2004-01-26 15:38:00

by Jonathan Kamens

[permalink] [raw]
Subject: 2.6.2-rc1-mm3: SCSI TARGET RESET on boot with no indication of why

With my AIC7XXX controller and my rather old Microtek ScanMaker E6
SCSI scanner, 2.6.2-rc1-mm3 for some reason feels compelled to attempt
to reset the scanner immediately after identifying it during the boot
sequence. When I see "immediately" I mean that there doesn't seem to
be any delay between when it prints out the "Attached scsi generic"
message in the transcript below and when it prints out the subsequent
messages about the TARGET RESET message.

Despite these messages, the scanner appears to work when booting is
finished.

This does not occur with 2.4.22-ac4.

My question is -- do these messages indicate that something is wrong,
what could it be, and what should I do about it?

I tried to find a maintainer for the AIC7XXX code to contact about
this, but I didn't see one in MAINTAINERS.

Thanks,

jik

Boot log excerpt:

scsi0 : Adaptec AIC7XXX EISA/VLB/PCI SCSI HBA DRIVER, Rev 6.2.36
<Adaptec aic7890/91 Ultra2 SCSI adapter>
aic7890/91: Ultra2 Wide Channel A, SCSI Id=7, 32/253 SCBs

hub 1-0:1.0: new USB device on port 2, assigned address 3
Vendor: Model: Scanner 600 Rev: 1.91
Type: Scanner ANSI SCSI revision: 03
Attached scsi generic sg0 at scsi0, channel 0, id 4, lun 0, type 6
scsi0:0:4:0: Attempting to queue a TARGET RESET message
CDB: 0xa0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x4 0x8 0x0 0x0
scsi0:0:4:0: Command not found
aic7xxx_dev_reset returns 0x2002
scsi0:0:4:0: Attempting to queue a TARGET RESET message
CDB: 0xa0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x4 0x8 0x0 0x0
scsi0:0:4:0: Command not found
aic7xxx_dev_reset returns 0x2002
scsi0:0:4:0: Attempting to queue a TARGET RESET message
CDB: 0xa0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x4 0x8 0x0 0x0
scsi0:0:4:0: Command not found
aic7xxx_dev_reset returns 0x2002