To discard false readings, one should use "ti,penirq-recheck-delay-usecs".
Checking get_pendown_state() at the beginning, most of the time fails
causing malfunctioning.
Signed-off-by: Luca Ellero <[email protected]>
---
drivers/input/touchscreen/ads7846.c | 8 +-------
1 file changed, 1 insertion(+), 7 deletions(-)
diff --git a/drivers/input/touchscreen/ads7846.c b/drivers/input/touchscreen/ads7846.c
index 9e15cdf6faa0..122d3a13b7c5 100644
--- a/drivers/input/touchscreen/ads7846.c
+++ b/drivers/input/touchscreen/ads7846.c
@@ -843,14 +843,8 @@ static void ads7846_report_state(struct ads7846 *ts)
if (x == MAX_12BIT)
x = 0;
- if (ts->model == 7843) {
+ if (ts->model == 7843 || ts->model == 7845) {
Rt = ts->pressure_max / 2;
- } else if (ts->model == 7845) {
- if (get_pendown_state(ts))
- Rt = ts->pressure_max / 2;
- else
- Rt = 0;
- dev_vdbg(&ts->spi->dev, "x/y: %d/%d, PD %d\n", x, y, Rt);
} else if (likely(x && z1)) {
/* compute touch pressure resistance using equation #2 */
Rt = z2;
--
2.25.1
On Tue, Nov 29, 2022 at 04:19:59PM +0100, Luca Ellero wrote:
> To discard false readings, one should use "ti,penirq-recheck-delay-usecs".
> Checking get_pendown_state() at the beginning, most of the time fails
> causing malfunctioning.
Same comments as per patch 1.
--
With Best Regards,
Andy Shevchenko