2023-09-05 19:48:13

by Jon Hunter

[permalink] [raw]
Subject: Re: [Patch v2 2/2] cpufreq: tegra194: use refclk delta based loop instead of udelay


On 01/09/2023 17:41, Sumit Gupta wrote:
> Use reference clock count based loop instead of "udelay()" for
> sampling of counters to improve the accuracy of re-generated CPU
> frequency. "udelay()" internally calls "WFE" which stops the
> counters and results in bigger delta between the last set freq
> and the re-generated value from counters. The counter sampling
> window used in loop is the minimum number of reference clock
> cycles which is known to give a stable value of CPU frequency.
> The change also helps to reduce the sampling window from "500us"
> to "<50us".
>
> Suggested-by: Antti Miettinen <[email protected]>
> Signed-off-by: Sumit Gupta <[email protected]>
> ---

Same here.

Jon

--
nvpublic