2024-05-09 08:08:39

by Gabor Juhos

[permalink] [raw]
Subject: [PATCH] clk: qcom: apss-ipq-pll: remove 'config_ctl_hi_val' from Stromer pll configs

Since the CONFIG_CTL register is only 32 bits wide in the Stromer
and Stromer Plus PLLs , the 'config_ctl_hi_val' values from the
IPQ5018 and IPQ5332 configurations are not used so remove those.

No functional changes.

Signed-off-by: Gabor Juhos <[email protected]>
---
Based on 'qcom-clk-for-6.10'
---
drivers/clk/qcom/apss-ipq-pll.c | 2 --
1 file changed, 2 deletions(-)

diff --git a/drivers/clk/qcom/apss-ipq-pll.c b/drivers/clk/qcom/apss-ipq-pll.c
index 5f7f537e4ecb..e8632db2c542 100644
--- a/drivers/clk/qcom/apss-ipq-pll.c
+++ b/drivers/clk/qcom/apss-ipq-pll.c
@@ -70,7 +70,6 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
static const struct alpha_pll_config ipq5018_pll_config = {
.l = 0x2a,
.config_ctl_val = 0x4001075b,
- .config_ctl_hi_val = 0x304,
.main_output_mask = BIT(0),
.aux_output_mask = BIT(1),
.early_output_mask = BIT(3),
@@ -84,7 +83,6 @@ static const struct alpha_pll_config ipq5018_pll_config = {
static const struct alpha_pll_config ipq5332_pll_config = {
.l = 0x2d,
.config_ctl_val = 0x4001075b,
- .config_ctl_hi_val = 0x304,
.main_output_mask = BIT(0),
.aux_output_mask = BIT(1),
.early_output_mask = BIT(3),

---
base-commit: 3c5b3e17b8fd1f1add5a9477306c355fab126977
change-id: 20240509-stromer-config-ctl-8cee8e857e13

Best regards,
--
Gabor Juhos <[email protected]>