2021-03-04 06:36:41

by Henning Schild

[permalink] [raw]
Subject: [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs

From: Henning Schild <[email protected]>

This driver adds initial support for several devices from Siemens. It is
based on a platform driver introduced in an earlier commit.

Signed-off-by: Gerd Haeussler <[email protected]>
Signed-off-by: Henning Schild <[email protected]>
---
drivers/watchdog/Kconfig | 11 ++
drivers/watchdog/Makefile | 1 +
drivers/watchdog/simatic-ipc-wdt.c | 305 +++++++++++++++++++++++++++++
3 files changed, 317 insertions(+)
create mode 100644 drivers/watchdog/simatic-ipc-wdt.c

diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
index 1fe0042a48d2..948497eb4bef 100644
--- a/drivers/watchdog/Kconfig
+++ b/drivers/watchdog/Kconfig
@@ -1575,6 +1575,17 @@ config NIC7018_WDT
To compile this driver as a module, choose M here: the module will be
called nic7018_wdt.

+config SIEMENS_SIMATIC_IPC_WDT
+ tristate "Siemens Simatic IPC Watchdog"
+ depends on SIEMENS_SIMATIC_IPC
+ select WATCHDOG_CORE
+ help
+ This driver adds support for several watchdogs found in Industrial
+ PCs from Siemens.
+
+ To compile this driver as a module, choose M here: the module will be
+ called simatic-ipc-wdt.
+
# M68K Architecture

config M54xx_WATCHDOG
diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile
index f3a6540e725e..7f5c73ec058c 100644
--- a/drivers/watchdog/Makefile
+++ b/drivers/watchdog/Makefile
@@ -142,6 +142,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o
obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o
obj-$(CONFIG_MLX_WDT) += mlx_wdt.o
obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o
+obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o

# M68K Architecture
obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o
diff --git a/drivers/watchdog/simatic-ipc-wdt.c b/drivers/watchdog/simatic-ipc-wdt.c
new file mode 100644
index 000000000000..b5c8b7ceb404
--- /dev/null
+++ b/drivers/watchdog/simatic-ipc-wdt.c
@@ -0,0 +1,305 @@
+// SPDX-License-Identifier: GPL-2.0
+/*
+ * Siemens SIMATIC IPC driver for Watchdogs
+ *
+ * Copyright (c) Siemens AG, 2020-2021
+ *
+ * Authors:
+ * Gerd Haeussler <[email protected]>
+ *
+ * This program is free software; you can redistribute it and/or modify
+ * it under the terms of the GNU General Public License version 2 as
+ * published by the Free Software Foundation.
+ */
+
+#include <linux/device.h>
+#include <linux/init.h>
+#include <linux/kernel.h>
+#include <linux/module.h>
+#include <linux/platform_device.h>
+#include <linux/errno.h>
+#include <linux/watchdog.h>
+#include <linux/ioport.h>
+#include <linux/sizes.h>
+#include <linux/io.h>
+#include <linux/platform_data/x86/simatic-ipc-base.h>
+
+#define WD_ENABLE_IOADR 0x62
+#define WD_TRIGGER_IOADR 0x66
+#define GPIO_COMMUNITY0_PORT_ID 0xaf
+#define PAD_CFG_DW0_GPP_A_23 0x4b8
+#define SAFE_EN_N_427E 0x01
+#define SAFE_EN_N_227E 0x04
+#define WD_ENABLED 0x01
+
+#define TIMEOUT_MIN 2
+#define TIMEOUT_DEF 64
+#define TIMEOUT_MAX 64
+
+#define GP_STATUS_REG_227E 0x404D /* IO PORT for SAFE_EN_N on 227E */
+
+static bool nowayout = WATCHDOG_NOWAYOUT;
+module_param(nowayout, bool, 0000);
+MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default="
+ __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
+
+static DEFINE_SPINLOCK(io_lock); /* the lock for io operations */
+static struct watchdog_device wdd;
+
+static struct resource gp_status_reg_227e_res =
+ DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1, KBUILD_MODNAME);
+
+static struct resource io_resource =
+ DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
+ KBUILD_MODNAME " WD_ENABLE_IOADR");
+
+/* the actual start will be discovered with pci, 0 is a placeholder */
+static struct resource mem_resource =
+ DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR");
+
+static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
+static void __iomem *wd_reset_base_addr;
+
+static int get_timeout_idx(u32 timeout)
+{
+ int i;
+
+ i = ARRAY_SIZE(wd_timeout_table) - 1;
+ for (; i >= 0; i--) {
+ if (timeout >= wd_timeout_table[i])
+ break;
+ }
+
+ return i;
+}
+
+static int wd_start(struct watchdog_device *wdd)
+{
+ u8 regval;
+
+ spin_lock(&io_lock);
+
+ regval = inb(WD_ENABLE_IOADR);
+ regval |= WD_ENABLED;
+ outb(regval, WD_ENABLE_IOADR);
+
+ spin_unlock(&io_lock);
+
+ return 0;
+}
+
+static int wd_stop(struct watchdog_device *wdd)
+{
+ u8 regval;
+
+ spin_lock(&io_lock);
+
+ regval = inb(WD_ENABLE_IOADR);
+ regval &= ~WD_ENABLED;
+ outb(regval, WD_ENABLE_IOADR);
+
+ spin_unlock(&io_lock);
+
+ return 0;
+}
+
+static int wd_ping(struct watchdog_device *wdd)
+{
+ inb(WD_TRIGGER_IOADR);
+ return 0;
+}
+
+static int wd_set_timeout(struct watchdog_device *wdd, unsigned int t)
+{
+ u8 regval;
+ int timeout_idx = get_timeout_idx(t);
+
+ spin_lock(&io_lock);
+
+ regval = inb(WD_ENABLE_IOADR) & 0xc7;
+ regval |= timeout_idx << 3;
+ outb(regval, WD_ENABLE_IOADR);
+
+ spin_unlock(&io_lock);
+ wdd->timeout = wd_timeout_table[timeout_idx];
+
+ return 0;
+}
+
+static const struct watchdog_info wdt_ident = {
+ .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING |
+ WDIOF_SETTIMEOUT,
+ .identity = KBUILD_MODNAME,
+};
+
+static const struct watchdog_ops wdt_ops = {
+ .owner = THIS_MODULE,
+ .start = wd_start,
+ .stop = wd_stop,
+ .ping = wd_ping,
+ .set_timeout = wd_set_timeout,
+};
+
+static void wd_set_safe_en_n(u32 wdtmode, bool safe_en_n)
+{
+ u16 resetbit;
+
+ if (wdtmode == SIMATIC_IPC_DEVICE_227E) {
+ /* enable SAFE_EN_N on GP_STATUS_REG_227E */
+ resetbit = inw(GP_STATUS_REG_227E);
+ if (safe_en_n)
+ resetbit &= ~SAFE_EN_N_227E;
+ else
+ resetbit |= SAFE_EN_N_227E;
+
+ outw(resetbit, GP_STATUS_REG_227E);
+ } else {
+ /* enable SAFE_EN_N on PCH D1600 */
+ resetbit = ioread16(wd_reset_base_addr);
+
+ if (safe_en_n)
+ resetbit &= ~SAFE_EN_N_427E;
+ else
+ resetbit |= SAFE_EN_N_427E;
+
+ iowrite16(resetbit, wd_reset_base_addr);
+ }
+}
+
+static int wd_setup(u32 wdtmode, bool safe_en_n)
+{
+ u8 regval;
+ int timeout_idx = 0;
+ bool alarm_active;
+
+ timeout_idx = get_timeout_idx(TIMEOUT_DEF);
+
+ wd_set_safe_en_n(wdtmode, safe_en_n);
+
+ /* read wd register to determine alarm state */
+ regval = inb(WD_ENABLE_IOADR);
+ if (regval & 0x80) {
+ pr_warn("Watchdog alarm active.\n");
+ regval = 0x82; /* use only macro mode, reset alarm bit */
+ alarm_active = true;
+ } else {
+ regval = 0x02; /* use only macro mode */
+ alarm_active = false;
+ }
+
+ regval |= timeout_idx << 3;
+ if (nowayout)
+ regval |= WD_ENABLED;
+
+ outb(regval, WD_ENABLE_IOADR);
+
+ return alarm_active;
+}
+
+static int simatic_ipc_wdt_probe(struct platform_device *pdev)
+{
+ struct device *dev = &pdev->dev;
+ int rc = 0;
+ struct simatic_ipc_platform *plat = pdev->dev.platform_data;
+ struct resource *res;
+
+ pr_debug(KBUILD_MODNAME ":%s(#%d) WDT mode: %d\n",
+ __func__, __LINE__, plat->devmode);
+
+ switch (plat->devmode) {
+ case SIMATIC_IPC_DEVICE_227E:
+ if (!devm_request_region(dev, gp_status_reg_227e_res.start,
+ resource_size(&gp_status_reg_227e_res),
+ KBUILD_MODNAME)) {
+ dev_err(dev,
+ "Unable to register IO resource at %pR\n",
+ &gp_status_reg_227e_res);
+ return -EBUSY;
+ }
+ fallthrough;
+ case SIMATIC_IPC_DEVICE_427E:
+ wdd.info = &wdt_ident;
+ wdd.ops = &wdt_ops;
+ wdd.min_timeout = TIMEOUT_MIN;
+ wdd.max_timeout = TIMEOUT_MAX;
+ wdd.parent = NULL;
+ break;
+ default:
+ return -EINVAL;
+ }
+
+ if (!devm_request_region(dev, io_resource.start,
+ resource_size(&io_resource),
+ io_resource.name)) {
+ dev_err(dev,
+ "Unable to register IO resource at %#x\n",
+ WD_ENABLE_IOADR);
+ return -EBUSY;
+ }
+
+ if (plat->devmode == SIMATIC_IPC_DEVICE_427E) {
+ res = &mem_resource;
+
+ /* get GPIO base from PCI */
+ res->start = simatic_ipc_get_membase0(PCI_DEVFN(0x1f, 1));
+ if (res->start == 0)
+ return -ENODEV;
+
+ /* do the final address calculation */
+ res->start = res->start + (GPIO_COMMUNITY0_PORT_ID << 16) +
+ PAD_CFG_DW0_GPP_A_23;
+ res->end += res->start;
+
+ wd_reset_base_addr = devm_ioremap_resource(dev, res);
+ if (IS_ERR(wd_reset_base_addr))
+ return -ENOMEM;
+ }
+
+ wdd.bootstatus = wd_setup(plat->devmode, true);
+ if (wdd.bootstatus)
+ pr_warn(KBUILD_MODNAME ": last reboot caused by watchdog reset\n");
+
+ watchdog_set_nowayout(&wdd, nowayout);
+ watchdog_stop_on_reboot(&wdd);
+
+ rc = devm_watchdog_register_device(dev, &wdd);
+
+ if (rc == 0)
+ pr_debug("initialized. nowayout=%d\n",
+ nowayout);
+
+ return rc;
+}
+
+static int simatic_ipc_wdt_remove(struct platform_device *pdev)
+{
+ struct simatic_ipc_platform *plat = pdev->dev.platform_data;
+
+ wd_setup(plat->devmode, false);
+ return 0;
+}
+
+static struct platform_driver wdt_driver = {
+ .probe = simatic_ipc_wdt_probe,
+ .remove = simatic_ipc_wdt_remove,
+ .driver = {
+ .name = KBUILD_MODNAME,
+ },
+};
+
+static int __init simatic_ipc_wdt_init(void)
+{
+ return platform_driver_register(&wdt_driver);
+}
+
+static void __exit simatic_ipc_wdt_exit(void)
+{
+ platform_driver_unregister(&wdt_driver);
+}
+
+module_init(simatic_ipc_wdt_init);
+module_exit(simatic_ipc_wdt_exit);
+
+MODULE_LICENSE("GPL");
+MODULE_ALIAS("platform:" KBUILD_MODNAME);
+MODULE_AUTHOR("Gerd Haeussler <[email protected]>");
--
2.26.2


2021-03-04 11:07:02

by Henning Schild

[permalink] [raw]
Subject: Re: [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs

Hi,

thanks for the fast and thorough review!

Am Tue, 2 Mar 2021 10:38:19 -0800
schrieb Guenter Roeck <[email protected]>:

> On 3/2/21 8:33 AM, Henning Schild wrote:
> > From: Henning Schild <[email protected]>
> >
> > This driver adds initial support for several devices from Siemens.
> > It is based on a platform driver introduced in an earlier commit.
> >
> > Signed-off-by: Gerd Haeussler <[email protected]>
> > Signed-off-by: Henning Schild <[email protected]>
> > ---
> > drivers/watchdog/Kconfig | 11 ++
> > drivers/watchdog/Makefile | 1 +
> > drivers/watchdog/simatic-ipc-wdt.c | 305
> > +++++++++++++++++++++++++++++ 3 files changed, 317 insertions(+)
> > create mode 100644 drivers/watchdog/simatic-ipc-wdt.c
> >
> > diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
> > index 1fe0042a48d2..948497eb4bef 100644
> > --- a/drivers/watchdog/Kconfig
> > +++ b/drivers/watchdog/Kconfig
> > @@ -1575,6 +1575,17 @@ config NIC7018_WDT
> > To compile this driver as a module, choose M here: the
> > module will be called nic7018_wdt.
> >
> > +config SIEMENS_SIMATIC_IPC_WDT
> > + tristate "Siemens Simatic IPC Watchdog"
> > + depends on SIEMENS_SIMATIC_IPC
> > + select WATCHDOG_CORE
> > + help
> > + This driver adds support for several watchdogs found in
> > Industrial
> > + PCs from Siemens.
> > +
> > + To compile this driver as a module, choose M here: the
> > module will be
> > + called simatic-ipc-wdt.
> > +
> > # M68K Architecture
> >
> > config M54xx_WATCHDOG
> > diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile
> > index f3a6540e725e..7f5c73ec058c 100644
> > --- a/drivers/watchdog/Makefile
> > +++ b/drivers/watchdog/Makefile
> > @@ -142,6 +142,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o
> > obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o
> > obj-$(CONFIG_MLX_WDT) += mlx_wdt.o
> > obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o
> > +obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o
> >
> > # M68K Architecture
> > obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o
> > diff --git a/drivers/watchdog/simatic-ipc-wdt.c
> > b/drivers/watchdog/simatic-ipc-wdt.c new file mode 100644
> > index 000000000000..b5c8b7ceb404
> > --- /dev/null
> > +++ b/drivers/watchdog/simatic-ipc-wdt.c
> > @@ -0,0 +1,305 @@
> > +// SPDX-License-Identifier: GPL-2.0
> > +/*
> > + * Siemens SIMATIC IPC driver for Watchdogs
> > + *
> > + * Copyright (c) Siemens AG, 2020-2021
> > + *
> > + * Authors:
> > + * Gerd Haeussler <[email protected]>
> > + *
> > + * This program is free software; you can redistribute it and/or
> > modify
> > + * it under the terms of the GNU General Public License version 2
> > as
> > + * published by the Free Software Foundation.
>
> Covered by SPDX-License-Identifier
>
> > + */
> > +
> > +#include <linux/device.h>
> > +#include <linux/init.h>
> > +#include <linux/kernel.h>
> > +#include <linux/module.h>
> > +#include <linux/platform_device.h>
> > +#include <linux/errno.h>
> > +#include <linux/watchdog.h>
> > +#include <linux/ioport.h>
> > +#include <linux/sizes.h>> +#include <linux/io.h>
> > +#include <linux/platform_data/x86/simatic-ipc-base.h>
>
> Alphabetic order please
>
> > +
> > +#define WD_ENABLE_IOADR 0x62
> > +#define WD_TRIGGER_IOADR 0x66
> > +#define GPIO_COMMUNITY0_PORT_ID 0xaf
> > +#define PAD_CFG_DW0_GPP_A_23 0x4b8
>
> Please increase indentation and spare another tab
>
> > +#define SAFE_EN_N_427E 0x01
> > +#define SAFE_EN_N_227E 0x04
> > +#define WD_ENABLED 0x01
> > +
> > +#define TIMEOUT_MIN 2
> > +#define TIMEOUT_DEF 64
> > +#define TIMEOUT_MAX 64
> > +
> > +#define GP_STATUS_REG_227E 0x404D /* IO PORT for
> > SAFE_EN_N on 227E */ +
> > +static bool nowayout = WATCHDOG_NOWAYOUT;
> > +module_param(nowayout, bool, 0000);
> > +MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once
> > started (default="
> > + __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
> > +
> > +static DEFINE_SPINLOCK(io_lock); /* the lock for io
> > operations */ +static struct watchdog_device wdd;
> > +
>
> Having two variables named 'wdd' is confusing. Please chose another
> name.
>
> > +static struct resource gp_status_reg_227e_res =
> > + DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1,
> > KBUILD_MODNAME); +
> > +static struct resource io_resource =
> > + DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
> > + KBUILD_MODNAME " WD_ENABLE_IOADR");
> > +
> > +/* the actual start will be discovered with pci, 0 is a
> > placeholder */ +static struct resource mem_resource =
> > + DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR");
> > +
> > +static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
> > +static void __iomem *wd_reset_base_addr;
> > +
> > +static int get_timeout_idx(u32 timeout)
> > +{
> > + int i;
> > +
> > + i = ARRAY_SIZE(wd_timeout_table) - 1;
> > + for (; i >= 0; i--) {
> > + if (timeout >= wd_timeout_table[i])
> > + break;
> > + }
> > +
> > + return i;
> > +}
>
> Please add a comment explaining why you don't use find_closest().

Will not be a comment but we will switch to using this, thanks for
pointing it out.

> > +
> > +static int wd_start(struct watchdog_device *wdd)
> > +{
> > + u8 regval;
> > +
> > + spin_lock(&io_lock);
> > +
> The watchdog subsystem already provides locking
> since the watchdog device can only be opened once.
>
> Why is the additional lock needed ?

We had this under internal review and somehow came to the conclusion
that we "might" need it. I think we will remove it or come back with
reasons.

> > + regval = inb(WD_ENABLE_IOADR);
> > + regval |= WD_ENABLED;
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + spin_unlock(&io_lock);
> > +
> > + return 0;
> > +}
> > +
> > +static int wd_stop(struct watchdog_device *wdd)
> > +{
> > + u8 regval;
> > +
> > + spin_lock(&io_lock);
> > +
> > + regval = inb(WD_ENABLE_IOADR);
> > + regval &= ~WD_ENABLED;
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + spin_unlock(&io_lock);
> > +
> > + return 0;
> > +}
> > +
> > +static int wd_ping(struct watchdog_device *wdd)
> > +{
> > + inb(WD_TRIGGER_IOADR);
> > + return 0;
> > +}
> > +
> > +static int wd_set_timeout(struct watchdog_device *wdd, unsigned
> > int t) +{
> > + u8 regval;
> > + int timeout_idx = get_timeout_idx(t);
> > +
> > + spin_lock(&io_lock);
> > +
> > + regval = inb(WD_ENABLE_IOADR) & 0xc7;
> > + regval |= timeout_idx << 3;
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + spin_unlock(&io_lock);
> > + wdd->timeout = wd_timeout_table[timeout_idx];
> > +
> > + return 0;
> > +}
> > +
> > +static const struct watchdog_info wdt_ident = {
> > + .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING |
> > + WDIOF_SETTIMEOUT,
> > + .identity = KBUILD_MODNAME,
> > +};
> > +
> > +static const struct watchdog_ops wdt_ops = {
> > + .owner = THIS_MODULE,
> > + .start = wd_start,
> > + .stop = wd_stop,
> > + .ping = wd_ping,
> > + .set_timeout = wd_set_timeout,
> > +};
> > +
> > +static void wd_set_safe_en_n(u32 wdtmode, bool safe_en_n)
> > +{
> > + u16 resetbit;
> > +
> > + if (wdtmode == SIMATIC_IPC_DEVICE_227E) {
> > + /* enable SAFE_EN_N on GP_STATUS_REG_227E */
> > + resetbit = inw(GP_STATUS_REG_227E);
> > + if (safe_en_n)
> > + resetbit &= ~SAFE_EN_N_227E;
> > + else
> > + resetbit |= SAFE_EN_N_227E;
> > +
> > + outw(resetbit, GP_STATUS_REG_227E);
> > + } else {
> > + /* enable SAFE_EN_N on PCH D1600 */
> > + resetbit = ioread16(wd_reset_base_addr);
> > +
> > + if (safe_en_n)
> > + resetbit &= ~SAFE_EN_N_427E;
> > + else
> > + resetbit |= SAFE_EN_N_427E;
> > +
> > + iowrite16(resetbit, wd_reset_base_addr);
> > + }
> > +}
> > +
> > +static int wd_setup(u32 wdtmode, bool safe_en_n)
> > +{
> > + u8 regval;
> > + int timeout_idx = 0;
>
> Unnecessary initialization
>
> > + bool alarm_active;
> > +
> > + timeout_idx = get_timeout_idx(TIMEOUT_DEF);
> > +
> > + wd_set_safe_en_n(wdtmode, safe_en_n);
> > +
> > + /* read wd register to determine alarm state */
> > + regval = inb(WD_ENABLE_IOADR);
> > + if (regval & 0x80) {
> > + pr_warn("Watchdog alarm active.\n");
>
> Why does that warrant a warning, and what does it mean ? The context
> suggests that it means the previous reset was caused by the watchdog,
> but that is not what the message says.
>
> > + regval = 0x82; /* use only macro mode,
> > reset alarm bit */
> > + alarm_active = true;
> > + } else {
> > + regval = 0x02; /* use only macro mode */
> > + alarm_active = false;
> > + }
>
> Would it hurt to just always write 0x82 ?
> alarm_active = regval & 0x80;
> regval = 0x82 | timeout_idx << 3;
>
> would be much simpler. Or, if you prefer,
> alarm_active = !!(regval & 0x80);
> regval = 0x82 | timeout_idx << 3;
>
> Actually, regval isn't even needed in that case.
> alarm_active = !!(regval & 0x80);
> outb(0x82 | timeout_idx << 3, WD_ENABLE_IOADR);
>
>
> Either case, please use defines for the bits. WD_ENABLED is already
> defined, thus the other bits should be set using defines as well.
>
> > +
> > + regval |= timeout_idx << 3;
> > + if (nowayout)
> > + regval |= WD_ENABLED;
>
> This is not the purpose of nowayout. nowayout prevents stopping
> the watchdog after it has been started. It is not expected to start
> the watchdog on boot.

Thanks, that was misunderstood by the author, will fix.

> > +
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + return alarm_active;
> > +}
> > +
> > +static int simatic_ipc_wdt_probe(struct platform_device *pdev)
> > +{
> > + struct device *dev = &pdev->dev;
> > + int rc = 0;
> > + struct simatic_ipc_platform *plat =
> > pdev->dev.platform_data;
> > + struct resource *res;
> > +
>
> Is it guaranteed that the device will always be instantiated only
> once ? If so, how it it guaranteed ?

I suppose if anything did register two platform devices on the platform
bus this might not be guaranteed. The assumption is that simatic-ipc
will only ever register one, and the machines always have 0-1 "Siemens
watchdogs" so at the moment there will never be a need for more than
one.

> Because if there are ever multiple instances the various static
> variables will cause major trouble (which is why it is always better
> to not use static variables).
>
> > + pr_debug(KBUILD_MODNAME ":%s(#%d) WDT mode: %d\n",
> > + __func__, __LINE__, plat->devmode);
> > +
>
> This is a platform device. Please use dev_ messages (dev_warn,
> dev_dbg etc) throughout.
>
> > + switch (plat->devmode) {
> > + case SIMATIC_IPC_DEVICE_227E:
> > + if (!devm_request_region(dev,
> > gp_status_reg_227e_res.start,
> > +
> > resource_size(&gp_status_reg_227e_res),
> > + KBUILD_MODNAME)) {
> > + dev_err(dev,
> > + "Unable to register IO resource at
> > %pR\n",
> > + &gp_status_reg_227e_res);
> > + return -EBUSY;
> > + }
> > + fallthrough;
> > + case SIMATIC_IPC_DEVICE_427E:
> > + wdd.info = &wdt_ident;
> > + wdd.ops = &wdt_ops;
> > + wdd.min_timeout = TIMEOUT_MIN;
> > + wdd.max_timeout = TIMEOUT_MAX;
>
> Why not use static initialization ?
>
> > + wdd.parent = NULL;
>
> parent should be the platform device.
>
> > + break;
> > + default:
> > + return -EINVAL;
> > + }
> > +
> > + if (!devm_request_region(dev, io_resource.start,
> > + resource_size(&io_resource),
> > + io_resource.name)) {
> > + dev_err(dev,
> > + "Unable to register IO resource at %#x\n",
> > + WD_ENABLE_IOADR);
> > + return -EBUSY;
> > + }
>
> If this is what prevents multiple registrations, it is too late: wdd
> is already overwritten.

As said, there will be no double-registration.

> > +
> > + if (plat->devmode == SIMATIC_IPC_DEVICE_427E) {
> > + res = &mem_resource;
> > +
> > + /* get GPIO base from PCI */
> > + res->start =
> > simatic_ipc_get_membase0(PCI_DEVFN(0x1f, 1));
> > + if (res->start == 0)
> > + return -ENODEV;
> > +
> > + /* do the final address calculation */
> > + res->start = res->start + (GPIO_COMMUNITY0_PORT_ID
> > << 16) +
> > + PAD_CFG_DW0_GPP_A_23;
> > + res->end += res->start;
> > +
> > + wd_reset_base_addr = devm_ioremap_resource(dev,
> > res);
> > + if (IS_ERR(wd_reset_base_addr))
> > + return -ENOMEM;
>
> return PTR_ERR(wd_reset_base_addr);
>
> > + }
> > +
> > + wdd.bootstatus = wd_setup(plat->devmode, true);
>
> bootstatus does not report a boolean. This translates to
> WDIOF_OVERHEAT which is almost certainly wrong.
>
> > + if (wdd.bootstatus)
> > + pr_warn(KBUILD_MODNAME ": last reboot caused by
> > watchdog reset\n");
>
> Why two messages ?
>
> > +
> > + watchdog_set_nowayout(&wdd, nowayout);
> > + watchdog_stop_on_reboot(&wdd);
> > +
> > + rc = devm_watchdog_register_device(dev, &wdd);
> > +
> Extra empty line not needed
>
> > + if (rc == 0)
> > + pr_debug("initialized. nowayout=%d\n",
> > + nowayout);
>
> What is the value of this message (especially since there is no
> message if there is an error) ?
>
> > +
> > + return rc;
> > +}
> > +
> > +static int simatic_ipc_wdt_remove(struct platform_device *pdev)
> > +{
> > + struct simatic_ipc_platform *plat =
> > pdev->dev.platform_data; +
> > + wd_setup(plat->devmode, false);
>
> This warrants an explanation. What is the point of updating the
> timeout here ? And what does SAFE_EN actually do ?

The idea was that module unloading should disable the watchdog, but
that code will be removed and aligned with other watchdogs.

SAFE_EN is a second enable bit, if it is not set the watchdog will fire
into the void. Pretty pointless will keep that always armed or set it
always when toggling "enable".

All the other open points are pretty clear, and will all be dealt with
in v2.

regards,
Henning

> The watchdog is stopped on reboot, but this function won't
> be called in that case, making this call even more questionable.
> Please document what it does and why it is needed here (but not
> when rebooting).
>
> > + return 0;
> > +}
> > +
> > +static struct platform_driver wdt_driver = {
> > + .probe = simatic_ipc_wdt_probe,
> > + .remove = simatic_ipc_wdt_remove,
> > + .driver = {
> > + .name = KBUILD_MODNAME,
> > + },
> > +};
> > +
> > +static int __init simatic_ipc_wdt_init(void)
> > +{
> > + return platform_driver_register(&wdt_driver);
> > +}
> > +
> > +static void __exit simatic_ipc_wdt_exit(void)
> > +{
> > + platform_driver_unregister(&wdt_driver);
> > +}
> > +
> > +module_init(simatic_ipc_wdt_init);
> > +module_exit(simatic_ipc_wdt_exit);
>
> Why not module_platform_driver() ?
>
> > +
> > +MODULE_LICENSE("GPL");
> > +MODULE_ALIAS("platform:" KBUILD_MODNAME);
> > +MODULE_AUTHOR("Gerd Haeussler <[email protected]>");
> >
>

2021-03-04 11:17:02

by Jan Kiszka

[permalink] [raw]
Subject: Re: [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs

On 03.03.21 15:21, Henning Schild wrote:
> Hi,
>
> thanks for the fast and thorough review!
>
> Am Tue, 2 Mar 2021 10:38:19 -0800
> schrieb Guenter Roeck <[email protected]>:
>
>> On 3/2/21 8:33 AM, Henning Schild wrote:
>>> From: Henning Schild <[email protected]>
>>>
>>> This driver adds initial support for several devices from Siemens.
>>> It is based on a platform driver introduced in an earlier commit.
>>>
>>> Signed-off-by: Gerd Haeussler <[email protected]>
>>> Signed-off-by: Henning Schild <[email protected]>
>>> ---
>>> drivers/watchdog/Kconfig | 11 ++
>>> drivers/watchdog/Makefile | 1 +
>>> drivers/watchdog/simatic-ipc-wdt.c | 305
>>> +++++++++++++++++++++++++++++ 3 files changed, 317 insertions(+)
>>> create mode 100644 drivers/watchdog/simatic-ipc-wdt.c
>>>
>>> diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
>>> index 1fe0042a48d2..948497eb4bef 100644
>>> --- a/drivers/watchdog/Kconfig
>>> +++ b/drivers/watchdog/Kconfig
>>> @@ -1575,6 +1575,17 @@ config NIC7018_WDT
>>> To compile this driver as a module, choose M here: the
>>> module will be called nic7018_wdt.
>>>
>>> +config SIEMENS_SIMATIC_IPC_WDT
>>> + tristate "Siemens Simatic IPC Watchdog"
>>> + depends on SIEMENS_SIMATIC_IPC
>>> + select WATCHDOG_CORE
>>> + help
>>> + This driver adds support for several watchdogs found in
>>> Industrial
>>> + PCs from Siemens.
>>> +
>>> + To compile this driver as a module, choose M here: the
>>> module will be
>>> + called simatic-ipc-wdt.
>>> +
>>> # M68K Architecture
>>>
>>> config M54xx_WATCHDOG
>>> diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile
>>> index f3a6540e725e..7f5c73ec058c 100644
>>> --- a/drivers/watchdog/Makefile
>>> +++ b/drivers/watchdog/Makefile
>>> @@ -142,6 +142,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o
>>> obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o
>>> obj-$(CONFIG_MLX_WDT) += mlx_wdt.o
>>> obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o
>>> +obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o
>>>
>>> # M68K Architecture
>>> obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o
>>> diff --git a/drivers/watchdog/simatic-ipc-wdt.c
>>> b/drivers/watchdog/simatic-ipc-wdt.c new file mode 100644
>>> index 000000000000..b5c8b7ceb404
>>> --- /dev/null
>>> +++ b/drivers/watchdog/simatic-ipc-wdt.c
>>> @@ -0,0 +1,305 @@
>>> +// SPDX-License-Identifier: GPL-2.0
>>> +/*
>>> + * Siemens SIMATIC IPC driver for Watchdogs
>>> + *
>>> + * Copyright (c) Siemens AG, 2020-2021
>>> + *
>>> + * Authors:
>>> + * Gerd Haeussler <[email protected]>
>>> + *
>>> + * This program is free software; you can redistribute it and/or
>>> modify
>>> + * it under the terms of the GNU General Public License version 2
>>> as
>>> + * published by the Free Software Foundation.
>>
>> Covered by SPDX-License-Identifier
>>
>>> + */
>>> +
>>> +#include <linux/device.h>
>>> +#include <linux/init.h>
>>> +#include <linux/kernel.h>
>>> +#include <linux/module.h>
>>> +#include <linux/platform_device.h>
>>> +#include <linux/errno.h>
>>> +#include <linux/watchdog.h>
>>> +#include <linux/ioport.h>
>>> +#include <linux/sizes.h>> +#include <linux/io.h>
>>> +#include <linux/platform_data/x86/simatic-ipc-base.h>
>>
>> Alphabetic order please
>>
>>> +
>>> +#define WD_ENABLE_IOADR 0x62
>>> +#define WD_TRIGGER_IOADR 0x66
>>> +#define GPIO_COMMUNITY0_PORT_ID 0xaf
>>> +#define PAD_CFG_DW0_GPP_A_23 0x4b8
>>
>> Please increase indentation and spare another tab
>>
>>> +#define SAFE_EN_N_427E 0x01
>>> +#define SAFE_EN_N_227E 0x04
>>> +#define WD_ENABLED 0x01
>>> +
>>> +#define TIMEOUT_MIN 2
>>> +#define TIMEOUT_DEF 64
>>> +#define TIMEOUT_MAX 64
>>> +
>>> +#define GP_STATUS_REG_227E 0x404D /* IO PORT for
>>> SAFE_EN_N on 227E */ +
>>> +static bool nowayout = WATCHDOG_NOWAYOUT;
>>> +module_param(nowayout, bool, 0000);
>>> +MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once
>>> started (default="
>>> + __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
>>> +
>>> +static DEFINE_SPINLOCK(io_lock); /* the lock for io
>>> operations */ +static struct watchdog_device wdd;
>>> +
>>
>> Having two variables named 'wdd' is confusing. Please chose another
>> name.
>>
>>> +static struct resource gp_status_reg_227e_res =
>>> + DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1,
>>> KBUILD_MODNAME); +
>>> +static struct resource io_resource =
>>> + DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
>>> + KBUILD_MODNAME " WD_ENABLE_IOADR");
>>> +
>>> +/* the actual start will be discovered with pci, 0 is a
>>> placeholder */ +static struct resource mem_resource =
>>> + DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR");
>>> +
>>> +static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
>>> +static void __iomem *wd_reset_base_addr;
>>> +
>>> +static int get_timeout_idx(u32 timeout)
>>> +{
>>> + int i;
>>> +
>>> + i = ARRAY_SIZE(wd_timeout_table) - 1;
>>> + for (; i >= 0; i--) {
>>> + if (timeout >= wd_timeout_table[i])
>>> + break;
>>> + }
>>> +
>>> + return i;
>>> +}
>>
>> Please add a comment explaining why you don't use find_closest().
>
> Will not be a comment but we will switch to using this, thanks for
> pointing it out.
>
>>> +
>>> +static int wd_start(struct watchdog_device *wdd)
>>> +{
>>> + u8 regval;
>>> +
>>> + spin_lock(&io_lock);
>>> +
>> The watchdog subsystem already provides locking
>> since the watchdog device can only be opened once.
>>
>> Why is the additional lock needed ?
>
> We had this under internal review and somehow came to the conclusion
> that we "might" need it. I think we will remove it or come back with
> reasons.

Probably my fault. I quickly scanned for locking usage in other watchdog
drivers and found plenty of those RMW-protecting locks. I didn't check
then what the actual locking model of the watchdog core is, and possibly
some of the other use cases need to protect register against other users
or multiple watchdog instances. But if the core locks
start/stop/set_timeout internally against each other, this is obviously
pointless without out inherently single-instance use case here.

Jan

--
Siemens AG, T RDA IOT
Corporate Competence Center Embedded Linux

2021-03-04 20:29:24

by Guenter Roeck

[permalink] [raw]
Subject: Re: [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs

On 3/2/21 8:33 AM, Henning Schild wrote:
> From: Henning Schild <[email protected]>
>
> This driver adds initial support for several devices from Siemens. It is
> based on a platform driver introduced in an earlier commit.
>
> Signed-off-by: Gerd Haeussler <[email protected]>
> Signed-off-by: Henning Schild <[email protected]>
> ---
> drivers/watchdog/Kconfig | 11 ++
> drivers/watchdog/Makefile | 1 +
> drivers/watchdog/simatic-ipc-wdt.c | 305 +++++++++++++++++++++++++++++
> 3 files changed, 317 insertions(+)
> create mode 100644 drivers/watchdog/simatic-ipc-wdt.c
>
> diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
> index 1fe0042a48d2..948497eb4bef 100644
> --- a/drivers/watchdog/Kconfig
> +++ b/drivers/watchdog/Kconfig
> @@ -1575,6 +1575,17 @@ config NIC7018_WDT
> To compile this driver as a module, choose M here: the module will be
> called nic7018_wdt.
>
> +config SIEMENS_SIMATIC_IPC_WDT
> + tristate "Siemens Simatic IPC Watchdog"
> + depends on SIEMENS_SIMATIC_IPC
> + select WATCHDOG_CORE
> + help
> + This driver adds support for several watchdogs found in Industrial
> + PCs from Siemens.
> +
> + To compile this driver as a module, choose M here: the module will be
> + called simatic-ipc-wdt.
> +
> # M68K Architecture
>
> config M54xx_WATCHDOG
> diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile
> index f3a6540e725e..7f5c73ec058c 100644
> --- a/drivers/watchdog/Makefile
> +++ b/drivers/watchdog/Makefile
> @@ -142,6 +142,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o
> obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o
> obj-$(CONFIG_MLX_WDT) += mlx_wdt.o
> obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o
> +obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o
>
> # M68K Architecture
> obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o
> diff --git a/drivers/watchdog/simatic-ipc-wdt.c b/drivers/watchdog/simatic-ipc-wdt.c
> new file mode 100644
> index 000000000000..b5c8b7ceb404
> --- /dev/null
> +++ b/drivers/watchdog/simatic-ipc-wdt.c
> @@ -0,0 +1,305 @@
> +// SPDX-License-Identifier: GPL-2.0
> +/*
> + * Siemens SIMATIC IPC driver for Watchdogs
> + *
> + * Copyright (c) Siemens AG, 2020-2021
> + *
> + * Authors:
> + * Gerd Haeussler <[email protected]>
> + *
> + * This program is free software; you can redistribute it and/or modify
> + * it under the terms of the GNU General Public License version 2 as
> + * published by the Free Software Foundation.

Covered by SPDX-License-Identifier

> + */
> +
> +#include <linux/device.h>
> +#include <linux/init.h>
> +#include <linux/kernel.h>
> +#include <linux/module.h>
> +#include <linux/platform_device.h>
> +#include <linux/errno.h>
> +#include <linux/watchdog.h>
> +#include <linux/ioport.h>
> +#include <linux/sizes.h>> +#include <linux/io.h>
> +#include <linux/platform_data/x86/simatic-ipc-base.h>

Alphabetic order please

> +
> +#define WD_ENABLE_IOADR 0x62
> +#define WD_TRIGGER_IOADR 0x66
> +#define GPIO_COMMUNITY0_PORT_ID 0xaf
> +#define PAD_CFG_DW0_GPP_A_23 0x4b8

Please increase indentation and spare another tab

> +#define SAFE_EN_N_427E 0x01
> +#define SAFE_EN_N_227E 0x04
> +#define WD_ENABLED 0x01
> +
> +#define TIMEOUT_MIN 2
> +#define TIMEOUT_DEF 64
> +#define TIMEOUT_MAX 64
> +
> +#define GP_STATUS_REG_227E 0x404D /* IO PORT for SAFE_EN_N on 227E */
> +
> +static bool nowayout = WATCHDOG_NOWAYOUT;
> +module_param(nowayout, bool, 0000);
> +MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default="
> + __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
> +
> +static DEFINE_SPINLOCK(io_lock); /* the lock for io operations */
> +static struct watchdog_device wdd;
> +

Having two variables named 'wdd' is confusing. Please chose another name.

> +static struct resource gp_status_reg_227e_res =
> + DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1, KBUILD_MODNAME);
> +
> +static struct resource io_resource =
> + DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
> + KBUILD_MODNAME " WD_ENABLE_IOADR");
> +
> +/* the actual start will be discovered with pci, 0 is a placeholder */
> +static struct resource mem_resource =
> + DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR");
> +
> +static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
> +static void __iomem *wd_reset_base_addr;
> +
> +static int get_timeout_idx(u32 timeout)
> +{
> + int i;
> +
> + i = ARRAY_SIZE(wd_timeout_table) - 1;
> + for (; i >= 0; i--) {
> + if (timeout >= wd_timeout_table[i])
> + break;
> + }
> +
> + return i;
> +}

Please add a comment explaining why you don't use find_closest().

> +
> +static int wd_start(struct watchdog_device *wdd)
> +{
> + u8 regval;
> +
> + spin_lock(&io_lock);
> +
The watchdog subsystem already provides locking
since the watchdog device can only be opened once.

Why is the additional lock needed ?

> + regval = inb(WD_ENABLE_IOADR);
> + regval |= WD_ENABLED;
> + outb(regval, WD_ENABLE_IOADR);
> +
> + spin_unlock(&io_lock);
> +
> + return 0;
> +}
> +
> +static int wd_stop(struct watchdog_device *wdd)
> +{
> + u8 regval;
> +
> + spin_lock(&io_lock);
> +
> + regval = inb(WD_ENABLE_IOADR);
> + regval &= ~WD_ENABLED;
> + outb(regval, WD_ENABLE_IOADR);
> +
> + spin_unlock(&io_lock);
> +
> + return 0;
> +}
> +
> +static int wd_ping(struct watchdog_device *wdd)
> +{
> + inb(WD_TRIGGER_IOADR);
> + return 0;
> +}
> +
> +static int wd_set_timeout(struct watchdog_device *wdd, unsigned int t)
> +{
> + u8 regval;
> + int timeout_idx = get_timeout_idx(t);
> +
> + spin_lock(&io_lock);
> +
> + regval = inb(WD_ENABLE_IOADR) & 0xc7;
> + regval |= timeout_idx << 3;
> + outb(regval, WD_ENABLE_IOADR);
> +
> + spin_unlock(&io_lock);
> + wdd->timeout = wd_timeout_table[timeout_idx];
> +
> + return 0;
> +}
> +
> +static const struct watchdog_info wdt_ident = {
> + .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING |
> + WDIOF_SETTIMEOUT,
> + .identity = KBUILD_MODNAME,
> +};
> +
> +static const struct watchdog_ops wdt_ops = {
> + .owner = THIS_MODULE,
> + .start = wd_start,
> + .stop = wd_stop,
> + .ping = wd_ping,
> + .set_timeout = wd_set_timeout,
> +};
> +
> +static void wd_set_safe_en_n(u32 wdtmode, bool safe_en_n)
> +{
> + u16 resetbit;
> +
> + if (wdtmode == SIMATIC_IPC_DEVICE_227E) {
> + /* enable SAFE_EN_N on GP_STATUS_REG_227E */
> + resetbit = inw(GP_STATUS_REG_227E);
> + if (safe_en_n)
> + resetbit &= ~SAFE_EN_N_227E;
> + else
> + resetbit |= SAFE_EN_N_227E;
> +
> + outw(resetbit, GP_STATUS_REG_227E);
> + } else {
> + /* enable SAFE_EN_N on PCH D1600 */
> + resetbit = ioread16(wd_reset_base_addr);
> +
> + if (safe_en_n)
> + resetbit &= ~SAFE_EN_N_427E;
> + else
> + resetbit |= SAFE_EN_N_427E;
> +
> + iowrite16(resetbit, wd_reset_base_addr);
> + }
> +}
> +
> +static int wd_setup(u32 wdtmode, bool safe_en_n)
> +{
> + u8 regval;
> + int timeout_idx = 0;

Unnecessary initialization

> + bool alarm_active;
> +
> + timeout_idx = get_timeout_idx(TIMEOUT_DEF);
> +
> + wd_set_safe_en_n(wdtmode, safe_en_n);
> +
> + /* read wd register to determine alarm state */
> + regval = inb(WD_ENABLE_IOADR);
> + if (regval & 0x80) {
> + pr_warn("Watchdog alarm active.\n");

Why does that warrant a warning, and what does it mean ? The context suggests
that it means the previous reset was caused by the watchdog, but that is not
what the message says.

> + regval = 0x82; /* use only macro mode, reset alarm bit */
> + alarm_active = true;
> + } else {
> + regval = 0x02; /* use only macro mode */
> + alarm_active = false;
> + }

Would it hurt to just always write 0x82 ?
alarm_active = regval & 0x80;
regval = 0x82 | timeout_idx << 3;

would be much simpler. Or, if you prefer,
alarm_active = !!(regval & 0x80);
regval = 0x82 | timeout_idx << 3;

Actually, regval isn't even needed in that case.
alarm_active = !!(regval & 0x80);
outb(0x82 | timeout_idx << 3, WD_ENABLE_IOADR);


Either case, please use defines for the bits. WD_ENABLED is already
defined, thus the other bits should be set using defines as well.

> +
> + regval |= timeout_idx << 3;
> + if (nowayout)
> + regval |= WD_ENABLED;

This is not the purpose of nowayout. nowayout prevents stopping
the watchdog after it has been started. It is not expected to start
the watchdog on boot.

> +
> + outb(regval, WD_ENABLE_IOADR);
> +
> + return alarm_active;
> +}
> +
> +static int simatic_ipc_wdt_probe(struct platform_device *pdev)
> +{
> + struct device *dev = &pdev->dev;
> + int rc = 0;
> + struct simatic_ipc_platform *plat = pdev->dev.platform_data;
> + struct resource *res;
> +

Is it guaranteed that the device will always be instantiated only once ?
If so, how it it guaranteed ?

Because if there are ever multiple instances the various static variables
will cause major trouble (which is why it is always better to not use static
variables).

> + pr_debug(KBUILD_MODNAME ":%s(#%d) WDT mode: %d\n",
> + __func__, __LINE__, plat->devmode);
> +

This is a platform device. Please use dev_ messages (dev_warn, dev_dbg etc)
throughout.

> + switch (plat->devmode) {
> + case SIMATIC_IPC_DEVICE_227E:
> + if (!devm_request_region(dev, gp_status_reg_227e_res.start,
> + resource_size(&gp_status_reg_227e_res),
> + KBUILD_MODNAME)) {
> + dev_err(dev,
> + "Unable to register IO resource at %pR\n",
> + &gp_status_reg_227e_res);
> + return -EBUSY;
> + }
> + fallthrough;
> + case SIMATIC_IPC_DEVICE_427E:
> + wdd.info = &wdt_ident;
> + wdd.ops = &wdt_ops;
> + wdd.min_timeout = TIMEOUT_MIN;
> + wdd.max_timeout = TIMEOUT_MAX;

Why not use static initialization ?

> + wdd.parent = NULL;

parent should be the platform device.

> + break;
> + default:
> + return -EINVAL;
> + }
> +
> + if (!devm_request_region(dev, io_resource.start,
> + resource_size(&io_resource),
> + io_resource.name)) {
> + dev_err(dev,
> + "Unable to register IO resource at %#x\n",
> + WD_ENABLE_IOADR);
> + return -EBUSY;
> + }

If this is what prevents multiple registrations, it is too late: wdd
is already overwritten.

> +
> + if (plat->devmode == SIMATIC_IPC_DEVICE_427E) {
> + res = &mem_resource;
> +
> + /* get GPIO base from PCI */
> + res->start = simatic_ipc_get_membase0(PCI_DEVFN(0x1f, 1));
> + if (res->start == 0)
> + return -ENODEV;
> +
> + /* do the final address calculation */
> + res->start = res->start + (GPIO_COMMUNITY0_PORT_ID << 16) +
> + PAD_CFG_DW0_GPP_A_23;
> + res->end += res->start;
> +
> + wd_reset_base_addr = devm_ioremap_resource(dev, res);
> + if (IS_ERR(wd_reset_base_addr))
> + return -ENOMEM;

return PTR_ERR(wd_reset_base_addr);

> + }
> +
> + wdd.bootstatus = wd_setup(plat->devmode, true);

bootstatus does not report a boolean. This translates to WDIOF_OVERHEAT
which is almost certainly wrong.

> + if (wdd.bootstatus)
> + pr_warn(KBUILD_MODNAME ": last reboot caused by watchdog reset\n");

Why two messages ?

> +
> + watchdog_set_nowayout(&wdd, nowayout);
> + watchdog_stop_on_reboot(&wdd);
> +
> + rc = devm_watchdog_register_device(dev, &wdd);
> +
Extra empty line not needed

> + if (rc == 0)
> + pr_debug("initialized. nowayout=%d\n",
> + nowayout);

What is the value of this message (especially since there is no message
if there is an error) ?

> +
> + return rc;
> +}
> +
> +static int simatic_ipc_wdt_remove(struct platform_device *pdev)
> +{
> + struct simatic_ipc_platform *plat = pdev->dev.platform_data;
> +
> + wd_setup(plat->devmode, false);

This warrants an explanation. What is the point of updating the timeout
here ? And what does SAFE_EN actually do ?

The watchdog is stopped on reboot, but this function won't
be called in that case, making this call even more questionable.
Please document what it does and why it is needed here (but not
when rebooting).

> + return 0;
> +}
> +
> +static struct platform_driver wdt_driver = {
> + .probe = simatic_ipc_wdt_probe,
> + .remove = simatic_ipc_wdt_remove,
> + .driver = {
> + .name = KBUILD_MODNAME,
> + },
> +};
> +
> +static int __init simatic_ipc_wdt_init(void)
> +{
> + return platform_driver_register(&wdt_driver);
> +}
> +
> +static void __exit simatic_ipc_wdt_exit(void)
> +{
> + platform_driver_unregister(&wdt_driver);
> +}
> +
> +module_init(simatic_ipc_wdt_init);
> +module_exit(simatic_ipc_wdt_exit);

Why not module_platform_driver() ?

> +
> +MODULE_LICENSE("GPL");
> +MODULE_ALIAS("platform:" KBUILD_MODNAME);
> +MODULE_AUTHOR("Gerd Haeussler <[email protected]>");
>

2021-03-05 00:07:37

by Henning Schild

[permalink] [raw]
Subject: Re: [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs

Am Thu, 4 Mar 2021 10:27:07 +0200
schrieb Andy Shevchenko <[email protected]>:

> On Tuesday, March 2, 2021, Henning Schild <[email protected]>
> wrote:
>
> > From: Henning Schild <[email protected]>
> >
> > This driver adds initial support for several devices from Siemens.
> > It is based on a platform driver introduced in an earlier commit.
> >
> >
>
> Is it ACPI based? Why it can not provide WDAT table instead?

Yes it is. We strongly urged the BIOS guys to look into that for future
products and BIOS updates for current products. But for existing
products they will not add "features". One fear is breaking Windows
where custom drivers have been the way they did it so far.

So we are dealing with legacy here, that is why. Hope that is not a
show-stopper.

Maybe we can carry ACPI quirk snippets instead, did not yet look into
this. And i am not sure which version would be easier to maintain and
more acceptable to the kernel.

regards,
Henning

>
> > Signed-off-by: Gerd Haeussler <[email protected]>
> > Signed-off-by: Henning Schild <[email protected]>
> > ---
> > drivers/watchdog/Kconfig | 11 ++
> > drivers/watchdog/Makefile | 1 +
> > drivers/watchdog/simatic-ipc-wdt.c | 305
> > +++++++++++++++++++++++++++++ 3 files changed, 317 insertions(+)
> > create mode 100644 drivers/watchdog/simatic-ipc-wdt.c
> >
> > diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
> > index 1fe0042a48d2..948497eb4bef 100644
> > --- a/drivers/watchdog/Kconfig
> > +++ b/drivers/watchdog/Kconfig
> > @@ -1575,6 +1575,17 @@ config NIC7018_WDT
> > To compile this driver as a module, choose M here: the
> > module will be
> > called nic7018_wdt.
> >
> > +config SIEMENS_SIMATIC_IPC_WDT
> > + tristate "Siemens Simatic IPC Watchdog"
> > + depends on SIEMENS_SIMATIC_IPC
> > + select WATCHDOG_CORE
> > + help
> > + This driver adds support for several watchdogs found in
> > Industrial
> > + PCs from Siemens.
> > +
> > + To compile this driver as a module, choose M here: the
> > module will be
> > + called simatic-ipc-wdt.
> > +
> > # M68K Architecture
> >
> > config M54xx_WATCHDOG
> > diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile
> > index f3a6540e725e..7f5c73ec058c 100644
> > --- a/drivers/watchdog/Makefile
> > +++ b/drivers/watchdog/Makefile
> > @@ -142,6 +142,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o
> > obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o
> > obj-$(CONFIG_MLX_WDT) += mlx_wdt.o
> > obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o
> > +obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o
> >
> > # M68K Architecture
> > obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o
> > diff --git a/drivers/watchdog/simatic-ipc-wdt.c
> > b/drivers/watchdog/simatic-ipc-wdt.c
> > new file mode 100644
> > index 000000000000..b5c8b7ceb404
> > --- /dev/null
> > +++ b/drivers/watchdog/simatic-ipc-wdt.c
> > @@ -0,0 +1,305 @@
> > +// SPDX-License-Identifier: GPL-2.0
> > +/*
> > + * Siemens SIMATIC IPC driver for Watchdogs
> > + *
> > + * Copyright (c) Siemens AG, 2020-2021
> > + *
> > + * Authors:
> > + * Gerd Haeussler <[email protected]>
> > + *
> > + * This program is free software; you can redistribute it and/or
> > modify
> > + * it under the terms of the GNU General Public License version 2
> > as
> > + * published by the Free Software Foundation.
> > + */
> > +
> > +#include <linux/device.h>
> > +#include <linux/init.h>
> > +#include <linux/kernel.h>
> > +#include <linux/module.h>
> > +#include <linux/platform_device.h>
> > +#include <linux/errno.h>
> > +#include <linux/watchdog.h>
> > +#include <linux/ioport.h>
> > +#include <linux/sizes.h>
> > +#include <linux/io.h>
> > +#include <linux/platform_data/x86/simatic-ipc-base.h>
> > +
> > +#define WD_ENABLE_IOADR 0x62
> > +#define WD_TRIGGER_IOADR 0x66
> > +#define GPIO_COMMUNITY0_PORT_ID 0xaf
> > +#define PAD_CFG_DW0_GPP_A_23 0x4b8
> > +#define SAFE_EN_N_427E 0x01
> > +#define SAFE_EN_N_227E 0x04
> > +#define WD_ENABLED 0x01
> > +
> > +#define TIMEOUT_MIN 2
> > +#define TIMEOUT_DEF 64
> > +#define TIMEOUT_MAX 64
> > +
> > +#define GP_STATUS_REG_227E 0x404D /* IO PORT for SAFE_EN_N on
> > 227E */ +
> > +static bool nowayout = WATCHDOG_NOWAYOUT;
> > +module_param(nowayout, bool, 0000);
> > +MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started
> > (default="
> > + __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
> > +
> > +static DEFINE_SPINLOCK(io_lock); /* the lock for io
> > operations */ +static struct watchdog_device wdd;
> > +
> > +static struct resource gp_status_reg_227e_res =
> > + DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1,
> > KBUILD_MODNAME); +
> > +static struct resource io_resource =
> > + DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
> > + KBUILD_MODNAME " WD_ENABLE_IOADR");
> > +
> > +/* the actual start will be discovered with pci, 0 is a
> > placeholder */ +static struct resource mem_resource =
> > + DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR");
> > +
> > +static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
> > +static void __iomem *wd_reset_base_addr;
> > +
> > +static int get_timeout_idx(u32 timeout)
> > +{
> > + int i;
> > +
> > + i = ARRAY_SIZE(wd_timeout_table) - 1;
> > + for (; i >= 0; i--) {
> > + if (timeout >= wd_timeout_table[i])
> > + break;
> > + }
> > +
> > + return i;
> > +}
> > +
> > +static int wd_start(struct watchdog_device *wdd)
> > +{
> > + u8 regval;
> > +
> > + spin_lock(&io_lock);
> > +
> > + regval = inb(WD_ENABLE_IOADR);
> > + regval |= WD_ENABLED;
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + spin_unlock(&io_lock);
> > +
> > + return 0;
> > +}
> > +
> > +static int wd_stop(struct watchdog_device *wdd)
> > +{
> > + u8 regval;
> > +
> > + spin_lock(&io_lock);
> > +
> > + regval = inb(WD_ENABLE_IOADR);
> > + regval &= ~WD_ENABLED;
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + spin_unlock(&io_lock);
> > +
> > + return 0;
> > +}
> > +
> > +static int wd_ping(struct watchdog_device *wdd)
> > +{
> > + inb(WD_TRIGGER_IOADR);
> > + return 0;
> > +}
> > +
> > +static int wd_set_timeout(struct watchdog_device *wdd, unsigned
> > int t) +{
> > + u8 regval;
> > + int timeout_idx = get_timeout_idx(t);
> > +
> > + spin_lock(&io_lock);
> > +
> > + regval = inb(WD_ENABLE_IOADR) & 0xc7;
> > + regval |= timeout_idx << 3;
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + spin_unlock(&io_lock);
> > + wdd->timeout = wd_timeout_table[timeout_idx];
> > +
> > + return 0;
> > +}
> > +
> > +static const struct watchdog_info wdt_ident = {
> > + .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING |
> > + WDIOF_SETTIMEOUT,
> > + .identity = KBUILD_MODNAME,
> > +};
> > +
> > +static const struct watchdog_ops wdt_ops = {
> > + .owner = THIS_MODULE,
> > + .start = wd_start,
> > + .stop = wd_stop,
> > + .ping = wd_ping,
> > + .set_timeout = wd_set_timeout,
> > +};
> > +
> > +static void wd_set_safe_en_n(u32 wdtmode, bool safe_en_n)
> > +{
> > + u16 resetbit;
> > +
> > + if (wdtmode == SIMATIC_IPC_DEVICE_227E) {
> > + /* enable SAFE_EN_N on GP_STATUS_REG_227E */
> > + resetbit = inw(GP_STATUS_REG_227E);
> > + if (safe_en_n)
> > + resetbit &= ~SAFE_EN_N_227E;
> > + else
> > + resetbit |= SAFE_EN_N_227E;
> > +
> > + outw(resetbit, GP_STATUS_REG_227E);
> > + } else {
> > + /* enable SAFE_EN_N on PCH D1600 */
> > + resetbit = ioread16(wd_reset_base_addr);
> > +
> > + if (safe_en_n)
> > + resetbit &= ~SAFE_EN_N_427E;
> > + else
> > + resetbit |= SAFE_EN_N_427E;
> > +
> > + iowrite16(resetbit, wd_reset_base_addr);
> > + }
> > +}
> > +
> > +static int wd_setup(u32 wdtmode, bool safe_en_n)
> > +{
> > + u8 regval;
> > + int timeout_idx = 0;
> > + bool alarm_active;
> > +
> > + timeout_idx = get_timeout_idx(TIMEOUT_DEF);
> > +
> > + wd_set_safe_en_n(wdtmode, safe_en_n);
> > +
> > + /* read wd register to determine alarm state */
> > + regval = inb(WD_ENABLE_IOADR);
> > + if (regval & 0x80) {
> > + pr_warn("Watchdog alarm active.\n");
> > + regval = 0x82; /* use only macro mode, reset alarm
> > bit */
> > + alarm_active = true;
> > + } else {
> > + regval = 0x02; /* use only macro mode */
> > + alarm_active = false;
> > + }
> > +
> > + regval |= timeout_idx << 3;
> > + if (nowayout)
> > + regval |= WD_ENABLED;
> > +
> > + outb(regval, WD_ENABLE_IOADR);
> > +
> > + return alarm_active;
> > +}
> > +
> > +static int simatic_ipc_wdt_probe(struct platform_device *pdev)
> > +{
> > + struct device *dev = &pdev->dev;
> > + int rc = 0;
> > + struct simatic_ipc_platform *plat = pdev->dev.platform_data;
> > + struct resource *res;
> > +
> > + pr_debug(KBUILD_MODNAME ":%s(#%d) WDT mode: %d\n",
> > + __func__, __LINE__, plat->devmode);
> > +
> > + switch (plat->devmode) {
> > + case SIMATIC_IPC_DEVICE_227E:
> > + if (!devm_request_region(dev,
> > gp_status_reg_227e_res.start,
> > +
> > resource_size(&gp_status_reg_ 227e_res),
> > + KBUILD_MODNAME)) {
> > + dev_err(dev,
> > + "Unable to register IO resource at
> > %pR\n",
> > + &gp_status_reg_227e_res);
> > + return -EBUSY;
> > + }
> > + fallthrough;
> > + case SIMATIC_IPC_DEVICE_427E:
> > + wdd.info = &wdt_ident;
> > + wdd.ops = &wdt_ops;
> > + wdd.min_timeout = TIMEOUT_MIN;
> > + wdd.max_timeout = TIMEOUT_MAX;
> > + wdd.parent = NULL;
> > + break;
> > + default:
> > + return -EINVAL;
> > + }
> > +
> > + if (!devm_request_region(dev, io_resource.start,
> > + resource_size(&io_resource),
> > + io_resource.name)) {
> > + dev_err(dev,
> > + "Unable to register IO resource at %#x\n",
> > + WD_ENABLE_IOADR);
> > + return -EBUSY;
> > + }
> > +
> > + if (plat->devmode == SIMATIC_IPC_DEVICE_427E) {
> > + res = &mem_resource;
> > +
> > + /* get GPIO base from PCI */
> > + res->start =
> > simatic_ipc_get_membase0(PCI_DEVFN(0x1f, 1));
> > + if (res->start == 0)
> > + return -ENODEV;
> > +
> > + /* do the final address calculation */
> > + res->start = res->start + (GPIO_COMMUNITY0_PORT_ID
> > << 16) +
> > + PAD_CFG_DW0_GPP_A_23;
> > + res->end += res->start;
> > +
> > + wd_reset_base_addr = devm_ioremap_resource(dev,
> > res);
> > + if (IS_ERR(wd_reset_base_addr))
> > + return -ENOMEM;
> > + }
> > +
> > + wdd.bootstatus = wd_setup(plat->devmode, true);
> > + if (wdd.bootstatus)
> > + pr_warn(KBUILD_MODNAME ": last reboot caused by
> > watchdog reset\n");
> > +
> > + watchdog_set_nowayout(&wdd, nowayout);
> > + watchdog_stop_on_reboot(&wdd);
> > +
> > + rc = devm_watchdog_register_device(dev, &wdd);
> > +
> > + if (rc == 0)
> > + pr_debug("initialized. nowayout=%d\n",
> > + nowayout);
> > +
> > + return rc;
> > +}
> > +
> > +static int simatic_ipc_wdt_remove(struct platform_device *pdev)
> > +{
> > + struct simatic_ipc_platform *plat = pdev->dev.platform_data;
> > +
> > + wd_setup(plat->devmode, false);
> > + return 0;
> > +}
> > +
> > +static struct platform_driver wdt_driver = {
> > + .probe = simatic_ipc_wdt_probe,
> > + .remove = simatic_ipc_wdt_remove,
> > + .driver = {
> > + .name = KBUILD_MODNAME,
> > + },
> > +};
> > +
> > +static int __init simatic_ipc_wdt_init(void)
> > +{
> > + return platform_driver_register(&wdt_driver);
> > +}
> > +
> > +static void __exit simatic_ipc_wdt_exit(void)
> > +{
> > + platform_driver_unregister(&wdt_driver);
> > +}
> > +
> > +module_init(simatic_ipc_wdt_init);
> > +module_exit(simatic_ipc_wdt_exit);
> > +
> > +MODULE_LICENSE("GPL");
> > +MODULE_ALIAS("platform:" KBUILD_MODNAME);
> > +MODULE_AUTHOR("Gerd Haeussler <[email protected]>");
> > --
> > 2.26.2
> >
> >
>

2021-03-08 15:27:28

by Henning Schild

[permalink] [raw]
Subject: Re: [PATCH 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs

Am Wed, 3 Mar 2021 15:21:05 +0100
schrieb Henning Schild <[email protected]>:

> Hi,
>
> thanks for the fast and thorough review!
>
> Am Tue, 2 Mar 2021 10:38:19 -0800
> schrieb Guenter Roeck <[email protected]>:
>
> > On 3/2/21 8:33 AM, Henning Schild wrote:
> > > From: Henning Schild <[email protected]>
> > >
> > > This driver adds initial support for several devices from Siemens.
> > > It is based on a platform driver introduced in an earlier commit.
> > >
> > > Signed-off-by: Gerd Haeussler <[email protected]>
> > > Signed-off-by: Henning Schild <[email protected]>
> > > ---
> > > drivers/watchdog/Kconfig | 11 ++
> > > drivers/watchdog/Makefile | 1 +
> > > drivers/watchdog/simatic-ipc-wdt.c | 305
> > > +++++++++++++++++++++++++++++ 3 files changed, 317 insertions(+)
> > > create mode 100644 drivers/watchdog/simatic-ipc-wdt.c
> > >
> > > diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
> > > index 1fe0042a48d2..948497eb4bef 100644
> > > --- a/drivers/watchdog/Kconfig
> > > +++ b/drivers/watchdog/Kconfig
> > > @@ -1575,6 +1575,17 @@ config NIC7018_WDT
> > > To compile this driver as a module, choose M here: the
> > > module will be called nic7018_wdt.
> > >
> > > +config SIEMENS_SIMATIC_IPC_WDT
> > > + tristate "Siemens Simatic IPC Watchdog"
> > > + depends on SIEMENS_SIMATIC_IPC
> > > + select WATCHDOG_CORE
> > > + help
> > > + This driver adds support for several watchdogs found in
> > > Industrial
> > > + PCs from Siemens.
> > > +
> > > + To compile this driver as a module, choose M here: the
> > > module will be
> > > + called simatic-ipc-wdt.
> > > +
> > > # M68K Architecture
> > >
> > > config M54xx_WATCHDOG
> > > diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile
> > > index f3a6540e725e..7f5c73ec058c 100644
> > > --- a/drivers/watchdog/Makefile
> > > +++ b/drivers/watchdog/Makefile
> > > @@ -142,6 +142,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o
> > > obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o
> > > obj-$(CONFIG_MLX_WDT) += mlx_wdt.o
> > > obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o
> > > +obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o
> > >
> > > # M68K Architecture
> > > obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o
> > > diff --git a/drivers/watchdog/simatic-ipc-wdt.c
> > > b/drivers/watchdog/simatic-ipc-wdt.c new file mode 100644
> > > index 000000000000..b5c8b7ceb404
> > > --- /dev/null
> > > +++ b/drivers/watchdog/simatic-ipc-wdt.c
> > > @@ -0,0 +1,305 @@
> > > +// SPDX-License-Identifier: GPL-2.0
> > > +/*
> > > + * Siemens SIMATIC IPC driver for Watchdogs
> > > + *
> > > + * Copyright (c) Siemens AG, 2020-2021
> > > + *
> > > + * Authors:
> > > + * Gerd Haeussler <[email protected]>
> > > + *
> > > + * This program is free software; you can redistribute it and/or
> > > modify
> > > + * it under the terms of the GNU General Public License version 2
> > > as
> > > + * published by the Free Software Foundation.
> >
> > Covered by SPDX-License-Identifier
> >
> > > + */
> > > +
> > > +#include <linux/device.h>
> > > +#include <linux/init.h>
> > > +#include <linux/kernel.h>
> > > +#include <linux/module.h>
> > > +#include <linux/platform_device.h>
> > > +#include <linux/errno.h>
> > > +#include <linux/watchdog.h>
> > > +#include <linux/ioport.h>
> > > +#include <linux/sizes.h>> +#include <linux/io.h>
> > > +#include <linux/platform_data/x86/simatic-ipc-base.h>
> >
> > Alphabetic order please
> >
> > > +
> > > +#define WD_ENABLE_IOADR 0x62
> > > +#define WD_TRIGGER_IOADR 0x66
> > > +#define GPIO_COMMUNITY0_PORT_ID 0xaf
> > > +#define PAD_CFG_DW0_GPP_A_23 0x4b8
> >
> > Please increase indentation and spare another tab
> >
> > > +#define SAFE_EN_N_427E 0x01
> > > +#define SAFE_EN_N_227E 0x04
> > > +#define WD_ENABLED 0x01
> > > +
> > > +#define TIMEOUT_MIN 2
> > > +#define TIMEOUT_DEF 64
> > > +#define TIMEOUT_MAX 64
> > > +
> > > +#define GP_STATUS_REG_227E 0x404D /* IO PORT for
> > > SAFE_EN_N on 227E */ +
> > > +static bool nowayout = WATCHDOG_NOWAYOUT;
> > > +module_param(nowayout, bool, 0000);
> > > +MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once
> > > started (default="
> > > + __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
> > > +
> > > +static DEFINE_SPINLOCK(io_lock); /* the lock for io
> > > operations */ +static struct watchdog_device wdd;
> > > +
> >
> > Having two variables named 'wdd' is confusing. Please chose another
> > name.
> >
> > > +static struct resource gp_status_reg_227e_res =
> > > + DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1,
> > > KBUILD_MODNAME); +
> > > +static struct resource io_resource =
> > > + DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
> > > + KBUILD_MODNAME " WD_ENABLE_IOADR");
> > > +
> > > +/* the actual start will be discovered with pci, 0 is a
> > > placeholder */ +static struct resource mem_resource =
> > > + DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR");
> > > +
> > > +static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
> > > +static void __iomem *wd_reset_base_addr;
> > > +
> > > +static int get_timeout_idx(u32 timeout)
> > > +{
> > > + int i;
> > > +
> > > + i = ARRAY_SIZE(wd_timeout_table) - 1;
> > > + for (; i >= 0; i--) {
> > > + if (timeout >= wd_timeout_table[i])
> > > + break;
> > > + }
> > > +
> > > + return i;
> > > +}
> >
> > Please add a comment explaining why you don't use find_closest().
>
> Will not be a comment but we will switch to using this, thanks for
> pointing it out.
>
> > > +
> > > +static int wd_start(struct watchdog_device *wdd)
> > > +{
> > > + u8 regval;
> > > +
> > > + spin_lock(&io_lock);
> > > +
> > The watchdog subsystem already provides locking
> > since the watchdog device can only be opened once.
> >
> > Why is the additional lock needed ?
>
> We had this under internal review and somehow came to the conclusion
> that we "might" need it. I think we will remove it or come back with
> reasons.
>
> > > + regval = inb(WD_ENABLE_IOADR);
> > > + regval |= WD_ENABLED;
> > > + outb(regval, WD_ENABLE_IOADR);
> > > +
> > > + spin_unlock(&io_lock);
> > > +
> > > + return 0;
> > > +}
> > > +
> > > +static int wd_stop(struct watchdog_device *wdd)
> > > +{
> > > + u8 regval;
> > > +
> > > + spin_lock(&io_lock);
> > > +
> > > + regval = inb(WD_ENABLE_IOADR);
> > > + regval &= ~WD_ENABLED;
> > > + outb(regval, WD_ENABLE_IOADR);
> > > +
> > > + spin_unlock(&io_lock);
> > > +
> > > + return 0;
> > > +}
> > > +
> > > +static int wd_ping(struct watchdog_device *wdd)
> > > +{
> > > + inb(WD_TRIGGER_IOADR);
> > > + return 0;
> > > +}
> > > +
> > > +static int wd_set_timeout(struct watchdog_device *wdd, unsigned
> > > int t) +{
> > > + u8 regval;
> > > + int timeout_idx = get_timeout_idx(t);
> > > +
> > > + spin_lock(&io_lock);
> > > +
> > > + regval = inb(WD_ENABLE_IOADR) & 0xc7;
> > > + regval |= timeout_idx << 3;
> > > + outb(regval, WD_ENABLE_IOADR);
> > > +
> > > + spin_unlock(&io_lock);
> > > + wdd->timeout = wd_timeout_table[timeout_idx];
> > > +
> > > + return 0;
> > > +}
> > > +
> > > +static const struct watchdog_info wdt_ident = {
> > > + .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING
> > > |
> > > + WDIOF_SETTIMEOUT,
> > > + .identity = KBUILD_MODNAME,
> > > +};
> > > +
> > > +static const struct watchdog_ops wdt_ops = {
> > > + .owner = THIS_MODULE,
> > > + .start = wd_start,
> > > + .stop = wd_stop,
> > > + .ping = wd_ping,
> > > + .set_timeout = wd_set_timeout,
> > > +};
> > > +
> > > +static void wd_set_safe_en_n(u32 wdtmode, bool safe_en_n)
> > > +{
> > > + u16 resetbit;
> > > +
> > > + if (wdtmode == SIMATIC_IPC_DEVICE_227E) {
> > > + /* enable SAFE_EN_N on GP_STATUS_REG_227E */
> > > + resetbit = inw(GP_STATUS_REG_227E);
> > > + if (safe_en_n)
> > > + resetbit &= ~SAFE_EN_N_227E;
> > > + else
> > > + resetbit |= SAFE_EN_N_227E;
> > > +
> > > + outw(resetbit, GP_STATUS_REG_227E);
> > > + } else {
> > > + /* enable SAFE_EN_N on PCH D1600 */
> > > + resetbit = ioread16(wd_reset_base_addr);
> > > +
> > > + if (safe_en_n)
> > > + resetbit &= ~SAFE_EN_N_427E;
> > > + else
> > > + resetbit |= SAFE_EN_N_427E;
> > > +
> > > + iowrite16(resetbit, wd_reset_base_addr);
> > > + }
> > > +}
> > > +
> > > +static int wd_setup(u32 wdtmode, bool safe_en_n)
> > > +{
> > > + u8 regval;
> > > + int timeout_idx = 0;
> >
> > Unnecessary initialization
> >
> > > + bool alarm_active;
> > > +
> > > + timeout_idx = get_timeout_idx(TIMEOUT_DEF);
> > > +
> > > + wd_set_safe_en_n(wdtmode, safe_en_n);
> > > +
> > > + /* read wd register to determine alarm state */
> > > + regval = inb(WD_ENABLE_IOADR);
> > > + if (regval & 0x80) {
> > > + pr_warn("Watchdog alarm active.\n");
> >
> > Why does that warrant a warning, and what does it mean ? The context
> > suggests that it means the previous reset was caused by the
> > watchdog, but that is not what the message says.
> >
> > > + regval = 0x82; /* use only macro mode,
> > > reset alarm bit */
> > > + alarm_active = true;
> > > + } else {
> > > + regval = 0x02; /* use only macro mode */
> > > + alarm_active = false;
> > > + }
> >
> > Would it hurt to just always write 0x82 ?
> > alarm_active = regval & 0x80;
> > regval = 0x82 | timeout_idx << 3;
> >
> > would be much simpler. Or, if you prefer,
> > alarm_active = !!(regval & 0x80);
> > regval = 0x82 | timeout_idx << 3;
> >
> > Actually, regval isn't even needed in that case.
> > alarm_active = !!(regval & 0x80);
> > outb(0x82 | timeout_idx << 3, WD_ENABLE_IOADR);
> >
> >
> > Either case, please use defines for the bits. WD_ENABLED is already
> > defined, thus the other bits should be set using defines as well.
> >
> > > +
> > > + regval |= timeout_idx << 3;
> > > + if (nowayout)
> > > + regval |= WD_ENABLED;
> >
> > This is not the purpose of nowayout. nowayout prevents stopping
> > the watchdog after it has been started. It is not expected to start
> > the watchdog on boot.
>
> Thanks, that was misunderstood by the author, will fix.
>
> > > +
> > > + outb(regval, WD_ENABLE_IOADR);
> > > +
> > > + return alarm_active;
> > > +}
> > > +
> > > +static int simatic_ipc_wdt_probe(struct platform_device *pdev)
> > > +{
> > > + struct device *dev = &pdev->dev;
> > > + int rc = 0;
> > > + struct simatic_ipc_platform *plat =
> > > pdev->dev.platform_data;
> > > + struct resource *res;
> > > +
> >
> > Is it guaranteed that the device will always be instantiated only
> > once ? If so, how it it guaranteed ?
>
> I suppose if anything did register two platform devices on the
> platform bus this might not be guaranteed. The assumption is that
> simatic-ipc will only ever register one, and the machines always have
> 0-1 "Siemens watchdogs" so at the moment there will never be a need
> for more than one.

Turns out the platform bus would not even allow registering the same
device twice. So it is guaranteed but nobody every attempting it in the
first place, and it never working in the second.

Henning

>
> > Because if there are ever multiple instances the various static
> > variables will cause major trouble (which is why it is always better
> > to not use static variables).
> >
> > > + pr_debug(KBUILD_MODNAME ":%s(#%d) WDT mode: %d\n",
> > > + __func__, __LINE__, plat->devmode);
> > > +
> >
> > This is a platform device. Please use dev_ messages (dev_warn,
> > dev_dbg etc) throughout.
> >
> > > + switch (plat->devmode) {
> > > + case SIMATIC_IPC_DEVICE_227E:
> > > + if (!devm_request_region(dev,
> > > gp_status_reg_227e_res.start,
> > > +
> > > resource_size(&gp_status_reg_227e_res),
> > > + KBUILD_MODNAME)) {
> > > + dev_err(dev,
> > > + "Unable to register IO resource
> > > at %pR\n",
> > > + &gp_status_reg_227e_res);
> > > + return -EBUSY;
> > > + }
> > > + fallthrough;
> > > + case SIMATIC_IPC_DEVICE_427E:
> > > + wdd.info = &wdt_ident;
> > > + wdd.ops = &wdt_ops;
> > > + wdd.min_timeout = TIMEOUT_MIN;
> > > + wdd.max_timeout = TIMEOUT_MAX;
> >
> > Why not use static initialization ?
> >
> > > + wdd.parent = NULL;
> >
> > parent should be the platform device.
> >
> > > + break;
> > > + default:
> > > + return -EINVAL;
> > > + }
> > > +
> > > + if (!devm_request_region(dev, io_resource.start,
> > > + resource_size(&io_resource),
> > > + io_resource.name)) {
> > > + dev_err(dev,
> > > + "Unable to register IO resource at
> > > %#x\n",
> > > + WD_ENABLE_IOADR);
> > > + return -EBUSY;
> > > + }
> >
> > If this is what prevents multiple registrations, it is too late: wdd
> > is already overwritten.
>
> As said, there will be no double-registration.
>
> > > +
> > > + if (plat->devmode == SIMATIC_IPC_DEVICE_427E) {
> > > + res = &mem_resource;
> > > +
> > > + /* get GPIO base from PCI */
> > > + res->start =
> > > simatic_ipc_get_membase0(PCI_DEVFN(0x1f, 1));
> > > + if (res->start == 0)
> > > + return -ENODEV;
> > > +
> > > + /* do the final address calculation */
> > > + res->start = res->start +
> > > (GPIO_COMMUNITY0_PORT_ID << 16) +
> > > + PAD_CFG_DW0_GPP_A_23;
> > > + res->end += res->start;
> > > +
> > > + wd_reset_base_addr = devm_ioremap_resource(dev,
> > > res);
> > > + if (IS_ERR(wd_reset_base_addr))
> > > + return -ENOMEM;
> >
> > return PTR_ERR(wd_reset_base_addr);
> >
> > > + }
> > > +
> > > + wdd.bootstatus = wd_setup(plat->devmode, true);
> >
> > bootstatus does not report a boolean. This translates to
> > WDIOF_OVERHEAT which is almost certainly wrong.
> >
> > > + if (wdd.bootstatus)
> > > + pr_warn(KBUILD_MODNAME ": last reboot caused by
> > > watchdog reset\n");
> >
> > Why two messages ?
> >
> > > +
> > > + watchdog_set_nowayout(&wdd, nowayout);
> > > + watchdog_stop_on_reboot(&wdd);
> > > +
> > > + rc = devm_watchdog_register_device(dev, &wdd);
> > > +
> > Extra empty line not needed
> >
> > > + if (rc == 0)
> > > + pr_debug("initialized. nowayout=%d\n",
> > > + nowayout);
> >
> > What is the value of this message (especially since there is no
> > message if there is an error) ?
> >
> > > +
> > > + return rc;
> > > +}
> > > +
> > > +static int simatic_ipc_wdt_remove(struct platform_device *pdev)
> > > +{
> > > + struct simatic_ipc_platform *plat =
> > > pdev->dev.platform_data; +
> > > + wd_setup(plat->devmode, false);
> >
> > This warrants an explanation. What is the point of updating the
> > timeout here ? And what does SAFE_EN actually do ?
>
> The idea was that module unloading should disable the watchdog, but
> that code will be removed and aligned with other watchdogs.
>
> SAFE_EN is a second enable bit, if it is not set the watchdog will
> fire into the void. Pretty pointless will keep that always armed or
> set it always when toggling "enable".
>
> All the other open points are pretty clear, and will all be dealt with
> in v2.
>
> regards,
> Henning
>
> > The watchdog is stopped on reboot, but this function won't
> > be called in that case, making this call even more questionable.
> > Please document what it does and why it is needed here (but not
> > when rebooting).
> >
> > > + return 0;
> > > +}
> > > +
> > > +static struct platform_driver wdt_driver = {
> > > + .probe = simatic_ipc_wdt_probe,
> > > + .remove = simatic_ipc_wdt_remove,
> > > + .driver = {
> > > + .name = KBUILD_MODNAME,
> > > + },
> > > +};
> > > +
> > > +static int __init simatic_ipc_wdt_init(void)
> > > +{
> > > + return platform_driver_register(&wdt_driver);
> > > +}
> > > +
> > > +static void __exit simatic_ipc_wdt_exit(void)
> > > +{
> > > + platform_driver_unregister(&wdt_driver);
> > > +}
> > > +
> > > +module_init(simatic_ipc_wdt_init);
> > > +module_exit(simatic_ipc_wdt_exit);
> >
> > Why not module_platform_driver() ?
> >
> > > +
> > > +MODULE_LICENSE("GPL");
> > > +MODULE_ALIAS("platform:" KBUILD_MODNAME);
> > > +MODULE_AUTHOR("Gerd Haeussler <[email protected]>");
> > >
> >
>