2021-08-19 12:13:08

by Tang Bin

[permalink] [raw]
Subject: [PATCH] power: supply: cpcap-battery: remove redundant check

In the function cpcap_battery_probe(), the check of '!match->data'
can actually never happen for the driver. First, this probe function
will only be called if there is a match with an entry from the OF
device ID table, and then all entries have .data set to a valid point.
So remove the redundant check.

Co-developed-by: Zhang Shengju <[email protected]>
Signed-off-by: Zhang Shengju <[email protected]>
Signed-off-by: Tang Bin <[email protected]>
---
drivers/power/supply/cpcap-battery.c | 6 ------
1 file changed, 6 deletions(-)

diff --git a/drivers/power/supply/cpcap-battery.c b/drivers/power/supply/cpcap-battery.c
index 8d62d4241..a3866826b 100644
--- a/drivers/power/supply/cpcap-battery.c
+++ b/drivers/power/supply/cpcap-battery.c
@@ -1035,12 +1035,6 @@ static int cpcap_battery_probe(struct platform_device *pdev)
if (!match)
return -EINVAL;

- if (!match->data) {
- dev_err(&pdev->dev, "no configuration data found\n");
-
- return -ENODEV;
- }
-
ddata = devm_kzalloc(&pdev->dev, sizeof(*ddata), GFP_KERNEL);
if (!ddata)
return -ENOMEM;
--
2.20.1.windows.1




2021-09-27 15:48:17

by Sebastian Reichel

[permalink] [raw]
Subject: Re: [PATCH] power: supply: cpcap-battery: remove redundant check

Hi,

On Thu, Aug 19, 2021 at 08:11:37PM +0800, Tang Bin wrote:
> In the function cpcap_battery_probe(), the check of '!match->data'
> can actually never happen for the driver. First, this probe function
> will only be called if there is a match with an entry from the OF
> device ID table, and then all entries have .data set to a valid point.
> So remove the redundant check.
>
> Co-developed-by: Zhang Shengju <[email protected]>
> Signed-off-by: Zhang Shengju <[email protected]>
> Signed-off-by: Tang Bin <[email protected]>
> ---

NAK. Instead replace the complate of_match_device() part. The driver
only needs the data object and there is of_device_get_match_data()
for this. Also - even better - there is a non-DT specific variant
which is device_get_match_data(). Please use that:


const struct cpcap_battery_config *cfg = device_get_match_data(&pdev->dev);
if (!cfg)
return -ENODEV;

memcpy(&ddata->config, cfg, sizeof(ddata->config));

Thanks,

-- Sebastian

> drivers/power/supply/cpcap-battery.c | 6 ------
> 1 file changed, 6 deletions(-)
>
> diff --git a/drivers/power/supply/cpcap-battery.c b/drivers/power/supply/cpcap-battery.c
> index 8d62d4241..a3866826b 100644
> --- a/drivers/power/supply/cpcap-battery.c
> +++ b/drivers/power/supply/cpcap-battery.c
> @@ -1035,12 +1035,6 @@ static int cpcap_battery_probe(struct platform_device *pdev)
> if (!match)
> return -EINVAL;
>
> - if (!match->data) {
> - dev_err(&pdev->dev, "no configuration data found\n");
> -
> - return -ENODEV;
> - }
> -
> ddata = devm_kzalloc(&pdev->dev, sizeof(*ddata), GFP_KERNEL);
> if (!ddata)
> return -ENOMEM;
> --
> 2.20.1.windows.1
>
>
>


Attachments:
(No filename) (1.72 kB)
signature.asc (849.00 B)
Download all attachments

2021-09-28 01:22:52

by Tang Bin

[permalink] [raw]
Subject: Re: [PATCH] power: supply: cpcap-battery: remove redundant check

Hi, Reichel

On 2021/9/27 23:46, Sebastian Reichel wrote:
> NAK. Instead replace the complate of_match_device() part. The driver
> only needs the data object and there is of_device_get_match_data()
> for this. Also - even better - there is a non-DT specific variant
> which is device_get_match_data(). Please use that:
>
>
> const struct cpcap_battery_config *cfg = device_get_match_data(&pdev->dev);
> if (!cfg)
> return -ENODEV;
>
> memcpy(&ddata->config, cfg, sizeof(ddata->config));
>
Got it. Before this patch, I thought it would be better to use
of_device_get_match_data()

to simplify for this place, but your email made me learn it again. I
will send patch v2 for

you.

Thanks

Tang Bin

>
>> drivers/power/supply/cpcap-battery.c | 6 ------
>> 1 file changed, 6 deletions(-)
>>
>> diff --git a/drivers/power/supply/cpcap-battery.c b/drivers/power/supply/cpcap-battery.c
>> index 8d62d4241..a3866826b 100644
>> --- a/drivers/power/supply/cpcap-battery.c
>> +++ b/drivers/power/supply/cpcap-battery.c
>> @@ -1035,12 +1035,6 @@ static int cpcap_battery_probe(struct platform_device *pdev)
>> if (!match)
>> return -EINVAL;
>>
>> - if (!match->data) {
>> - dev_err(&pdev->dev, "no configuration data found\n");
>> -
>> - return -ENODEV;
>> - }
>> -
>> ddata = devm_kzalloc(&pdev->dev, sizeof(*ddata), GFP_KERNEL);
>> if (!ddata)
>> return -ENOMEM;
>> --
>> 2.20.1.windows.1
>>
>>
>>