2017-11-15 10:56:47

by Marc Kleine-Budde

[permalink] [raw]
Subject: Re: MCP251x SPI CAN controller on Cavium ThunderX

On 11/14/2017 01:02 PM, Mark Brown wrote:
> On Mon, Nov 13, 2017 at 01:17:42PM -0800, Tim Harvey wrote:
>
>> When a register is read from the mcp251x driver the
>> octeon_spi_do_transfer() gets a spi_message with a single spi_xfer of
>> len=3, a tx_buf, and an rx_buf which I believe is supposed to shift
>> out 3 bytes out MOSI and shift in 3 bytes from MISO where the last
>> byte shifted in would be the response.
>
> No, that will simultaneously transmit and recieve three bytes.

That's what the driver supposed to do.

> If you want to transmit two bytes and then recieve one byte you need
> two xfers, one with a len of 2 and a tx_buf, the other with a len of
> 1 and a rx_buf.
To read a register (mcp251x_read_reg()) the mcp251x does a 3 byte full
duplex transfer. The first byte send is the command (read register) the
second byte the register number the third byte is a dummy. The first 2
bytes received are ignored the 3rd byte is the register contents.

Marc

--
Pengutronix e.K. | Marc Kleine-Budde |
Industrial Linux Solutions | Phone: +49-231-2826-924 |
Vertretung West/Dortmund | Fax: +49-5121-206917-5555 |
Amtsgericht Hildesheim, HRA 2686 | http://www.pengutronix.de |