2022-09-16 11:42:35

by Crt Mori

[permalink] [raw]
Subject: [PATCH v4 0/3] iio: temperature: mlx90632: Add powermanagement

From: Crt Mori <[email protected]>

As discussed previously on the group under the
"Controlling device power management from terminal" thread the mlx90632
sensor provides measurement capabilities under sleep_step mode. This
series runtime suspends the unused chip to sleep step mode to save power
but in case of continuous sequential reading it switches to continuous
mode for faster readouts. This value is hardcoded to
MLX90632_MEAS_MAX_TIME (with some buffer) and not user configurable.

The sensor runtime suspension is set to MLX90632_SLEEP_DELAY_MS which is
hardcoded to 3 times as much as MEAS_MAX_TIME.

Changes in v4 (per review comments from Jonathan Cameron):

- Migrate back to devm_pm_runtime_enable and remove the pm_disable function
- Remove pm stuff from remove and also sleep, since when iio device is
not registered also sleep makes no sense.
- Replace use EOPNOTSUPP as per checkpatch suggestion although some drivers
still use ENOTSUPP.
- Change the style of read frequency

Changes in v3 (per review comments from Jonathan Cameron):

- Change the "available" attribute presentation to more recent way
suggested
- Replace devm_pm_runtime_enable with enable and devm_add_action_or_reset
- When suspending device also put it to lower power mode in case there is
dummy regulator
- Use more switch cases instead of if/else

Changes in v2:

- apply review comments from Andy Shevchenko

Crt Mori (3):
iio: temperature: mlx90632 Add runtime powermanagement modes
iio: temperature: mlx90632 Read sampling frequency
iio: temperature: mlx90632 Change return value of sensor measurement
channel

drivers/iio/temperature/mlx90632.c | 402 +++++++++++++++++++++++++----
1 file changed, 347 insertions(+), 55 deletions(-)

--
2.34.1


2022-09-16 11:42:56

by Crt Mori

[permalink] [raw]
Subject: [PATCH v4 1/3] iio: temperature: mlx90632 Add runtime powermanagement modes

From: Crt Mori <[email protected]>

The sensor can operate in lower power modes and even make measurements when
in those lower powered modes. The decision was taken that if measurement
is not requested within 2 seconds the sensor will remain in SLEEP_STEP
power mode, where measurements are triggered on request with setting the
start of measurement bit (SOB). In this mode the measurements are taking
a bit longer because we need to start it and complete it. Currently, in
continuous mode we read ready data and this mode is activated if sensor
measurement is requested within 2 seconds. The suspend timeout is
increased to 6 seconds (instead of 3 before), because that enables more
measurements in lower power mode (SLEEP_STEP), with the lowest refresh
rate (2 seconds).

Signed-off-by: Crt Mori <[email protected]>
---
drivers/iio/temperature/mlx90632.c | 341 ++++++++++++++++++++++++-----
1 file changed, 287 insertions(+), 54 deletions(-)

diff --git a/drivers/iio/temperature/mlx90632.c b/drivers/iio/temperature/mlx90632.c
index 549c0ab5c2be..80497d9bc4e9 100644
--- a/drivers/iio/temperature/mlx90632.c
+++ b/drivers/iio/temperature/mlx90632.c
@@ -6,11 +6,14 @@
*
* Driver for the Melexis MLX90632 I2C 16-bit IR thermopile sensor
*/
+#include <linux/bitfield.h>
#include <linux/delay.h>
+#include <linux/device.h>
#include <linux/err.h>
#include <linux/gpio/consumer.h>
#include <linux/i2c.h>
#include <linux/iopoll.h>
+#include <linux/jiffies.h>
#include <linux/kernel.h>
#include <linux/limits.h>
#include <linux/mod_devicetable.h>
@@ -55,6 +58,12 @@
#define MLX90632_EE_Ha 0x2481 /* Ha customer calib value reg 16bit */
#define MLX90632_EE_Hb 0x2482 /* Hb customer calib value reg 16bit */

+#define MLX90632_EE_MEDICAL_MEAS1 0x24E1 /* Medical measurement 1 16bit */
+#define MLX90632_EE_MEDICAL_MEAS2 0x24E2 /* Medical measurement 2 16bit */
+#define MLX90632_EE_EXTENDED_MEAS1 0x24F1 /* Extended measurement 1 16bit */
+#define MLX90632_EE_EXTENDED_MEAS2 0x24F2 /* Extended measurement 2 16bit */
+#define MLX90632_EE_EXTENDED_MEAS3 0x24F3 /* Extended measurement 3 16bit */
+
/* Register addresses - volatile */
#define MLX90632_REG_I2C_ADDR 0x3000 /* Chip I2C address register */

@@ -62,13 +71,16 @@
#define MLX90632_REG_CONTROL 0x3001 /* Control Register address */
#define MLX90632_CFG_PWR_MASK GENMASK(2, 1) /* PowerMode Mask */
#define MLX90632_CFG_MTYP_MASK GENMASK(8, 4) /* Meas select Mask */
+#define MLX90632_CFG_SOB_MASK BIT(11)

/* PowerModes statuses */
#define MLX90632_PWR_STATUS(ctrl_val) (ctrl_val << 1)
#define MLX90632_PWR_STATUS_HALT MLX90632_PWR_STATUS(0) /* hold */
-#define MLX90632_PWR_STATUS_SLEEP_STEP MLX90632_PWR_STATUS(1) /* sleep step*/
+#define MLX90632_PWR_STATUS_SLEEP_STEP MLX90632_PWR_STATUS(1) /* sleep step */
#define MLX90632_PWR_STATUS_STEP MLX90632_PWR_STATUS(2) /* step */
-#define MLX90632_PWR_STATUS_CONTINUOUS MLX90632_PWR_STATUS(3) /* continuous*/
+#define MLX90632_PWR_STATUS_CONTINUOUS MLX90632_PWR_STATUS(3) /* continuous */
+
+#define MLX90632_EE_RR GENMASK(10, 8) /* Only Refresh Rate bits */

/* Measurement types */
#define MLX90632_MTYP_MEDICAL 0
@@ -116,8 +128,9 @@
#define MLX90632_REF_12 12LL /* ResCtrlRef value of Ch 1 or Ch 2 */
#define MLX90632_REF_3 12LL /* ResCtrlRef value of Channel 3 */
#define MLX90632_MAX_MEAS_NUM 31 /* Maximum measurements in list */
-#define MLX90632_SLEEP_DELAY_MS 3000 /* Autosleep delay */
+#define MLX90632_SLEEP_DELAY_MS 6000 /* Autosleep delay */
#define MLX90632_EXTENDED_LIMIT 27000 /* Extended mode raw value limit */
+#define MLX90632_MEAS_MAX_TIME 2000 /* Max measurement time in ms for the lowest refresh rate */

/**
* struct mlx90632_data - private data for the MLX90632 device
@@ -130,6 +143,9 @@
* @object_ambient_temperature: Ambient temperature at object (might differ of
* the ambient temperature of sensor.
* @regulator: Regulator of the device
+ * @powerstatus: Current POWER status of the device
+ * @interaction_ts: Timestamp of the last temperature read that is used
+ * for power management in jiffies
*/
struct mlx90632_data {
struct i2c_client *client;
@@ -139,6 +155,8 @@ struct mlx90632_data {
u8 mtyp;
u32 object_ambient_temperature;
struct regulator *regulator;
+ int powerstatus;
+ unsigned long interaction_ts;
};

static const struct regmap_range mlx90632_volatile_reg_range[] = {
@@ -158,6 +176,8 @@ static const struct regmap_range mlx90632_read_reg_range[] = {
regmap_reg_range(MLX90632_EE_VERSION, MLX90632_EE_Ka),
regmap_reg_range(MLX90632_EE_CTRL, MLX90632_EE_I2C_ADDR),
regmap_reg_range(MLX90632_EE_Ha, MLX90632_EE_Hb),
+ regmap_reg_range(MLX90632_EE_MEDICAL_MEAS1, MLX90632_EE_MEDICAL_MEAS2),
+ regmap_reg_range(MLX90632_EE_EXTENDED_MEAS1, MLX90632_EE_EXTENDED_MEAS3),
regmap_reg_range(MLX90632_REG_I2C_ADDR, MLX90632_REG_CONTROL),
regmap_reg_range(MLX90632_REG_I2C_CMD, MLX90632_REG_I2C_CMD),
regmap_reg_range(MLX90632_REG_STATUS, MLX90632_REG_STATUS),
@@ -198,16 +218,38 @@ static const struct regmap_config mlx90632_regmap = {

static s32 mlx90632_pwr_set_sleep_step(struct regmap *regmap)
{
- return regmap_update_bits(regmap, MLX90632_REG_CONTROL,
- MLX90632_CFG_PWR_MASK,
- MLX90632_PWR_STATUS_SLEEP_STEP);
+ struct mlx90632_data *data =
+ iio_priv(dev_get_drvdata(regmap_get_device(regmap)));
+ s32 ret;
+
+ if (data->powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP)
+ return 0;
+
+ ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL, MLX90632_CFG_PWR_MASK,
+ MLX90632_PWR_STATUS_SLEEP_STEP);
+ if (ret < 0)
+ return ret;
+
+ data->powerstatus = MLX90632_PWR_STATUS_SLEEP_STEP;
+ return ret;
}

static s32 mlx90632_pwr_continuous(struct regmap *regmap)
{
- return regmap_update_bits(regmap, MLX90632_REG_CONTROL,
- MLX90632_CFG_PWR_MASK,
- MLX90632_PWR_STATUS_CONTINUOUS);
+ struct mlx90632_data *data =
+ iio_priv(dev_get_drvdata(regmap_get_device(regmap)));
+ s32 ret;
+
+ if (data->powerstatus == MLX90632_PWR_STATUS_CONTINUOUS)
+ return 0;
+
+ ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL, MLX90632_CFG_PWR_MASK,
+ MLX90632_PWR_STATUS_CONTINUOUS);
+ if (ret < 0)
+ return ret;
+
+ data->powerstatus = MLX90632_PWR_STATUS_CONTINUOUS;
+ return ret;
}

/**
@@ -219,6 +261,63 @@ static void mlx90632_reset_delay(void)
usleep_range(150, 200);
}

+static int mlx90632_get_measurement_time(struct regmap *regmap, u16 meas)
+{
+ unsigned int reg;
+ int ret;
+
+ ret = regmap_read(regmap, meas, &reg);
+ if (ret < 0)
+ return ret;
+
+ return MLX90632_MEAS_MAX_TIME >> FIELD_GET(MLX90632_EE_RR, reg);
+}
+
+static int mlx90632_calculate_dataset_ready_time(struct mlx90632_data *data)
+{
+ unsigned int refresh_time;
+ int ret;
+
+ if (data->mtyp == MLX90632_MTYP_MEDICAL) {
+ ret = mlx90632_get_measurement_time(data->regmap,
+ MLX90632_EE_MEDICAL_MEAS1);
+ if (ret < 0)
+ return ret;
+
+ refresh_time = ret;
+
+ ret = mlx90632_get_measurement_time(data->regmap,
+ MLX90632_EE_MEDICAL_MEAS2);
+ if (ret < 0)
+ return ret;
+
+ refresh_time += ret;
+ } else {
+ ret = mlx90632_get_measurement_time(data->regmap,
+ MLX90632_EE_EXTENDED_MEAS1);
+ if (ret < 0)
+ return ret;
+
+ refresh_time = ret;
+
+ ret = mlx90632_get_measurement_time(data->regmap,
+ MLX90632_EE_EXTENDED_MEAS2);
+ if (ret < 0)
+ return ret;
+
+ refresh_time += ret;
+
+ ret = mlx90632_get_measurement_time(data->regmap,
+ MLX90632_EE_EXTENDED_MEAS3);
+ if (ret < 0)
+ return ret;
+
+ refresh_time += ret;
+ }
+
+ return refresh_time;
+}
+
/**
* mlx90632_perform_measurement() - Trigger and retrieve current measurement cycle
* @data: pointer to mlx90632_data object containing regmap information
@@ -249,26 +348,75 @@ static int mlx90632_perform_measurement(struct mlx90632_data *data)
return (reg_status & MLX90632_STAT_CYCLE_POS) >> 2;
}

-static int mlx90632_set_meas_type(struct regmap *regmap, u8 type)
+/**
+ * mlx90632_perform_measurement_burst() - Trigger and retrieve current measurement
+ * cycle in step sleep mode
+ * @data: pointer to mlx90632_data object containing regmap information
+ *
+ * Perform a measurement and return 2 as measurement cycle position reported
+ * by sensor. This is a blocking function for amount dependent on the sensor
+ * refresh rate.
+ */
+static int mlx90632_perform_measurement_burst(struct mlx90632_data *data)
{
+ unsigned int reg_status;
int ret;

- if ((type != MLX90632_MTYP_MEDICAL) && (type != MLX90632_MTYP_EXTENDED))
- return -EINVAL;
+ ret = regmap_write_bits(data->regmap, MLX90632_REG_CONTROL,
+ MLX90632_CFG_SOB_MASK, MLX90632_CFG_SOB_MASK);
+ if (ret < 0)
+ return ret;

- ret = regmap_write(regmap, MLX90632_REG_I2C_CMD, MLX90632_RESET_CMD);
+ ret = mlx90632_calculate_dataset_ready_time(data);
+ if (ret < 0)
+ return ret;
+
+ msleep(ret); /* Wait minimum time for dataset to be ready */
+
+ ret = regmap_read_poll_timeout(data->regmap, MLX90632_REG_STATUS,
+ reg_status,
+ (reg_status & MLX90632_STAT_BUSY) == 0,
+ 10000, 100 * 10000);
+ if (ret < 0) {
+ dev_err(&data->client->dev, "data not ready");
+ return -ETIMEDOUT;
+ }
+
+ return 2;
+}
+
+static int mlx90632_set_meas_type(struct mlx90632_data *data, u8 type)
+{
+ int current_powerstatus;
+ int ret;
+
+ if (data->mtyp == type)
+ return 0;
+
+ current_powerstatus = data->powerstatus;
+ ret = mlx90632_pwr_continuous(data->regmap);
+ if (ret < 0)
+ return ret;
+
+ ret = regmap_write(data->regmap, MLX90632_REG_I2C_CMD, MLX90632_RESET_CMD);
if (ret < 0)
return ret;

mlx90632_reset_delay();

- ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL,
+ ret = regmap_update_bits(data->regmap, MLX90632_REG_CONTROL,
(MLX90632_CFG_MTYP_MASK | MLX90632_CFG_PWR_MASK),
(MLX90632_MTYP_STATUS(type) | MLX90632_PWR_STATUS_HALT));
if (ret < 0)
return ret;

- return mlx90632_pwr_continuous(regmap);
+ data->mtyp = type;
+ data->powerstatus = MLX90632_PWR_STATUS_HALT;
+
+ if (current_powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP)
+ return mlx90632_pwr_set_sleep_step(data->regmap);
+
+ return mlx90632_pwr_continuous(data->regmap);
}

static int mlx90632_channel_new_select(int perform_ret, uint8_t *channel_new,
@@ -355,11 +503,30 @@ static int mlx90632_read_all_channel(struct mlx90632_data *data,
s32 ret, measurement;

mutex_lock(&data->lock);
- measurement = mlx90632_perform_measurement(data);
- if (measurement < 0) {
- ret = measurement;
+ ret = mlx90632_set_meas_type(data, MLX90632_MTYP_MEDICAL);
+ if (ret < 0)
+ goto read_unlock;
+
+ switch (data->powerstatus) {
+ case MLX90632_PWR_STATUS_CONTINUOUS:
+ measurement = mlx90632_perform_measurement(data);
+ if (measurement < 0) {
+ ret = measurement;
+ goto read_unlock;
+ }
+ break;
+ case MLX90632_PWR_STATUS_SLEEP_STEP:
+ measurement = mlx90632_perform_measurement_burst(data);
+ if (measurement < 0) {
+ ret = measurement;
+ goto read_unlock;
+ }
+ break;
+ default:
+ ret = -EOPNOTSUPP;
goto read_unlock;
}
+
ret = mlx90632_read_ambient_raw(data->regmap, ambient_new_raw,
ambient_old_raw);
if (ret < 0)
@@ -441,14 +608,20 @@ static int mlx90632_read_all_channel_extended(struct mlx90632_data *data, s16 *o
s32 ret, meas;

mutex_lock(&data->lock);
- ret = mlx90632_set_meas_type(data->regmap, MLX90632_MTYP_EXTENDED);
+ ret = mlx90632_set_meas_type(data, MLX90632_MTYP_EXTENDED);
if (ret < 0)
goto read_unlock;

- ret = read_poll_timeout(mlx90632_perform_measurement, meas, meas == 19,
- 50000, 800000, false, data);
- if (ret != 0)
- goto read_unlock;
+ if (data->powerstatus == MLX90632_PWR_STATUS_CONTINUOUS) {
+ ret = read_poll_timeout(mlx90632_perform_measurement, meas, meas == 19,
+ 50000, 800000, false, data);
+ if (ret)
+ goto read_unlock;
+ } else if (data->powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP) {
+ ret = mlx90632_perform_measurement_burst(data);
+ if (ret < 0)
+ goto read_unlock;
+ }

ret = mlx90632_read_object_raw_extended(data->regmap, object_new_raw);
if (ret < 0)
@@ -457,8 +630,6 @@ static int mlx90632_read_all_channel_extended(struct mlx90632_data *data, s16 *o
ret = mlx90632_read_ambient_raw_extended(data->regmap, ambient_new_raw, ambient_old_raw);

read_unlock:
- (void) mlx90632_set_meas_type(data->regmap, MLX90632_MTYP_MEDICAL);
-
mutex_unlock(&data->lock);
return ret;
}
@@ -743,12 +914,47 @@ static int mlx90632_calc_ambient_dsp105(struct mlx90632_data *data, int *val)
return ret;
}

+/**
+ * mlx90632_pm_interraction_wakeup() - Measure time between user interactions to change powermode
+ * @data: pointer to mlx90632_data object containing interaction_ts information
+ *
+ * Switch to continuous mode when interaction is faster than MLX90632_MEAS_MAX_TIME. Update the
+ * interaction_ts for each function call with the jiffies to enable measurement between function
+ * calls. Initial value of the interaction_ts needs to be set before this function call.
+ */
+static int mlx90632_pm_interraction_wakeup(struct mlx90632_data *data)
+{
+ unsigned long now;
+ int ret;
+
+ now = jiffies;
+ if (time_in_range(now, data->interaction_ts,
+ data->interaction_ts +
+ msecs_to_jiffies(MLX90632_MEAS_MAX_TIME + 100))) {
+ if (data->powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP) {
+ ret = mlx90632_pwr_continuous(data->regmap);
+ if (ret < 0)
+ return ret;
+ }
+ }
+
+ data->interaction_ts = now;
+
+ return 0;
+}
+
static int mlx90632_read_raw(struct iio_dev *indio_dev,
struct iio_chan_spec const *channel, int *val,
int *val2, long mask)
{
struct mlx90632_data *data = iio_priv(indio_dev);
int ret;
+ int cr;
+
+ pm_runtime_get_sync(&data->client->dev);
+ ret = mlx90632_pm_interraction_wakeup(data);
+ if (ret < 0)
+ goto mlx90632_read_raw_pm;

switch (mask) {
case IIO_CHAN_INFO_PROCESSED:
@@ -756,16 +962,22 @@ static int mlx90632_read_raw(struct iio_dev *indio_dev,
case IIO_MOD_TEMP_AMBIENT:
ret = mlx90632_calc_ambient_dsp105(data, val);
if (ret < 0)
- return ret;
- return IIO_VAL_INT;
+ goto mlx90632_read_raw_pm;
+
+ ret = IIO_VAL_INT;
+ break;
case IIO_MOD_TEMP_OBJECT:
ret = mlx90632_calc_object_dsp105(data, val);
if (ret < 0)
- return ret;
- return IIO_VAL_INT;
+ goto mlx90632_read_raw_pm;
+
+ ret = IIO_VAL_INT;
+ break;
default:
- return -EINVAL;
+ ret = -EINVAL;
+ break;
}
+ break;
case IIO_CHAN_INFO_CALIBEMISSIVITY:
if (data->emissivity == 1000) {
*val = 1;
@@ -774,13 +986,21 @@ static int mlx90632_read_raw(struct iio_dev *indio_dev,
*val = 0;
*val2 = data->emissivity * 1000;
}
- return IIO_VAL_INT_PLUS_MICRO;
+ ret = IIO_VAL_INT_PLUS_MICRO;
+ break;
case IIO_CHAN_INFO_CALIBAMBIENT:
*val = data->object_ambient_temperature;
- return IIO_VAL_INT;
+ ret = IIO_VAL_INT;
+ break;
default:
- return -EINVAL;
+ ret = -EINVAL;
+ break;
}
+
+mlx90632_read_raw_pm:
+ pm_runtime_mark_last_busy(&data->client->dev);
+ pm_runtime_put_autosuspend(&data->client->dev);
+ return ret;
}

static int mlx90632_write_raw(struct iio_dev *indio_dev,
@@ -902,6 +1122,7 @@ static int mlx90632_probe(struct i2c_client *client,
mlx90632->client = client;
mlx90632->regmap = regmap;
mlx90632->mtyp = MLX90632_MTYP_MEDICAL;
+ mlx90632->powerstatus = MLX90632_PWR_STATUS_HALT;

mutex_init(&mlx90632->lock);
indio_dev->name = id->name;
@@ -961,16 +1182,19 @@ static int mlx90632_probe(struct i2c_client *client,

mlx90632->emissivity = 1000;
mlx90632->object_ambient_temperature = 25000; /* 25 degrees milliCelsius */
+ mlx90632->interaction_ts = jiffies; /* Set initial value */

- pm_runtime_disable(&client->dev);
+ pm_runtime_get_noresume(&client->dev);
ret = pm_runtime_set_active(&client->dev);
if (ret < 0) {
mlx90632_sleep(mlx90632);
return ret;
}
- pm_runtime_enable(&client->dev);
+
+ devm_pm_runtime_enable(&client->dev);
pm_runtime_set_autosuspend_delay(&client->dev, MLX90632_SLEEP_DELAY_MS);
pm_runtime_use_autosuspend(&client->dev);
+ pm_runtime_put_autosuspend(&client->dev);

return iio_device_register(indio_dev);
}
@@ -978,16 +1202,8 @@ static int mlx90632_probe(struct i2c_client *client,
static int mlx90632_remove(struct i2c_client *client)
{
struct iio_dev *indio_dev = i2c_get_clientdata(client);
- struct mlx90632_data *data = iio_priv(indio_dev);

iio_device_unregister(indio_dev);
-
- pm_runtime_disable(&client->dev);
- pm_runtime_set_suspended(&client->dev);
- pm_runtime_put_noidle(&client->dev);
-
- mlx90632_sleep(data);
-
return 0;
}

@@ -1003,30 +1219,47 @@ static const struct of_device_id mlx90632_of_match[] = {
};
MODULE_DEVICE_TABLE(of, mlx90632_of_match);

-static int __maybe_unused mlx90632_pm_suspend(struct device *dev)
+static int mlx90632_pm_suspend(struct device *dev)
{
- struct iio_dev *indio_dev = i2c_get_clientdata(to_i2c_client(dev));
- struct mlx90632_data *data = iio_priv(indio_dev);
+ struct mlx90632_data *data = iio_priv(dev_get_drvdata(dev));
+ int ret;
+
+ ret = mlx90632_pwr_set_sleep_step(data->regmap);
+ if (ret < 0)
+ return ret;
+
+ ret = regulator_disable(data->regulator);
+ if (ret < 0)
+ dev_err(regmap_get_device(data->regmap),
+ "Failed to disable power regulator: %d\n", ret);

- return mlx90632_sleep(data);
+ return ret;
}

-static int __maybe_unused mlx90632_pm_resume(struct device *dev)
+static int mlx90632_pm_resume(struct device *dev)
{
- struct iio_dev *indio_dev = i2c_get_clientdata(to_i2c_client(dev));
- struct mlx90632_data *data = iio_priv(indio_dev);
+ struct mlx90632_data *data = iio_priv(dev_get_drvdata(dev));

- return mlx90632_wakeup(data);
+ return mlx90632_enable_regulator(data);
}

-static UNIVERSAL_DEV_PM_OPS(mlx90632_pm_ops, mlx90632_pm_suspend,
- mlx90632_pm_resume, NULL);
+static int mlx90632_pm_runtime_suspend(struct device *dev)
+{
+ struct mlx90632_data *data = iio_priv(dev_get_drvdata(dev));
+
+ return mlx90632_pwr_set_sleep_step(data->regmap);
+}
+
+const struct dev_pm_ops mlx90632_pm_ops = {
+ SYSTEM_SLEEP_PM_OPS(mlx90632_pm_suspend, mlx90632_pm_resume)
+ RUNTIME_PM_OPS(mlx90632_pm_runtime_suspend, NULL, NULL)
+};

static struct i2c_driver mlx90632_driver = {
.driver = {
.name = "mlx90632",
.of_match_table = mlx90632_of_match,
- .pm = &mlx90632_pm_ops,
+ .pm = pm_ptr(&mlx90632_pm_ops),
},
.probe = mlx90632_probe,
.remove = mlx90632_remove,
--
2.34.1