Fix few trivial language typos.
Signed-off-by: Krzysztof Kozlowski <[email protected]>
---
drivers/power/supply/charger-manager.c | 18 +++++++++---------
1 file changed, 9 insertions(+), 9 deletions(-)
diff --git a/drivers/power/supply/charger-manager.c b/drivers/power/supply/charger-manager.c
index 38be91f21cc4..2e8db5e6de0b 100644
--- a/drivers/power/supply/charger-manager.c
+++ b/drivers/power/supply/charger-manager.c
@@ -4,7 +4,7 @@
*
* This driver enables to monitor battery health and control charger
* during suspend-to-mem.
- * Charger manager depends on other devices. register this later than
+ * Charger manager depends on other devices. Register this later than
* the depending devices.
*
* This program is free software; you can redistribute it and/or modify
@@ -29,7 +29,7 @@
#include <linux/thermal.h>
/*
- * Default termperature threshold for charging.
+ * Default temperature threshold for charging.
* Every temperature units are in tenth of centigrade.
*/
#define CM_DEFAULT_RECHARGE_TEMP_DIFF 50
@@ -356,7 +356,7 @@ static bool is_polling_required(struct charger_manager *cm)
* Note that Charger Manager keeps the charger enabled regardless whether
* the charger is charging or not (because battery is full or no external
* power source exists) except when CM needs to disable chargers forcibly
- * bacause of emergency causes; when the battery is overheated or too cold.
+ * because of emergency causes; when the battery is overheated or too cold.
*/
static int try_charger_enable(struct charger_manager *cm, bool enable)
{
@@ -643,7 +643,7 @@ static int cm_check_thermal_status(struct charger_manager *cm)
if (ret) {
/* FIXME:
* No information of battery temperature might
- * occur hazadous result. We have to handle it
+ * occur hazardous result. We have to handle it
* depending on battery type.
*/
dev_err(cm->dev, "Failed to get battery temperature\n");
@@ -693,7 +693,7 @@ static bool _cm_monitor(struct charger_manager *cm)
uevent_notify(cm, default_event_names[temp_alrt]);
/*
- * Check whole charging duration and discharing duration
+ * Check whole charging duration and discharging duration
* after full-batt.
*/
} else if (!cm->emergency_stop && check_charging_duration(cm)) {
@@ -866,7 +866,7 @@ static void battout_handler(struct charger_manager *cm)
}
/**
- * misc_event_handler - Handler for other evnets
+ * misc_event_handler - Handler for other events
* @cm: the Charger Manager representing the battery.
* @type: the Charger Manager representing the battery.
*/
@@ -1218,7 +1218,7 @@ static int charger_extcon_init(struct charger_manager *cm,
}
/**
- * charger_manager_register_extcon - Register extcon device to recevie state
+ * charger_manager_register_extcon - Register extcon device to receive state
* of charger cable.
* @cm: the Charger Manager representing the battery.
*
@@ -1538,7 +1538,7 @@ static struct charger_desc *of_cm_parse_desc(struct device *dev)
of_property_read_u32(np, "cm-discharging-max",
&desc->discharging_max_duration_ms);
- /* battery charger regualtors */
+ /* battery charger regulators */
desc->num_charger_regulators = of_get_child_count(np);
if (desc->num_charger_regulators) {
struct charger_regulator *chg_regs;
@@ -1801,7 +1801,7 @@ static int charger_manager_probe(struct platform_device *pdev)
/*
* Charger-manager have to check the charging state right after
- * tialization of charger-manager and then update current charging
+ * initialization of charger-manager and then update current charging
* state.
*/
cm_monitor();
--
2.7.4
Hi,
On Tue, Jan 08, 2019 at 01:12:12PM +0100, Krzysztof Kozlowski wrote:
> Fix few trivial language typos.
>
> Signed-off-by: Krzysztof Kozlowski <[email protected]>
> ---
Thanks, queued.
-- Sebastian
> drivers/power/supply/charger-manager.c | 18 +++++++++---------
> 1 file changed, 9 insertions(+), 9 deletions(-)
>
> diff --git a/drivers/power/supply/charger-manager.c b/drivers/power/supply/charger-manager.c
> index 38be91f21cc4..2e8db5e6de0b 100644
> --- a/drivers/power/supply/charger-manager.c
> +++ b/drivers/power/supply/charger-manager.c
> @@ -4,7 +4,7 @@
> *
> * This driver enables to monitor battery health and control charger
> * during suspend-to-mem.
> - * Charger manager depends on other devices. register this later than
> + * Charger manager depends on other devices. Register this later than
> * the depending devices.
> *
> * This program is free software; you can redistribute it and/or modify
> @@ -29,7 +29,7 @@
> #include <linux/thermal.h>
>
> /*
> - * Default termperature threshold for charging.
> + * Default temperature threshold for charging.
> * Every temperature units are in tenth of centigrade.
> */
> #define CM_DEFAULT_RECHARGE_TEMP_DIFF 50
> @@ -356,7 +356,7 @@ static bool is_polling_required(struct charger_manager *cm)
> * Note that Charger Manager keeps the charger enabled regardless whether
> * the charger is charging or not (because battery is full or no external
> * power source exists) except when CM needs to disable chargers forcibly
> - * bacause of emergency causes; when the battery is overheated or too cold.
> + * because of emergency causes; when the battery is overheated or too cold.
> */
> static int try_charger_enable(struct charger_manager *cm, bool enable)
> {
> @@ -643,7 +643,7 @@ static int cm_check_thermal_status(struct charger_manager *cm)
> if (ret) {
> /* FIXME:
> * No information of battery temperature might
> - * occur hazadous result. We have to handle it
> + * occur hazardous result. We have to handle it
> * depending on battery type.
> */
> dev_err(cm->dev, "Failed to get battery temperature\n");
> @@ -693,7 +693,7 @@ static bool _cm_monitor(struct charger_manager *cm)
> uevent_notify(cm, default_event_names[temp_alrt]);
>
> /*
> - * Check whole charging duration and discharing duration
> + * Check whole charging duration and discharging duration
> * after full-batt.
> */
> } else if (!cm->emergency_stop && check_charging_duration(cm)) {
> @@ -866,7 +866,7 @@ static void battout_handler(struct charger_manager *cm)
> }
>
> /**
> - * misc_event_handler - Handler for other evnets
> + * misc_event_handler - Handler for other events
> * @cm: the Charger Manager representing the battery.
> * @type: the Charger Manager representing the battery.
> */
> @@ -1218,7 +1218,7 @@ static int charger_extcon_init(struct charger_manager *cm,
> }
>
> /**
> - * charger_manager_register_extcon - Register extcon device to recevie state
> + * charger_manager_register_extcon - Register extcon device to receive state
> * of charger cable.
> * @cm: the Charger Manager representing the battery.
> *
> @@ -1538,7 +1538,7 @@ static struct charger_desc *of_cm_parse_desc(struct device *dev)
> of_property_read_u32(np, "cm-discharging-max",
> &desc->discharging_max_duration_ms);
>
> - /* battery charger regualtors */
> + /* battery charger regulators */
> desc->num_charger_regulators = of_get_child_count(np);
> if (desc->num_charger_regulators) {
> struct charger_regulator *chg_regs;
> @@ -1801,7 +1801,7 @@ static int charger_manager_probe(struct platform_device *pdev)
>
> /*
> * Charger-manager have to check the charging state right after
> - * tialization of charger-manager and then update current charging
> + * initialization of charger-manager and then update current charging
> * state.
> */
> cm_monitor();
> --
> 2.7.4
>