This mainly implements detection of these devices and will allow
secondary drivers to work on such machines.
The identification is DMI-based with a vendor specific way to tell them
apart in a reliable way.
Drivers for LEDs and Watchdogs will follow to make use of that platform
detection.
Signed-off-by: Henning Schild <[email protected]>
---
drivers/platform/x86/Kconfig | 12 ++
drivers/platform/x86/Makefile | 3 +
drivers/platform/x86/simatic-ipc.c | 168 ++++++++++++++++++
.../platform_data/x86/simatic-ipc-base.h | 29 +++
include/linux/platform_data/x86/simatic-ipc.h | 72 ++++++++
5 files changed, 284 insertions(+)
create mode 100644 drivers/platform/x86/simatic-ipc.c
create mode 100644 include/linux/platform_data/x86/simatic-ipc-base.h
create mode 100644 include/linux/platform_data/x86/simatic-ipc.h
diff --git a/drivers/platform/x86/Kconfig b/drivers/platform/x86/Kconfig
index 7400bc5da5be..a59f3bff5ae1 100644
--- a/drivers/platform/x86/Kconfig
+++ b/drivers/platform/x86/Kconfig
@@ -1075,6 +1075,18 @@ config INTEL_SCU_IPC_UTIL
low level access for debug work and updating the firmware. Say
N unless you will be doing this on an Intel MID platform.
+config SIEMENS_SIMATIC_IPC
+ tristate "Siemens Simatic IPC Class driver"
+ depends on PCI
+ help
+ This Simatic IPC class driver is the central of several drivers. It
+ is mainly used for system identification, after which drivers in other
+ classes will take care of driving specifics of those machines.
+ i.e. LEDs and watchdog.
+
+ To compile this driver as a module, choose M here: the module
+ will be called simatic-ipc.
+
endif # X86_PLATFORM_DEVICES
config PMC_ATOM
diff --git a/drivers/platform/x86/Makefile b/drivers/platform/x86/Makefile
index 219478061683..310d1d2a0886 100644
--- a/drivers/platform/x86/Makefile
+++ b/drivers/platform/x86/Makefile
@@ -123,3 +123,6 @@ obj-$(CONFIG_INTEL_SCU_PLATFORM) += intel_scu_pltdrv.o
obj-$(CONFIG_INTEL_SCU_WDT) += intel_scu_wdt.o
obj-$(CONFIG_INTEL_SCU_IPC_UTIL) += intel_scu_ipcutil.o
obj-$(CONFIG_PMC_ATOM) += pmc_atom.o
+
+# Siemens Simatic Industrial PCs
+obj-$(CONFIG_SIEMENS_SIMATIC_IPC) += simatic-ipc.o
diff --git a/drivers/platform/x86/simatic-ipc.c b/drivers/platform/x86/simatic-ipc.c
new file mode 100644
index 000000000000..3f51fb52150c
--- /dev/null
+++ b/drivers/platform/x86/simatic-ipc.c
@@ -0,0 +1,168 @@
+// SPDX-License-Identifier: GPL-2.0
+/*
+ * Siemens SIMATIC IPC platform driver
+ *
+ * Copyright (c) Siemens AG, 2018-2021
+ *
+ * Authors:
+ * Henning Schild <[email protected]>
+ * Jan Kiszka <[email protected]>
+ * Gerd Haeussler <[email protected]>
+ */
+
+#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
+
+#include <linux/dmi.h>
+#include <linux/kernel.h>
+#include <linux/module.h>
+#include <linux/pci.h>
+#include <linux/platform_data/x86/simatic-ipc.h>
+#include <linux/platform_device.h>
+
+static struct platform_device *ipc_led_platform_device;
+static struct platform_device *ipc_wdt_platform_device;
+
+static const struct dmi_system_id simatic_ipc_whitelist[] = {
+ {
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+ },
+ },
+ {}
+};
+
+static struct simatic_ipc_platform platform_data;
+
+static struct {
+ u32 station_id;
+ u8 led_mode;
+ u8 wdt_mode;
+} device_modes[] = {
+ {SIMATIC_IPC_IPC127E, SIMATIC_IPC_DEVICE_127E, SIMATIC_IPC_DEVICE_NONE},
+ {SIMATIC_IPC_IPC227D, SIMATIC_IPC_DEVICE_227D, SIMATIC_IPC_DEVICE_NONE},
+ {SIMATIC_IPC_IPC227E, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_227E},
+ {SIMATIC_IPC_IPC277E, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_227E},
+ {SIMATIC_IPC_IPC427D, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_NONE},
+ {SIMATIC_IPC_IPC427E, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_427E},
+ {SIMATIC_IPC_IPC477E, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_427E},
+};
+
+static int register_platform_devices(u32 station_id)
+{
+ u8 ledmode = SIMATIC_IPC_DEVICE_NONE;
+ u8 wdtmode = SIMATIC_IPC_DEVICE_NONE;
+ int i;
+
+ platform_data.devmode = SIMATIC_IPC_DEVICE_NONE;
+
+ for (i = 0; i < ARRAY_SIZE(device_modes); i++) {
+ if (device_modes[i].station_id == station_id) {
+ ledmode = device_modes[i].led_mode;
+ wdtmode = device_modes[i].wdt_mode;
+ break;
+ }
+ }
+
+ if (ledmode != SIMATIC_IPC_DEVICE_NONE) {
+ platform_data.devmode = ledmode;
+ ipc_led_platform_device =
+ platform_device_register_data(NULL,
+ KBUILD_MODNAME "_leds", PLATFORM_DEVID_NONE,
+ &platform_data,
+ sizeof(struct simatic_ipc_platform));
+ if (IS_ERR(ipc_led_platform_device))
+ return PTR_ERR(ipc_led_platform_device);
+
+ pr_debug("device=%s created\n",
+ ipc_led_platform_device->name);
+ }
+
+ if (wdtmode != SIMATIC_IPC_DEVICE_NONE) {
+ platform_data.devmode = wdtmode;
+ ipc_wdt_platform_device =
+ platform_device_register_data(NULL,
+ KBUILD_MODNAME "_wdt", PLATFORM_DEVID_NONE,
+ &platform_data,
+ sizeof(struct simatic_ipc_platform));
+ if (IS_ERR(ipc_wdt_platform_device))
+ return PTR_ERR(ipc_wdt_platform_device);
+
+ pr_debug("device=%s created\n",
+ ipc_wdt_platform_device->name);
+ }
+
+ if (ledmode == SIMATIC_IPC_DEVICE_NONE &&
+ wdtmode == SIMATIC_IPC_DEVICE_NONE) {
+ pr_warn("unsupported IPC detected, station id=%08x\n",
+ station_id);
+ return -EINVAL;
+ }
+
+ return 0;
+}
+
+/* FIXME: this should eventually be done with generic P2SB discovery code */
+/*
+ * Get membase address from PCI, used in leds and wdt module. Here we read
+ * the bar0. The final address calculation is done in the appropriate modules
+ */
+u32 simatic_ipc_get_membase0(unsigned int p2sb)
+{
+ struct pci_bus *bus;
+ u32 bar0 = 0;
+ /*
+ * The GPIO memory is in bar0 of the hidden P2SB device.
+ * Unhide the device to have a quick look at it, before we hide it
+ * again.
+ * Also grab the pci rescan lock so that device does not get discovered
+ * and remapped while it is visible.
+ * This code is inspired by drivers/mfd/lpc_ich.c
+ */
+ bus = pci_find_bus(0, 0);
+ pci_lock_rescan_remove();
+ pci_bus_write_config_byte(bus, p2sb, 0xE1, 0x0);
+ pci_bus_read_config_dword(bus, p2sb, PCI_BASE_ADDRESS_0, &bar0);
+
+ bar0 &= ~0xf;
+ pci_bus_write_config_byte(bus, p2sb, 0xE1, 0x1);
+ pci_unlock_rescan_remove();
+
+ return bar0;
+}
+EXPORT_SYMBOL(simatic_ipc_get_membase0);
+
+static int __init simatic_ipc_init_module(void)
+{
+ const struct dmi_system_id *match;
+ u32 station_id;
+ int err;
+
+ match = dmi_first_match(simatic_ipc_whitelist);
+ if (!match)
+ return 0;
+
+ err = dmi_walk(simatic_ipc_find_dmi_entry_helper, &station_id);
+
+ if (err || station_id == SIMATIC_IPC_INVALID_STATION_ID) {
+ pr_warn("DMI entry %d not found\n", SIMATIC_IPC_DMI_ENTRY_OEM);
+ return 0;
+ }
+
+ return register_platform_devices(station_id);
+}
+
+static void __exit simatic_ipc_exit_module(void)
+{
+ platform_device_unregister(ipc_led_platform_device);
+ ipc_led_platform_device = NULL;
+
+ platform_device_unregister(ipc_wdt_platform_device);
+ ipc_wdt_platform_device = NULL;
+}
+
+module_init(simatic_ipc_init_module);
+module_exit(simatic_ipc_exit_module);
+
+MODULE_LICENSE("GPL v2");
+MODULE_AUTHOR("Gerd Haeussler <[email protected]>");
+MODULE_ALIAS("dmi:*:svnSIEMENSAG:*");
diff --git a/include/linux/platform_data/x86/simatic-ipc-base.h b/include/linux/platform_data/x86/simatic-ipc-base.h
new file mode 100644
index 000000000000..62d2bc774067
--- /dev/null
+++ b/include/linux/platform_data/x86/simatic-ipc-base.h
@@ -0,0 +1,29 @@
+/* SPDX-License-Identifier: GPL-2.0 */
+/*
+ * Siemens SIMATIC IPC drivers
+ *
+ * Copyright (c) Siemens AG, 2018-2021
+ *
+ * Authors:
+ * Henning Schild <[email protected]>
+ * Gerd Haeussler <[email protected]>
+ */
+
+#ifndef __PLATFORM_DATA_X86_SIMATIC_IPC_BASE_H
+#define __PLATFORM_DATA_X86_SIMATIC_IPC_BASE_H
+
+#include <linux/types.h>
+
+#define SIMATIC_IPC_DEVICE_NONE 0
+#define SIMATIC_IPC_DEVICE_227D 1
+#define SIMATIC_IPC_DEVICE_427E 2
+#define SIMATIC_IPC_DEVICE_127E 3
+#define SIMATIC_IPC_DEVICE_227E 4
+
+struct simatic_ipc_platform {
+ u8 devmode;
+};
+
+u32 simatic_ipc_get_membase0(unsigned int p2sb);
+
+#endif /* __PLATFORM_DATA_X86_SIMATIC_IPC_BASE_H */
diff --git a/include/linux/platform_data/x86/simatic-ipc.h b/include/linux/platform_data/x86/simatic-ipc.h
new file mode 100644
index 000000000000..f3b76b39776b
--- /dev/null
+++ b/include/linux/platform_data/x86/simatic-ipc.h
@@ -0,0 +1,72 @@
+/* SPDX-License-Identifier: GPL-2.0 */
+/*
+ * Siemens SIMATIC IPC drivers
+ *
+ * Copyright (c) Siemens AG, 2018-2021
+ *
+ * Authors:
+ * Henning Schild <[email protected]>
+ * Gerd Haeussler <[email protected]>
+ */
+
+#ifndef __PLATFORM_DATA_X86_SIMATIC_IPC_H
+#define __PLATFORM_DATA_X86_SIMATIC_IPC_H
+
+#include <linux/dmi.h>
+#include <linux/platform_data/x86/simatic-ipc-base.h>
+
+#define SIMATIC_IPC_DMI_ENTRY_OEM 129
+/* binary type */
+#define SIMATIC_IPC_DMI_TYPE 0xff
+#define SIMATIC_IPC_DMI_GROUP 0x05
+#define SIMATIC_IPC_DMI_ENTRY 0x02
+#define SIMATIC_IPC_DMI_TID 0x02
+
+enum simatic_ipc_station_ids {
+ SIMATIC_IPC_INVALID_STATION_ID = 0,
+ SIMATIC_IPC_IPC227D = 0x00000501,
+ SIMATIC_IPC_IPC427D = 0x00000701,
+ SIMATIC_IPC_IPC227E = 0x00000901,
+ SIMATIC_IPC_IPC277E = 0x00000902,
+ SIMATIC_IPC_IPC427E = 0x00000A01,
+ SIMATIC_IPC_IPC477E = 0x00000A02,
+ SIMATIC_IPC_IPC127E = 0x00000D01,
+};
+
+static inline u32 simatic_ipc_get_station_id(u8 *data, int max_len)
+{
+ struct {
+ u8 type; /* type (0xff = binary) */
+ u8 len; /* len of data entry */
+ u8 group;
+ u8 entry;
+ u8 tid;
+ __le32 station_id; /* station id (LE) */
+ } __packed * data_entry = (void *)data + sizeof(struct dmi_header);
+
+ while ((u8 *)data_entry < data + max_len) {
+ if (data_entry->type == SIMATIC_IPC_DMI_TYPE &&
+ data_entry->len == sizeof(*data_entry) &&
+ data_entry->group == SIMATIC_IPC_DMI_GROUP &&
+ data_entry->entry == SIMATIC_IPC_DMI_ENTRY &&
+ data_entry->tid == SIMATIC_IPC_DMI_TID) {
+ return le32_to_cpu(data_entry->station_id);
+ }
+ data_entry = (void *)((u8 *)(data_entry) + data_entry->len);
+ }
+
+ return SIMATIC_IPC_INVALID_STATION_ID;
+}
+
+static inline void
+simatic_ipc_find_dmi_entry_helper(const struct dmi_header *dh, void *_data)
+{
+ u32 *id = _data;
+
+ if (dh->type != SIMATIC_IPC_DMI_ENTRY_OEM)
+ return;
+
+ *id = simatic_ipc_get_station_id((u8 *)dh, dh->length);
+}
+
+#endif /* __PLATFORM_DATA_X86_SIMATIC_IPC_H */
--
2.32.0