2022-03-02 14:51:17

by Potin Lai

[permalink] [raw]
Subject: [PATCH v5 0/2] hwmon: (adm1275) Add sample averaging binding support

This patch series allow user config PWR_AVG and VI_AVG in PMON_CONF
register by adding properties in device tree.

Example:
adm1278@11 {
compatible = "adi,adm1278";
......
adi,volt-curr-sample-average = <128>;
adi,power-sample-average = <128>;
};

LINK: [v1] https://lore.kernel.org/all/[email protected]/
LINK: [v2] https://lore.kernel.org/all/[email protected]/
LINK: [v3] https://lore.kernel.org/all/[email protected]/
LINK: [v4] https://lore.kernel.org/all/[email protected]/

Changes v4 --> v5:
- remove "adi,power-sample-average-enable" property, just set number of
sampling to 1 as disabling sample averaging, and set 2 .. 128 as
enabling.
- update correct default value (from datasheet) in if-block of each chip,
and set "adi,power-sample-average" to false if not allowed.
- change adm1278 pmon_config smbus write "byte" to "word" in probe,
adm1278 pmon_config register has 2 bytes data length.

Changes v3 --> v4:
- add "adi,power-sample-average-enable" property
- add sample number cehcking in driver, only allow listed value
- remove info logging, add error log when invalid number detected

Changes v2 --> v3:
- change property type back to u32, use logical value instead of register
value
- fix typo in properties description
- add if-block to descript "adi,power-sample-average" not alloed if
compatible not in the enum list

Changes v1 --> v2:
- use more descriptive property name
- change property type from u32 to u8
- add property value check, valid range between 1 and 7

Potin Lai (2):
hwmon: (adm1275) Allow setting sample averaging
dt-bindings: hwmon: Add sample averaging properties for ADM1275

.../bindings/hwmon/adi,adm1275.yaml | 69 +++++++++++++++++++
drivers/hwmon/pmbus/adm1275.c | 40 ++++++++++-
2 files changed, 108 insertions(+), 1 deletion(-)

--
2.17.1


2022-03-02 22:33:07

by Potin Lai

[permalink] [raw]
Subject: [PATCH v5 1/2] hwmon: (adm1275) Allow setting sample averaging

Current driver assume PWR_AVG and VI_AVG as 1 by default, and user needs
to set sample averaging via sysfs manually.

This patch parses the properties "adi,power-sample-average" and
"adi,volt-curr-sample-average" from device tree, and setting sample
averaging during probe. Input value must be one of value in the
list [1, 2, 4, 8, 16, 32, 64, 128].

Signed-off-by: Potin Lai <[email protected]>
---
drivers/hwmon/pmbus/adm1275.c | 40 ++++++++++++++++++++++++++++++++++-
1 file changed, 39 insertions(+), 1 deletion(-)

diff --git a/drivers/hwmon/pmbus/adm1275.c b/drivers/hwmon/pmbus/adm1275.c
index d311e0557401..3b07bfb43e93 100644
--- a/drivers/hwmon/pmbus/adm1275.c
+++ b/drivers/hwmon/pmbus/adm1275.c
@@ -475,6 +475,7 @@ static int adm1275_probe(struct i2c_client *client)
int vindex = -1, voindex = -1, cindex = -1, pindex = -1;
int tindex = -1;
u32 shunt;
+ u32 avg;

if (!i2c_check_functionality(client->adapter,
I2C_FUNC_SMBUS_READ_BYTE_DATA
@@ -687,7 +688,7 @@ static int adm1275_probe(struct i2c_client *client)
if ((config & (ADM1278_VOUT_EN | ADM1278_TEMP1_EN)) !=
(ADM1278_VOUT_EN | ADM1278_TEMP1_EN)) {
config |= ADM1278_VOUT_EN | ADM1278_TEMP1_EN;
- ret = i2c_smbus_write_byte_data(client,
+ ret = i2c_smbus_write_word_data(client,
ADM1275_PMON_CONFIG,
config);
if (ret < 0) {
@@ -756,6 +757,43 @@ static int adm1275_probe(struct i2c_client *client)
return -ENODEV;
}

+ if (data->have_power_sampling &&
+ of_property_read_u32(client->dev.of_node,
+ "adi,power-sample-average", &avg) == 0) {
+ if (!avg || avg > ADM1275_SAMPLES_AVG_MAX ||
+ BIT(__fls(avg)) != avg) {
+ dev_err(&client->dev,
+ "Invalid number of power samples");
+ return -EINVAL;
+ }
+ ret = adm1275_write_pmon_config(data, client, true,
+ ilog2(avg));
+ if (ret < 0) {
+ dev_err(&client->dev,
+ "Setting power sample averaging failed with error %d",
+ ret);
+ return ret;
+ }
+ }
+
+ if (of_property_read_u32(client->dev.of_node,
+ "adi,volt-curr-sample-average", &avg) == 0) {
+ if (!avg || avg > ADM1275_SAMPLES_AVG_MAX ||
+ BIT(__fls(avg)) != avg) {
+ dev_err(&client->dev,
+ "Invalid number of voltage/current samples");
+ return -EINVAL;
+ }
+ ret = adm1275_write_pmon_config(data, client, false,
+ ilog2(avg));
+ if (ret < 0) {
+ dev_err(&client->dev,
+ "Setting voltage and current sample averaging failed with error %d",
+ ret);
+ return ret;
+ }
+ }
+
if (voindex < 0)
voindex = vindex;
if (vindex >= 0) {
--
2.17.1