Subject: [PATCH v1 1/2] thermal: gov_step_wise: Simplify get_target_state()

From: Rafael J. Wysocki <[email protected]>

The step-wise governor's get_target_state() function contains redundant
braces, redundant parens and a redundant next_target local variable, so
get rid of all that stuff.

No intentional functional impact.

Signed-off-by: Rafael J. Wysocki <[email protected]>
---
drivers/thermal/gov_step_wise.c | 27 ++++++++++-----------------
1 file changed, 10 insertions(+), 17 deletions(-)

Index: linux-pm/drivers/thermal/gov_step_wise.c
===================================================================
--- linux-pm.orig/drivers/thermal/gov_step_wise.c
+++ linux-pm/drivers/thermal/gov_step_wise.c
@@ -32,7 +32,6 @@ static unsigned long get_target_state(st
{
struct thermal_cooling_device *cdev = instance->cdev;
unsigned long cur_state;
- unsigned long next_target;

/*
* We keep this instance the way it is by default.
@@ -40,32 +39,26 @@ static unsigned long get_target_state(st
* cdev in use to determine the next_target.
*/
cdev->ops->get_cur_state(cdev, &cur_state);
- next_target = instance->target;
dev_dbg(&cdev->device, "cur_state=%ld\n", cur_state);

if (!instance->initialized) {
- if (throttle) {
- next_target = clamp((cur_state + 1), instance->lower, instance->upper);
- } else {
- next_target = THERMAL_NO_TARGET;
- }
+ if (throttle)
+ return clamp(cur_state + 1, instance->lower, instance->upper);

- return next_target;
+ return THERMAL_NO_TARGET;
}

if (throttle) {
if (trend == THERMAL_TREND_RAISING)
- next_target = clamp((cur_state + 1), instance->lower, instance->upper);
- } else {
- if (trend == THERMAL_TREND_DROPPING) {
- if (cur_state <= instance->lower)
- next_target = THERMAL_NO_TARGET;
- else
- next_target = clamp((cur_state - 1), instance->lower, instance->upper);
- }
+ return clamp(cur_state + 1, instance->lower, instance->upper);
+ } else if (trend == THERMAL_TREND_DROPPING) {
+ if (cur_state <= instance->lower)
+ return THERMAL_NO_TARGET;
+
+ return clamp(cur_state - 1, instance->lower, instance->upper);
}

- return next_target;
+ return instance->target;
}

static void thermal_zone_trip_update(struct thermal_zone_device *tz,





2024-04-04 11:15:34

by Lukasz Luba

[permalink] [raw]
Subject: Re: [PATCH v1 1/2] thermal: gov_step_wise: Simplify get_target_state()

Hi Rafael,

On 4/3/24 19:11, Rafael J. Wysocki wrote:
> From: Rafael J. Wysocki <[email protected]>
>
> The step-wise governor's get_target_state() function contains redundant
> braces, redundant parens and a redundant next_target local variable, so
> get rid of all that stuff.
>
> No intentional functional impact.
>
> Signed-off-by: Rafael J. Wysocki <[email protected]>
> ---
> drivers/thermal/gov_step_wise.c | 27 ++++++++++-----------------
> 1 file changed, 10 insertions(+), 17 deletions(-)
>
> Index: linux-pm/drivers/thermal/gov_step_wise.c
> ===================================================================
> --- linux-pm.orig/drivers/thermal/gov_step_wise.c
> +++ linux-pm/drivers/thermal/gov_step_wise.c
> @@ -32,7 +32,6 @@ static unsigned long get_target_state(st
> {
> struct thermal_cooling_device *cdev = instance->cdev;
> unsigned long cur_state;
> - unsigned long next_target;
>
> /*
> * We keep this instance the way it is by default.
> @@ -40,32 +39,26 @@ static unsigned long get_target_state(st
> * cdev in use to determine the next_target.
> */
> cdev->ops->get_cur_state(cdev, &cur_state);
> - next_target = instance->target;
> dev_dbg(&cdev->device, "cur_state=%ld\n", cur_state);
>
> if (!instance->initialized) {
> - if (throttle) {
> - next_target = clamp((cur_state + 1), instance->lower, instance->upper);
> - } else {
> - next_target = THERMAL_NO_TARGET;
> - }
> + if (throttle)
> + return clamp(cur_state + 1, instance->lower, instance->upper);
>
> - return next_target;
> + return THERMAL_NO_TARGET;
> }
>
> if (throttle) {
> if (trend == THERMAL_TREND_RAISING)
> - next_target = clamp((cur_state + 1), instance->lower, instance->upper);
> - } else {
> - if (trend == THERMAL_TREND_DROPPING) {
> - if (cur_state <= instance->lower)
> - next_target = THERMAL_NO_TARGET;
> - else
> - next_target = clamp((cur_state - 1), instance->lower, instance->upper);
> - }
> + return clamp(cur_state + 1, instance->lower, instance->upper);
> + } else if (trend == THERMAL_TREND_DROPPING) {
> + if (cur_state <= instance->lower)
> + return THERMAL_NO_TARGET;
> +
> + return clamp(cur_state - 1, instance->lower, instance->upper);
> }
>
> - return next_target;
> + return instance->target;
> }
>
> static void thermal_zone_trip_update(struct thermal_zone_device *tz,
>
>
>

LGTM,

Reviewed-by: Lukasz Luba <[email protected]>

Regards,
Lukasz