Hi Mark,
On Fri, Sep 26, 2014 at 3:39 PM, Mark Rutland <[email protected]> wrote:
> On Mon, Sep 22, 2014 at 09:35:03PM +0100, Belisko Marek wrote:
>> Hi Mark,
>>
>> On Mon, Sep 22, 2014 at 1:03 PM, Mark Rutland <[email protected]> wrote:
>> > Hi,
>> >
>> > On Wed, Mar 05, 2014 at 08:52:19PM +0000, Marek Belisko wrote:
>> >> Signed-off-by: Marek Belisko <[email protected]>
>> >> ---
>> >> .../bindings/power_supply/twl4030_madc_battery.txt | 43 ++++++++++++++++++++++
>> >> 1 file changed, 43 insertions(+)
>> >> create mode 100644 Documentation/devicetree/bindings/power_supply/twl4030_madc_battery.txt
>> >>
>> >> diff --git a/Documentation/devicetree/bindings/power_supply/twl4030_madc_battery.txt b/Documentation/devicetree/bindings/power_supply/twl4030_madc_battery.txt
>> >> new file mode 100644
>> >> index 0000000..fd0b6d2
>> >> --- /dev/null
>> >> +++ b/Documentation/devicetree/bindings/power_supply/twl4030_madc_battery.txt
>> >> @@ -0,0 +1,43 @@
>> >> +twl4030_madc_battery
>> >> +
>> >> +Required properties:
>> >> + - compatible : "ti,twl4030-madc-battery"
>> >
>> > I'm rather confused by this; the code seems to have stripped away all
>> > the twl4030 dependencies and this now seems to be a generic ADC battery
>> > status driver. So why does this need to be specific to twl4030?
>> You are right. Also possibly driver name is incorrect :). Better name could be
>> ti, madc-battery.
>
> Ok.
>
>> >
>> >> + - capacity : battery capacity in uAh
>> >
>> > I would make the units explicit in the name; "capacity" can be measured
>> > in many ways.
>> OK capacity_uAh should be fine I believe.
>
> Well, "capacity-uah" to match naming conventions.
OK.
>
>> >
>> >> + - charging-calibration-data : list of voltage(mV):level(%) values
>> >> + for charging calibration (see example)
>> >> + - discharging-calibration-data : list of voltage(mV):level(%) values
>> >> + for discharging calibration (see example)
>> >
>> > Regardless of the prefixing of these property names, the specifics are
>> > unclear to me.
>> Do you suggest to rename it completely or is enough to add "ti, " prefix?
>
> I'm not suggesting prefixing. I'm suggesting that "calibration data"
> could mean a variety of things, so having a more specific name would be
> beneficial.
Charging and discharging data are used for some kind of interpolation
within voltage interval.
So we get volume from ADC and then convert it according
charging/discharging table to some value
which is then useded in various battery properties (status,
charge_now, capacity, time_to_empty_now).
So maybe battery-charging/discharging-calibration-data could be property name?
>
>> > Does this apply to vbat?
>> Yes bat is read and then interpolation algorithm is applied for
>> various power properties.
>> So mapping from voltage to percentage is defined in table.
>> >
>> > Is vbat guaranteed to read in mV?
>> Yes.
>> >
>> > Is any particular order required? The example seems to go be in
>> > descending percentage values.
>> There is done sorting in driver so ordering it's not necessary.
>> >
>> > Is any particular interpolation expected on behalf of the OS, or is this
>> > just an informative set of measurements that hte OS can use as it sees
>> > fit?
>> >
>> >> + - io-channels: Should contain IIO channel specifiers
>> >> + for each element in io-channel-names.
>> >> +- io-channel-names: Should contain the following values:
>> All 3 statements was copied from rx51-battery and documentation is the same.
>> There is not unit for all channels just raw values which are then
>> converted in driver.
>
> I don't understand. How do you figure out the mapping of those raw
> values to sensible units? Surely you need additional information to do
> so?
Yes mapping from raw values is done in driver. Like current read from
iio channel_ichg
is multiplied by 1000 or read from channel_temp is multiplied by 10 to
have proper values for
battery properties.
>
> Mark.
BR,
marek
--