2023-10-18 09:32:18

by Varadarajan Narayanan

[permalink] [raw]
Subject: [PATCH v3 2/8] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll

The set rate and determine rate operations are different between
Stromer and Stromer Plus PLLs. Hence, use stromer plus ops for
ipq_pll_stromer_plus.

Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
Signed-off-by: Kathiravan T <[email protected]>
Signed-off-by: Varadarajan Narayanan <[email protected]>
---
v2: Add Fixes tag
---
drivers/clk/qcom/apss-ipq-pll.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/clk/qcom/apss-ipq-pll.c b/drivers/clk/qcom/apss-ipq-pll.c
index e170331..18c4ffe 100644
--- a/drivers/clk/qcom/apss-ipq-pll.c
+++ b/drivers/clk/qcom/apss-ipq-pll.c
@@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
.fw_name = "xo",
},
.num_parents = 1,
- .ops = &clk_alpha_pll_stromer_ops,
+ .ops = &clk_alpha_pll_stromer_plus_ops,
},
},
};
--
2.7.4


2023-10-18 23:59:56

by Stephen Boyd

[permalink] [raw]
Subject: Re: [PATCH v3 2/8] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll

Quoting Varadarajan Narayanan (2023-10-18 02:29:15)
> The set rate and determine rate operations are different between
> Stromer and Stromer Plus PLLs. Hence, use stromer plus ops for
> ipq_pll_stromer_plus.

What goes wrong if we don't have this patch? Please add that detail to
the commit text.

>
> Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
> Signed-off-by: Kathiravan T <[email protected]>
> Signed-off-by: Varadarajan Narayanan <[email protected]>
> ---

Acked-by: Stephen Boyd <[email protected]>