Few coefficients use default values multiple of 100, not 1000 (in the
example DTS and in the Linux driver):
moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0: 61400 is not a multiple of 1000
Fixes: bf1fdafdbc61 ("dt-bindings: hwmon: (mr75203) add coefficient properties for the thermal equation")
Signed-off-by: Krzysztof Kozlowski <[email protected]>
---
.../devicetree/bindings/hwmon/moortec,mr75203.yaml | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)
diff --git a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
index ae4f68d4e696..bd67cfee6d19 100644
--- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
+++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
@@ -105,7 +105,7 @@ properties:
G coefficient for temperature equation.
Default for series 5 = 60000
Default for series 6 = 57400
- multipleOf: 1000
+ multipleOf: 100
minimum: 1000
$ref: /schemas/types.yaml#/definitions/uint32
@@ -114,7 +114,7 @@ properties:
H coefficient for temperature equation.
Default for series 5 = 200000
Default for series 6 = 249400
- multipleOf: 1000
+ multipleOf: 100
minimum: 1000
$ref: /schemas/types.yaml#/definitions/uint32
@@ -131,7 +131,7 @@ properties:
J coefficient for temperature equation.
Default for series 5 = -100
Default for series 6 = 0
- multipleOf: 1000
+ multipleOf: 100
maximum: 0
$ref: /schemas/types.yaml#/definitions/int32
--
2.34.1
On 7/12/2023 11:11 AM, Krzysztof Kozlowski wrote:
> Few coefficients use default values multiple of 100, not 1000 (in the
> example DTS and in the Linux driver):
>
> moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0:
> 61400 is not a multiple of 1000
Why isn't multiple of 1000 correct?
According to the Moortec datasheet for the series 6 of the temperature
sensor
the coefficients are:
G = 57.4 (57.4 * 1000 = 57400)
H = 249.4
For series 5 coefficients are:
G = 60 (60 * 1000 = 60000)
H = 200
J = -0.1
> Fixes: bf1fdafdbc61 ("dt-bindings: hwmon: (mr75203) add coefficient
> properties for the thermal equation")
> Signed-off-by: Krzysztof Kozlowski <[email protected]>
> ---
> .../devicetree/bindings/hwmon/moortec,mr75203.yaml | 6 +++---
> 1 file changed, 3 insertions(+), 3 deletions(-)
>
> diff --git
> a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
> b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
> index ae4f68d4e696..bd67cfee6d19 100644
> --- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
> +++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
> @@ -105,7 +105,7 @@ properties:
> G coefficient for temperature equation.
> Default for series 5 = 60000
> Default for series 6 = 57400
> - multipleOf: 1000
> + multipleOf: 100
> minimum: 1000
> $ref: /schemas/types.yaml#/definitions/uint32
>
> @@ -114,7 +114,7 @@ properties:
> H coefficient for temperature equation.
> Default for series 5 = 200000
> Default for series 6 = 249400
> - multipleOf: 1000
> + multipleOf: 100
> minimum: 1000
> $ref: /schemas/types.yaml#/definitions/uint32
>
> @@ -131,7 +131,7 @@ properties:
> J coefficient for temperature equation.
> Default for series 5 = -100
> Default for series 6 = 0
> - multipleOf: 1000
> + multipleOf: 100
> maximum: 0
> $ref: /schemas/types.yaml#/definitions/int32
>
> --
> 2.34.1
>
On 12/07/2023 13:58, Farber, Eliav wrote:
> On 7/12/2023 11:11 AM, Krzysztof Kozlowski wrote:
>> Few coefficients use default values multiple of 100, not 1000 (in the
>> example DTS and in the Linux driver):
>>
>> moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0:
>> 61400 is not a multiple of 1000
>
> Why isn't multiple of 1000 correct?
61400 is not a multiple of 1000, at least not in integers. 61400 is a
multiple of 100.
> According to the Moortec datasheet for the series 6 of the temperature
> sensor
> the coefficients are:
> G = 57.4 (57.4 * 1000 = 57400)
57.4 is not integer. With that approach 1 is also multiple of 1000, because:
G = 1 * 0.001 * 1000.
> H = 249.4
> For series 5 coefficients are:
> G = 60 (60 * 1000 = 60000)
> H = 200
> J = -0.1
Trim the context of replies. No need to quote entire text below.
Best regards,
Krzysztof
On Wed, 12 Jul 2023 10:11:24 +0200, Krzysztof Kozlowski wrote:
> Few coefficients use default values multiple of 100, not 1000 (in the
> example DTS and in the Linux driver):
>
> moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0: 61400 is not a multiple of 1000
>
> Fixes: bf1fdafdbc61 ("dt-bindings: hwmon: (mr75203) add coefficient properties for the thermal equation")
> Signed-off-by: Krzysztof Kozlowski <[email protected]>
> ---
> .../devicetree/bindings/hwmon/moortec,mr75203.yaml | 6 +++---
> 1 file changed, 3 insertions(+), 3 deletions(-)
>
Applied, thanks!