV and max_uV of any regulators to make
> regulator_set_voltage() works during regulator toggling flow in the
> future. Without specific vendor configurations, min_uV and max_uV will
> be NULL by default and UFS core driver will enable or disable the
> regulator only without adjusting its voltage.
>
> Acked-by: Avri Altman <[email protected]>
> Reviewed-by: Asutosh Das <[email protected]>
> Reviewed-by: Bjorn Andersson <[email protected]>

Reviewed-by: Can Guo <[email protected]>

> Signed-off-by: Stanley Chu <[email protected]>
> ---
> drivers/scsi/ufs/ufshcd-pltfrm.c | 19 -------------------
> 1 file changed, 19 deletions(-)
>
> diff --git a/drivers/scsi/ufs/ufshcd-pltfrm.c
> b/drivers/scsi/ufs/ufshcd-pltfrm.c
> index 0619cfbfbdbb..1a69949a4ea1 100644
> --- a/drivers/scsi/ufs/ufshcd-pltfrm.c
> +++ b/drivers/scsi/ufs/ufshcd-pltfrm.c
> @@ -134,25 +134,6 @@ static int ufshcd_populate_vreg(struct device
> *dev, const char *name,
> dev_info(dev, "%s: unable to find %s\n", __func__, prop_name);
> vreg->max_uA = 0;
> }
> -
> - if (!strcmp(name, "vcc")) {
> - if (of_property_read_bool(np, "vcc-supply-1p8")) {
> - vreg->min_uV = UFS_VREG_VCC_1P8_MIN_UV;
> - vreg->max_uV = UFS_VREG_VCC_1P8_MAX_UV;
> - } else {
> - vreg->min_uV = UFS_VREG_VCC_MIN_UV;
> - vreg->max_uV = UFS_VREG_VCC_MAX_UV;
> - }
> - } else if (!strcmp(name, "vccq")) {
> - vreg->min_uV = UFS_VREG_VCCQ_MIN_UV;
> - vreg->max_uV = UFS_VREG_VCCQ_MAX_UV;
> - } else if (!strcmp(name, "vccq2")) {
> - vreg->min_uV = UFS_VREG_VCCQ2_MIN_UV;
> - vreg->max_uV = UFS_VREG_VCCQ2_MAX_UV;
> - }
> -
> - goto out;
> -
> out:
> if (!ret)
> *out_vreg = vreg;

2020-12-07 23:17:56

by Martin K. Petersen

[permalink] [raw]
Subject: Re: [PATCH v3] scsi: ufs: Remove pre-defined initial voltage values of device powers


Stanley,

> UFS specficication allows different VCC configurations for UFS devices,
> for example,

Applied to 5.11/scsi-staging, thanks!

--
Martin K. Petersen Oracle Linux Engineering

2020-12-09 17:31:02

by Martin K. Petersen

[permalink] [raw]
Subject: Re: [PATCH v3] scsi: ufs: Remove pre-defined initial voltage values of device powers

On Wed, 2 Dec 2020 17:18:19 +0800, Stanley Chu wrote:

> UFS specficication allows different VCC configurations for UFS devices,
> for example,
> (1). 2.70V - 3.60V (Activated by default in UFS core driver)
> (2). 1.70V - 1.95V (Activated if "vcc-supply-1p8" is declared in
> device tree)
> (3). 2.40V - 2.70V (Supported since UFS 3.x)
>
> [...]

Applied to 5.11/scsi-queue, thanks!

[1/1] scsi: ufs: Remove pre-defined initial voltage values of device powers
https://git.kernel.org/mkp/scsi/c/5b44a07b6bb2

--
Martin K. Petersen Oracle Linux Engineering