From: Nina Wu <[email protected]>
For new ICs, there are multiple devapc HWs for different subsys.
We add a field 'vio-idx-num' in DT to indicate the number of
devices controlled by each devapc.
To be backward compatible with old ICs which have only one devapc
HW, this field is not required. The 'vio-idx-num' info will be set
in compatible data instead.
Reviewed-by: Rob Herring <[email protected]>
Signed-off-by: Nina Wu <[email protected]>
---
Documentation/devicetree/bindings/soc/mediatek/devapc.yaml | 5 +++++
1 file changed, 5 insertions(+)
diff --git a/Documentation/devicetree/bindings/soc/mediatek/devapc.yaml b/Documentation/devicetree/bindings/soc/mediatek/devapc.yaml
index 31e4d3c..69abd03 100644
--- a/Documentation/devicetree/bindings/soc/mediatek/devapc.yaml
+++ b/Documentation/devicetree/bindings/soc/mediatek/devapc.yaml
@@ -20,11 +20,16 @@ properties:
compatible:
enum:
- mediatek,mt6779-devapc
+ - mediatek,mt8192-devapc
reg:
description: The base address of devapc register bank
maxItems: 1
+ mediatek,vio-idx-num:
+ description: The number of the devices controlled by devapc
+ $ref: /schemas/types.yaml#/definitions/uint32
+
interrupts:
description: A single interrupt specifier
maxItems: 1
--
2.6.4