Hi Marcel
> > 2) I tried using the test mode commands and I am simulatameously
> > running the hcidump, which prints a unknown command type. I am just
> > presuming that the commands might be working alright , only that
> > hcidump doesn't decipher the test commands. Am i right??
>
> What version of hcidump do you use? Show the undecoded output to us.
>
I am using hcidump ver 1.15.
I am trying to set my dongle for a local loopback test. I try with a
"Enable device under test command"
root]# hcitool cmd 0x06 0x0003
Hci dump output is
< HCI Command: Unknown (0x06|0x0003) plen 0
> HCI Event: Command Complete (0x0e) plen 4
01 03 18 00
I am not getting an error. I try to write the "write loopback method
command" and enable local loopback.
root]# hcitool cmd 0x06 0x0002 0x01
Hci dump output is
< HCI Command: Unknown (0x06|0x0002) plen 1
01
> HCI Event: Command Complete (0x0e) plen 4
01 02 18 11
Status shows 11 which is "HCI unsupported feature". I am using a
version 1.1 anycom-120 usb dongle.
hciconfig -a gives the features as
Features: 0xff 0xff 0x05 0x00 0x00 0x00 0x00 0x00
Is this a problem with the firmware. Do i have to upgrade the
firmware and Can i do it??
I also have another doubt......how can i generate the LMP commands
required for the test mode....as in LMP_test_activate PDU and several
other LMP commands. The test methodology only speaks about the LMP
PDU's. How can i generate these LMP commands for the test scenarios.
Thanks,
Best Regards,
Manjunath.
-------------------------------------------------------
SF email is sponsored by - The IT Product Guide
Read honest & candid reviews on hundreds of IT Products from real users.
Discover which products truly live up to the hype. Start reading now.
http://productguide.itmanagersjournal.com/
_______________________________________________
Bluez-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bluez-users