The set rate and determine rate operations are different between
Stromer and Stromer Plus PLLs. Since the programming sequence is
different, the PLLs dont get configured properly and random,
inexplicable crash/freeze is seen. Hence, use stromer plus ops
for ipq_pll_stromer_plus.
Reviewed-by: Dmitry Baryshkov <[email protected]>
Acked-by: Stephen Boyd <[email protected]>
Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
Signed-off-by: Kathiravan T <[email protected]>
Signed-off-by: Varadarajan Narayanan <[email protected]>
---
v4: Update commit log to include
"What goes wrong if we don't have this patch?"
v2: Add Fixes tag
---
drivers/clk/qcom/apss-ipq-pll.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/qcom/apss-ipq-pll.c b/drivers/clk/qcom/apss-ipq-pll.c
index e170331..18c4ffe 100644
--- a/drivers/clk/qcom/apss-ipq-pll.c
+++ b/drivers/clk/qcom/apss-ipq-pll.c
@@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
.fw_name = "xo",
},
.num_parents = 1,
- .ops = &clk_alpha_pll_stromer_ops,
+ .ops = &clk_alpha_pll_stromer_plus_ops,
},
},
};
--
2.7.4
On 10/20/23 08:19, Varadarajan Narayanan wrote:
> The set rate and determine rate operations are different between
> Stromer and Stromer Plus PLLs. Since the programming sequence is
> different, the PLLs dont get configured properly and random,
> inexplicable crash/freeze is seen. Hence, use stromer plus ops
> for ipq_pll_stromer_plus.
>
> Reviewed-by: Dmitry Baryshkov <[email protected]>
> Acked-by: Stephen Boyd <[email protected]>
> Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
> Signed-off-by: Kathiravan T <[email protected]>
> Signed-off-by: Varadarajan Narayanan <[email protected]>
> ---
Reviewed-by: Konrad Dybcio <[email protected]>
Konrad