Hello,
At the moment, to perform a full extraction of the SDP database of a
device, I first perform a call to
array{uint32} GetRemoteServiceHandles(string address, string match)
with an empty "match" string. It does connect to Public Browse Group,
and returns handles for all the ServiceRecords. I then perform a call
array{byte} GetRemoteServiceRecord(string address, uint32 handle)
for each of these handles, and I get all the data in binary form ti
interpret myself.
1) Is it the right way to do this, or is there a way to get that all at
once?
2) As ServiceRecords are extracted "one at a time", is Bluez connecting
and disconnecting to the device each time? Is there a performance
penalty in doing so? If I understand the output of hcidump well, it does
not close he ACL link each time, but there is a L2CAP
connection/disconnection for each ServiceRecord.
Thanks a lot,
Best Regards
Pierre-Yves
-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bluez-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bluez-devel
Hi Marcel,
Thanks a lot for your kind answer.
Pierre-Yves
Marcel Holtmann wrote:
> Hi Pierre-Yves,
>
>> At the moment, to perform a full extraction of the SDP database of a
>> device, I first perform a call to
>>
>> array{uint32} GetRemoteServiceHandles(string address, string match)
>>
>> with an empty "match" string. It does connect to Public Browse Group,
>> and returns handles for all the ServiceRecords. I then perform a call
>>
>> array{byte} GetRemoteServiceRecord(string address, uint32 handle)
>>
>> for each of these handles, and I get all the data in binary form ti
>> interpret myself.
>>
>>
>> 1) Is it the right way to do this, or is there a way to get that all at
>> once?
>
> that is the way to go.
>
>> 2) As ServiceRecords are extracted "one at a time", is Bluez connecting
>> and disconnecting to the device each time? Is there a performance
>> penalty in doing so? If I understand the output of hcidump well, it does
>> not close he ACL link each time, but there is a L2CAP
>> connection/disconnection for each ServiceRecord.
>
> We should add a disconnect timeout to our SDP session and re-use it, but
> that hasn't been done so far.
>
> Regards
>
> Marcel
>
>
>
> -------------------------------------------------------------------------
> Take Surveys. Earn Cash. Influence the Future of IT
> Join SourceForge.net's Techsay panel and you'll get the chance to share your
> opinions on IT & business topics through brief surveys - and earn cash
> http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
> _______________________________________________
> Bluez-devel mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/bluez-devel
-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bluez-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bluez-devel
Hi Pierre-Yves,
> At the moment, to perform a full extraction of the SDP database of a
> device, I first perform a call to
>
> array{uint32} GetRemoteServiceHandles(string address, string match)
>
> with an empty "match" string. It does connect to Public Browse Group,
> and returns handles for all the ServiceRecords. I then perform a call
>
> array{byte} GetRemoteServiceRecord(string address, uint32 handle)
>
> for each of these handles, and I get all the data in binary form ti
> interpret myself.
>
>
> 1) Is it the right way to do this, or is there a way to get that all at
> once?
that is the way to go.
> 2) As ServiceRecords are extracted "one at a time", is Bluez connecting
> and disconnecting to the device each time? Is there a performance
> penalty in doing so? If I understand the output of hcidump well, it does
> not close he ACL link each time, but there is a L2CAP
> connection/disconnection for each ServiceRecord.
We should add a disconnect timeout to our SDP session and re-use it, but
that hasn't been done so far.
Regards
Marcel
-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bluez-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bluez-devel