Similar to the 2400 and 2500, the LPC controller has some simple reset
lines that are used by the UART devices.
This is already documented in LPC bindings document.
Signed-off-by: Joel Stanley <[email protected]>
---
drivers/reset/reset-simple.c | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/reset/reset-simple.c b/drivers/reset/reset-simple.c
index 4dda0daf2c6f..361a68314265 100644
--- a/drivers/reset/reset-simple.c
+++ b/drivers/reset/reset-simple.c
@@ -144,6 +144,7 @@ static const struct of_device_id reset_simple_dt_ids[] = {
.data = &reset_simple_active_low },
{ .compatible = "aspeed,ast2400-lpc-reset" },
{ .compatible = "aspeed,ast2500-lpc-reset" },
+ { .compatible = "aspeed,ast2600-lpc-reset" },
{ .compatible = "bitmain,bm1880-reset",
.data = &reset_simple_active_low },
{ .compatible = "brcm,bcm4908-misc-pcie-reset",
--
2.34.1
On Mo, 2022-02-21 at 17:56 +1030, Joel Stanley wrote:
> Similar to the 2400 and 2500, the LPC controller has some simple
> reset
> lines that are used by the UART devices.
>
> This is already documented in LPC bindings document.
>
> Signed-off-by: Joel Stanley <[email protected]>
> ---
> drivers/reset/reset-simple.c | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/drivers/reset/reset-simple.c b/drivers/reset/reset-
> simple.c
> index 4dda0daf2c6f..361a68314265 100644
> --- a/drivers/reset/reset-simple.c
> +++ b/drivers/reset/reset-simple.c
> @@ -144,6 +144,7 @@ static const struct of_device_id
> reset_simple_dt_ids[] = {
> .data = &reset_simple_active_low },
> { .compatible = "aspeed,ast2400-lpc-reset" },
> { .compatible = "aspeed,ast2500-lpc-reset" },
> + { .compatible = "aspeed,ast2600-lpc-reset" },
> { .compatible = "bitmain,bm1880-reset",
> .data = &reset_simple_active_low },
> { .compatible = "brcm,bcm4908-misc-pcie-reset",
Thank you, applied to reset/next.
regards
Philipp